FDA Adverse Event Malfunction Summary report: N

ARCHITECT C4000

MDR report key: 13315534 · Received January 21, 2022

Report

Report Number
3016438761-2022-00034
Event Type
Malfunction
Date Received
January 21, 2022
Date of Event
December 28, 2021
Report Date
February 17, 2022
Manufacturer
ABBOTT LABORATORIES
Product Code
JJE
UDI-DI
00380740003753
PMA / PMN Number
EXEMPT
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
CA, US
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

THERE WAS NO FURTHER PATIENT INFORMATION PROVIDED BY THE CUSTOMER. AN EVALUATION IS IN PROCESS. A FOLLOW-UP REPORT WILL BE SUBMITTED WHEN THE EVALUATION IS COMPLETE.

Additional Manufacturer Narrative · 0

DURING SITE VISIT BY ABBOTT FIELD SERVICE (FSR), THE FIELD SERVICE REPRESENTATIVE (FSR) INSPECTED THE ANALYZER AND PERFORMED EXTENSIVE TROUBLESHOOTING, AND REPLACED MULTIPLE PARTS TO RESOLVE THE ISSUE. DETERMINED THE JOINT, TBG, REAGENT ARMS (ROHS) (2-89233-02) THE LIKELY CAUSES OF THE ISSUE. THE FOLLOWING PARTS 2-89055-02 BELLOWS SET ,INCL ROD & FITTING (ROHS), 09D41-03 1ML SYRINGE, 7-205228-02 NOZZLE C4 #1, #4, #5 (ROHS), 7-93136-02 MANIFOLD, DI TO CUV WASH (ROHS) REPLACEMENT WHICH RESOLVED THE ISSUE. A REVIEW OF THE ANALYZER SERVICE HISTORY IDENTIFIED NO CONTRIBUTING FACTORS TO THE CURRENT COMPLAINT. A REVIEW OF TRACKING AND TRENDING OF THE ARCHITECT C4000 PROCESSING MODULE OR THE PARTS, DID NOT IDENTIFY ANY TRENDS ASSOCIATED WITH THE COMPLAINT ISSUE. A REVIEW OF HISTORICAL DATA REVEALED NO TRENDS, SYSTEMIC ISSUES, OR RELATED NONCONFORMANCES. THE ARCHITECT OPERATIONS MANUAL ALSO ADDRESSES TROUBLESHOOTING OF DESCREPANT AND ERRATIC SAMPLE RESULTS. THE ARCHITECT C4000 SYSTEMS SERVICE AND SUPPORT MANUAL, PROVIDES REMOVAL AND REPLACEMENT PROCEDURES FOR THE ASSOCIATED PARTS. A REVIEW OF THE PRODUCT LABELING CONCLUDED THAT THE ISSUE IS SUFFICIENTLY ADDRESSED. BASED ON THE INVESTIGATION NO PRODUCT DEFICIENCY WAS IDENTIFIED FOR EITHER THE ARCHITECT C4000 PROCESSING MODULE, SERIAL NUMBER (B)(6), OR THE 2-89055-02 BELLOWS SET ,INCL ROD & FITTING (ROHS), 09D41-03 1ML SYRINGE, 7-205228-02 NOZZLE C4 #1, #4, #5 (ROHS), 7-93136-02 MANIFOLD, DI TO CUV WASH (ROHS).

Description of Event or Problem · 0

THE CUSTOMER OBSERVED FALSELY ELEVATED MAGNESIUM ON ARCHITECT C4000 PROCESSING MODULE FOR ONE PATIENT. THE RESULTS PROVIDED WERE: ON (B)(6) 2021 SID (B)(6) INITIAL=9.0 MG/DL /REPEATED ON ANOTHER ABBOTT ANALYZER=2.5 MG/DL LABORATORY NORMAL RANGE FOR MAGNESIUM=1.6 TO 2.6MG/DL; CRITICAL VALUES < 1 MG/DL AND > 4.5 MG/DL THERE WAS NO REPORTED IMPACT TO PATIENT MANAGEMENT.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
960840 ARCHITECT C4000 ANALYZER, CHEMISTRY (PHOTOMETRIC, DISCRETE), FOR CLINICAL USE JJE ABBOTT LABORATORIES 2P24-40 00380740003753

Patients

Seq Age Sex Outcome Treatment
1 Unknown CC MAGNESIUM(1000T), 03P68-22, 47394UN21| CC MAGNESIUM(1000T), 03P68-22, 47394UN21