MAZOR X SYSTEM
Report
- Report Number
- 3005075696-2021-00133
- Event Type
- Malfunction
- Date Received
- December 14, 2021
- Date of Event
- July 1, 2021
- Report Date
- December 14, 2021
- Manufacturer
- MAZOR ROBOTICS LTD
- Product Code
- OLO
- PMA / PMN Number
- K182077
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- CA, US
- Reporter Occupation
- PHYSICIAN
- Health Professional
- Yes
Narratives
PLEASE NOTE THAT THIS DATE IS BASED OFF THE DATE OF PUBLICATION OF THE ARTICLE AS THE ACTUAL EVENT DATE WAS NOT PROVIDED. THE REPORTED EVENT WAS FROM THE FOLLOWING LITERATURE ARTICLE: DIAZ-AGUILAR L, SHAH V, HIMSTEAD A, BROWN N, ABRAHAM M, PHAM M. SIMULTANEOUS ROBOTIC SINGLE-POSITION SURGERY (SR-SPS) WITH OBLIQUE L UMBAR INTERBODY FUSION: A CASE SERIES. WORLD NEUROSURGERY. 2021. 151: E1036-E1043. HTTPS://DOI.ORG/10.1016/J.WNEU.2021.05.043. IF INFORMATION IS PROVIDED IN THE FUTURE, A SUPPLEMENTAL REPORT WILL BE ISSUED.
ABSTRACT: THE OBLIQUE LATERAL INTERBODY FUSION (OLIF) PROCEDURE IS AN IMPORTANT COMPONENT OF THE SURGEON¿S ARMAMENTARIUM FOR THE TREATMENT OF DEGENERATIVE SPINAL CONDITIONS. OLIF WITH POSTERIOR SPINAL FIXATION FREQUENTLY IS PERFORMED AND REQUIRES ADDITIONAL TIME BECAUSE THE PATIENT IS FLIPPED TO A PRONE POSITION AND RE-DRAPED. WE REPORT A SERIES OF CASES IN WHICH ROBOTIC ASSISTANCE WAS USED FOR A 2-SURGEON WORKFLOW IN WHICH OLIF AND SINGLE LATERAL POSITION POSTERIOR SPINAL FIXATION WERE PERFORMED AT THE SAME TIME, TERMED SIMULTANEOUS ROBOTIC SINGLE POSITION SURGERY (SR-SPS). DATA WERE COLLECTED RETROSPECTIVELY FROM MEDICAL RECORDS OF 13 CONSECUTIVE PATIENTS WHO UNDERWENT SR-SPS BY A SINGLE SURGEON AT AN ACADEMIC CENTER BETWEEN JUNE AND DECEMBER 2020. INSTRUMENTATION ACCURACY, TOTAL OPERATING ROOM TIME, ESTIMATED BLOOD LOSS, LENGTH OF STAY, AND COMPLICATIONS WERE ASSESSED. A TOTAL OF 13 PATIENTS WHOSE MEAN AGE WAS 64.1 YEARS (RANGE 46 - 84 YEARS) UNDERWENT SR-SPS OVER A 6-MONTH PERIOD. AVERAGE FOLLOW-UP WAS 10.3 MONTHS. ALL PATIENTS WERE TREATED FOR DEGENERATIVE SPINE DISEASE. THE AVERAGE OPERATIVE DURATION WAS 111.2 +- 25.2 MINUTES. A TOTAL OF 60 PEDICLE SCREWS WERE PLACED BILATERALLY IN THE LATERAL POSITION WITH AN ACCURACY RATE OF 95.0%. COMPLICATIONS INCLUDED 1 POSTOPERATIVE SEROMA, AND 1 PATIENT REQUIRED REOPERATION 3 MONTHS POSTOPERATIVELY DUE TO A FALL. WE REPORT THE FIRST CASE SERIES DESCRIBING SR-SPS. OUR STUDY SHOWS THAT THIS METHOD CAN REDUCE OPERATIVE TIME WHILE ENSURING ACCURATE. REPORTED EVENTS 1. DURING USE OF THE GUIDANCE SYSTEM FOR SPINAL SURGERY TO PLACE SCREWS, THERE WERE THREE LATERAL BREACHES AND NO MEDIAL OR INFERIOR BREACHES. NO PATIENT HARM WAS REPORTED.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1904337 | MAZOR X SYSTEM | ORTHOPEDIC STEREOTAXIC INSTRUMENT | OLO | MAZOR ROBOTICS LTD | TPL0059 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Unknown |