FDA Adverse Event Malfunction Summary report: N

BD INSULIN SYRINGES WITH BD ULTRA-FINE¿ 8MM X 31G NEEDLE

MDR report key: 13387385 · Received January 28, 2022

Report

Report Number
1920898-2022-00045
Event Type
Malfunction
Date Received
January 28, 2022
Date of Event
January 11, 2022
Report Date
February 25, 2022
Manufacturer
BD MEDICAL - DIABETES CARE
Product Code
FMF
PMA / PMN Number
NA
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
KS
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

DATE OF EVENT: UNKNOWN. THE DATE RECEIVED BY MANUFACTURER HAS BEEN USED FOR THIS FIELD. A DEVICE EVALUATION IS ANTICIPATED, BUT HAS NOT YET BEGUN. UPON COMPLETION OF THE INVESTIGATION, A SUPPLEMENTAL REPORT WILL BE FILED.

Additional Manufacturer Narrative · 0

H6: INVESTIGATION: CUSTOMER RETURNED (10) 0.3ML BD INSULIN SYRINGES FROM LOT# 1011576. THE CUSTOMER REPORTED THAT THE VERY FIRST SCALE MARK IS LOWER THAN IT SHOULD BE, AND IT IS DIFFICULT TO MEASURE THE EXACT AMOUNT OF DRUG INJECTION. THE RETURNED SYRINGES WERE EXAMINED, AND IT WAS OBSERVED THAT 1 SYRINGE WAS MISSING A 0-UNIT SCALE MARKING. THE REMAINING SYRINGES WERE TESTED USING A 0.3ML PLUG GAUGE, AND IT WAS OBSERVED THAT THE LEADING EDGE OF 1 SYRINGE DID NOT FALL WITHIN THE PLUG GAUGE SPEC. A REVIEW OF THE DEVICE HISTORY RECORD WAS COMPLETED FOR BATCH# 1011576. ALL INSPECTIONS AND CHALLENGES WERE PERFORMED PER THE APPLICABLE OPERATIONS QC SPECIFICATIONS. THERE WAS ONE (1) NOTIFICATION NOTED FOR SCRATCHED PRINT. THERE WERE TWO (2) NOTIFICATIONS NOTED THAT DID NOT PERTAIN TO THE COMPLAINT. ROOT CAUSE COULD NOT BE DETERMINED.

Description of Event or Problem · 0

IT WAS REPORTED THAT 10 BD INSULIN SYRINGES WITH BD ULTRA-FINE¿ 8MM X 31G NEEDLE EXPERIENCED SCALE MARKING ISSUES. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: THE VERY FIRST SCALE MARK (ZERO POINT) IS LOWER THAN IT SHOULD BE AND IT IS DIFFICULT TO MEASURE THE EXACT AMOUNT OF DRUG INJECTION. EVEN THOUGH THE PRODUCTS ARE IN THE SAME BOX, THE POSITION OF THE SCALE MARKS IS DIFFERENT.

Description of Event or Problem · 0

IT WAS REPORTED THAT 10 BD INSULIN SYRINGES WITH BD ULTRA-FINE¿ 8MM X 31G NEEDLE EXPERIENCED SCALE MARKING ISSUES. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: THE VERY FIRST SCALE MARK (ZERO POINT) IS LOWER THAN IT SHOULD BE AND IT IS DIFFICULT TO MEASURE THE EXACT AMOUNT OF DRUG INJECTION. EVEN THOUGH THE PRODUCTS ARE IN THE SAME BOX, THE POSITION OF THE SCALE MARKS IS DIFFERENT.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
762816 BD INSULIN SYRINGES WITH BD ULTRA-FINE¿ 8MM X 31G NEEDLE PISTON SYRINGE FMF BD MEDICAL - DIABETES CARE 1011576

Patients

Seq Age Sex Outcome Treatment
1 Unknown