STENT - VASCULAR RECONSTRUCTION
Report
- Report Number
- 3008114965-2021-00721
- Event Type
- Injury
- Date Received
- December 17, 2021
- Date of Event
- May 14, 2018
- Report Date
- December 17, 2021
- Manufacturer
- MEDOS INTERNATIONAL SARL
- Product Code
- NJE
- PMA / PMN Number
- H60001
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Occupation
- OTHER HEALTH CARE PROFESSIONAL
- Health Professional
- Yes
Narratives
(B)(4). THIS COMPLAINT IS FROM A LITERATURE SOURCE AND THE FOLLOWING CITATION WAS REVIEWED: FORBRIG R, LOCKAU H, FLOTTMANN F, BOECKH-BEHRENS T, KABBASCH C, PATZIG M, MPOTSARIS A, FIEHLER J, LIEBIG T, THOMALLA G, ONUR OA, WUNDERLICH S, KREISER K, HERZBERG M, WOLLENWEBER FA, PROTHMANN S, DORN F. INTRACRANIAL RESCUE STENT ANGIOPLASTY AFTER STENT-RETRIEVER THROMBECTOMY : MULTICENTER EXPERIENCE. CLIN NEURORADIOL. 2019 SEP;29(3):445-457. DOI: 10.1007/S00062-018-0690-4. EPUB 2018 MAY 14. PMID: 29761219. THE PRODUCT CATALOG AND LOT NUMBERS ARE NOT AVAILABLE / NOT REPORTED. THE UNIQUE IDENTIFIER (UDI) AND EXPIRATION DATE OF THE DEVICE IS NOT KNOWN. THE INITIAL REPORTER PHONE IS NOT AVAILABLE. THE DEVICE MANUFACTURE DATE IS NOT KNOWN AS THE DEVICE LOT NUMBER IS NOT AVAILABLE / NOT REPORTED. DUE TO THE NATURE OF THE COMPLAINT, THE DEVICE (S) WERE NOT RETURNED FOR ANALYSIS NOR WAS THE STERILE LOT NUMBERS PROVIDED IN ORDER TO CONDUCT A LOT HISTORY REVIEW. AS A RESULT, WE ARE CLOSING THIS INVESTIGATION. IF THE COMPLAINT DEVICE IS RECEIVED IN THE FUTURE, WE WILL REOPEN THE COMPLAINT AND PERFORM THE INVESTIGATION AS APPROPRIATE. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL REPORT, A FOLLOW-UP REPORT WILL BE FILED AS APPROPRIATE. MISSING INFORMATION FROM THIS REPORT IS IDENTIFIED AS BLANK; THIS INFORMATION WAS NOT PROVIDED IN THE REPORTED EVENT OR AVAILABLE AT THE TIME OF REPORT SUBMISSION. THE MANUFACTURER WILL SUBMIT A SUPPLEMENTAL REPORT IF NEW FACTS ARISE WHICH MATERIALLY ALTER INFORMATION SUBMITTED IN A PREVIOUS MDR REPORT. ADDITIONAL INFORMATION WILL BE SUBMITTED WITHIN 30 DAYS OF RECEIPT. THE ARTICLE CANNOT BE ATTACHED TO DUE ELECTRONIC FILE SIZE
THIS COMPLAINT IS FROM A LITERATURE SOURCE AND THE FOLLOWING CITATION WAS REVIEWED: FORBRIG R, LOCKAU H, FLOTTMANN F, BOECKH-BEHRENS T, KABBASCH C, PATZIG M, MPOTSARIS A, FIEHLER J, LIEBIG T, THOMALLA G, ONUR OA, WUNDERLICH S, KREISER K, HERZBERG M, WOLLENWEBER FA, PROTHMANN S, DORN F. INTRACRANIAL RESCUE STENT ANGIOPLASTY AFTER STENT-RETRIEVER THROMBECTOMY : MULTICENTER EXPERIENCE. CLIN NEURORADIOL. 2019 SEP;29(3):445-457. DOI: 10.1007/S00062-018-0690-4. EPUB 2018 MAY 14. PMID: 29761219. OBJECTIVE AND METHODS: TO PRESENT RETROSPECTIVE MULTICENTER STUDY AND REPORT ON EXPERIENCE WITH RSA IN PATIENTS WITH ACUTE INTRACRANIAL ANTERIOR AND POSTERIOR CIRCULATION LAO AND IMMEDIATE RE-OCCLUSION AFTER INITIALLY SUCCESSFUL SRT. IN A RETROSPECTIVE ANALYSIS, ALL PATIENTS WITH ACUTE INTRACRANIAL LAO OF THE ANTERIOR AND POSTERIOR CIRCULATION, WHO UNDERWENT RSA BETWEEN (B)(6) 2012 AND (B)(6) 2017, WERE IDENTIFIED FROM THE STROKE DATABASES OF FOUR TERTIARY STROKE CENTERS. IN ALL CENTERS, A TOTAL OF (B)(4) INTRACRANIAL THROMBECTOMIES WERE CONDUCTED IN THIS TIME PERIOD. AFTER FILTERING FOR INCLUSION/EXCLUSION DATA REQUIREMENTS, A TOTAL OF 34 PATIENTS WERE INCLUDED IN THE ANALYSIS. MEAN AGE WAS 67 YEARS AND 11 PATIENTS (32%) WERE FEMALE. TABLE 1 SUMMARIZES THE PATIENTS¿ BASELINE CHARACTERISTICS, INTERVENTIONAL DATA, AND CLINICAL OUTCOME. WITHIN THE TABLE, FIVE PATIENTS WERE IDENTIFIED WITH CNV PRODUCTS AND ADVERSE EVENTS: PATIENT (B)(6). THIS COMPLAINT CAPTURES THESE PATIENTS. LOT, MODEL AND CATALOG NUMBER ARE NOT AVAILABLE, BUT THE SUSPECTED CERENOVUS DEVICE POSSIBLY ASSOCIATED WITH REPORTED ADVERSE EVENTS: ENTERPRISE STENT OTHER CERENOVUS DEVICES THAT WERE ALSO USED IN THIS STUDY: N/A. NON-CERENOVUS DEVICES THAT WERE ALSO USED IN THIS STUDY: N/A TO THESE PATIENTS. ADVERSE EVENT(S) AND PROVIDED INTERVENTIONS: (B)(6) FEMALE WITH M1 OCCLUSION SITE, RECEIVED AN ENTERPRISE STENT AND EXPERIENCED EARLY POST-INTERVENTIONAL OCCLUSION AT 24 HOURS AT THE TREATED SITE, NO INTRACRANIAL HEMORRHAGE IN THE ACUTE POST-INTERVENTIONAL PHASE. (B)(6) FEMALE WITH DISTAL ICA OCCLUSION SITE, RECEIVED AN ENTERPRISE STENT AND EXPERIENCED EARLY POST-INTERVENTIONAL OCCLUSION AT 24 HOURS AT THE TREATED SITE, EXPERIENCED INTRACRANIAL HEMORRHAGE IN THE ACUTE POST-INTERVENTIONAL PHASE. (B)(6) FEMALE WITH M1 OCCLUSION SITE, RECEIVED AN ENTERPRISE STENT AND EXPERIENCED EARLY POST-INTERVENTIONAL OCCLUSION AT 24 HOURS AT THE TREATED SITE, NO INTRACRANIAL HEMORRHAGE IN THE ACUTE POST-INTERVENTIONAL PHASE. (B)(6) MALE WITH BA OCCLUSION SITE, RECEIVED AN ENTERPRISE STENT AND EXPERIENCED EARLY POST-INTERVENTIONAL OCCLUSION AT 24 HOURS AT THE TREATED SITE, NO INTRACRANIAL HEMORRHAGE IN THE ACUTE POST-INTERVENTIONAL PHASE. (B)(6) YEARS OLD MALE WITH PETROUS ICA OCCLUSION SITE, RECEIVED AN ENTERPRISE STENT AND EXPERIENCED RESTENOSIS GREATER THAN 50% AFTER 3 MONTHS, NO INTRACRANIAL HEMORRHAGE IN THE ACUTE POST-INTERVENTIONAL PHASE.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1931970 | STENT - VASCULAR RECONSTRUCTION | INTRACRANIAL NEUROVASCULAR STENT | NJE | MEDOS INTERNATIONAL SARL |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Unknown | Life Threatening |