FDA Adverse Event Malfunction Summary report: N

CB030, 5MMX35CM EPIX LAPA SCISSOR, 10/BX

MDR report key: 13674079 · Received March 4, 2022

Report

Report Number
2027111-2022-00441
Event Type
Malfunction
Date Received
March 4, 2022
Date of Event
February 7, 2022
Report Date
May 23, 2022
Manufacturer
APPLIED MEDICAL RESOURCES
Product Code
HET
UDI-DI
00607915110123
PMA / PMN Number
K062169
Removal / Correction Number
NA
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
BE
Reporter Occupation
PHYSICIAN
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

THE EVENT DEVICE IS ANTICIPATED TO RETURN. A FOLLOW-UP REPORT WILL BE PROVIDED UPON COMPLETION OF THE INVESTIGATION.

Additional Manufacturer Narrative · 0

THE EVENT UNIT WAS RETURNED TO APPLIED MEDICAL FOR EVALUATION. TESTING WAS PERFORMED ON THE EVENT UNIT, WHICH CONFIRMED THAT THE RETURNED UNIT WAS UNABLE TO CUT CONSISTENTLY ACROSS THE ENTIRE LENGTH OF THE BLADE. ENGINEERING OBSERVED A SMALL GAP BETWEEN THE TIPS OF THE BLADES. BASED ON THE CONDITION OF THE EVENT UNIT AND DESCRIPTION OF THE EVENT, THE SCISSORS WERE UNABLE TO CUT DUE TO THE GAP THAT WERE OBSERVED BETWEEN THE TIPS OF THE BLADES ON THE RETURNED UNIT.  HOWEVER, THE EXACT ROOT CAUSE OF THE GAP COULD NOT BE DETERMINED BASED ON THE EVALUATION OF THE RETURNED UNIT. APPLIED MEDICAL CONTINUOUSLY SEEKS TO IMPROVE THE FORM, FUNCTION, AND EASE OF USE OF ITS PRODUCTS.  AS PART OF THIS PROCESS, APPLIED MEDICAL IS CURRENTLY RESEARCHING POSSIBLE ENHANCEMENTS INTENDED TO FURTHER MINIMIZE THE POTENTIAL FOR THIS TYPE OF EVENT TO OCCUR.

Description of Event or Problem · 0

NAME OF PROCEDURE BEING PERFORMED: INGUINAL HERNIA . DETAILED DESCRIPTION OF EVENT: SCISSORS NOT SHARP AT THE DISTAL END WHICH MAKES DISSECTION DURING PROCEDURE MORE DANGEROUS. THIS IS A RETURNING PROBLEM FOR DR [NAME] AND WAS REPORTED IN AN EARLIER CER: 2021-000813 (MFR 2027111-2021-00437), 2021-000814 (MFR 2027111-2021-00438), 2021-000815 (MFR 2027111-2021-00439). UNTIL NOW NO PATIENT WAS HARMED. ADDITIONAL INFORMATION RECEIVED FROM APPLIED MEDICAL REPRESENTATIVE VIA EMAIL ON 11-FEB-2022: UNTIL NOW NO PATIENT INJURY OCCURRED. ADDITIONAL INFORMATION RECEIVED FROM APPLIED MEDICAL REPRESENTATIVE VIA EMAIL ON 23-FEB-2022: NO PATIENT WAS INJURED. PATIENT STATUS: NO PATIENT INJURY.

Description of Event or Problem · 0

NAME OF PROCEDURE BEING PERFORMED: INGUINAL HERNIA. DETAILED DESCRIPTION OF EVENT: SCISSORS NOT SHARP AT THE DISTAL END WHICH MAKES DISSECTION DURING PROCEDURE MORE DANGEROUS. THIS IS A RETURNING PROBLEM FOR DR [NAME] AND WAS REPORTED IN AN EARLIER CER: (B)(4) (MFR 2027111-2021-00437), (B)(4) (MFR 2027111-2021-00438), (B)(4) (MFR 2027111-2021-00439). UNTIL NOW NO PATIENT WAS HARMED. ADDITIONAL INFORMATION RECEIVED FROM APPLIED MEDICAL REPRESENTATIVE VIA EMAIL ON 11-FEB-2022: UNTIL NOW NO PATIENT INJURY OCCURRED. ADDITIONAL INFORMATION RECEIVED FROM APPLIED MEDICAL REPRESENTATIVE VIA EMAIL ON 23-FEB-2022: NO PATIENT WAS INJURED. PATIENT STATUS: NO PATIENT INJURY.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1030447 CB030, 5MMX35CM EPIX LAPA SCISSOR, 10/BX LAPAROSCOPE, GYNECOLOGIC (AND ACCESSORIES) HET APPLIED MEDICAL RESOURCES CB030 1435498 00607915110123

Patients

Seq Age Sex Outcome Treatment
1 Unknown