INSTRUMENT MANAGER SOFTWARE
Report
- Report Number
- 1225673-2009-00001
- Event Type
- Malfunction
- Date Received
- February 20, 2009
- Date of Event
- January 20, 2009
- Report Date
- February 18, 2009
- Manufacturer
- DATA INNOVATIONS, INC.
- Product Code
- JQP
- PMA / PMN Number
- BK080052
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- IL, US
- Reporter Occupation
- OTHER HEALTH CARE PROFESSIONAL
Narratives
ACTIONS TAKEN: SITE REPORTING THE PROBLEM HAS BEEN CONTACTED WITH INFORMATION ABOUT THE ISSUE, AND INFORMED OF THE TEMPORARY SOLUTION TO USE TO PREVENT THE PROBLEM. OTHER CUSTOMERS WHO MAY BE AFFECTED HAVE BEEN NOTIFIED OF THE ISSUE AND TEMPORARY SOLUTION. WORK ON THE PATCH OF SOFTWARE HAS BEGUN. ACTIONS TO BE TAKEN: A LETTER DESCRIBING THIS ISSUE AND RESOLUTION WILL BE SENT TO THE CUSTOMER BASE AFFECTED BY THIS ISSUE. THE SOFTWARE PATCH WILL BE MADE AVAILABLE FOR DOWNLOAD FROM OUR WEBSITE, AS PER OUR ESTABLISHED PROCEDURES. DATA INNOVATIONS WILL ASSIST ANY CUSTOMER WITH QUESTIONS OR NEEDING ASSISTANCE WITH APPLYING THE PATCH. EVAL SUMMARY: THE SITE REPORTING THIS ISSUE TO DATA INNOVATIONS DISCOVERED IT WHEN MANUALLY RE-RUNNING TESTS BUT NOT HAVING THOSE MANUALLY RE-RUN TESTS SUBSEQUENTLY BE HELD BY THE RULE THAT THEY WROTE IN THE INSTRUMENT MANAGER SOFTWARE. THE INSTRUMENT MANAGER SOFTWARE WAS NOT RETURNED TO US, BUT DATA INNOVATIONS EVALUATED DATA RETURNED TO US BY THE SITE REPORTING THE ISSUE. SPECIFICALLY, COMMUNICATIONS TRACE, SPECIMEN EVENT LOG, AUDIT TRAIL AND SPECIMEN TRACKING INFORMATION WAS GATHERED FROM THE SITE. REVIEW OF THIS INFORMATION ASSISTED IN THE INVESTIGATION OF THE PROBLEM AS REPORTED BY THE SITE. AFTER INVESTIGATION, IT WAS POSSIBLE TO REPRODUCE THE PROBLEM AT DATA INNOVATIONS AND THE CAUSE OF THE PROBLEM WAS IDENTIFIED. THE INVESTIGATION ALSO FOUND A METHOD OF OPERATION THAT WILL ENSURE THAT THIS ISSUE DOES NOT RECUR FOR SITES. THIS TEMPORARY WORK AROUND WAS COMMUNICATED TO CUSTOMERS UNTIL SUCH TIME AS A SOFTWARE PATCH CAN BE RELEASED.
ISSUE: THE 'ANY TEST IS RERUN' DATA ELEMENT MAY NOT TRIGGER A RULE TO FIRE EVEN THOUGH A TEST IS MARKED AS A RERUN IN THE DATABASE. ISSUE DETAILS: THE 'ANY TEST IS RERUN' DATA ELEMENT MAY NOT PROPERLY EVALUATE A TEST AS BEING MARKED AS A RERUN IN THE SM DATABASE. THIS PROBLEM WILL MANIFEST ITSELF DEPENDING ON THE ORDER IN WHICH RESULTS ARE RECEIVED FROM THE INSTRUMENT AND THE ORDER IN WHICH THE TESTS WERE ADDED TO THE SM DATABASE. FOR THIS REASON, THE PROBLEM IS MORE LIKELY TO OCCUR THAN NOT.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1 | INSTRUMENT MANAGER SOFTWARE | JQP CALCULATOR/DATA PROCESSING MODULE | JQP | DATA INNOVATIONS, INC. |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 |