FDA Adverse Event Injury Summary report: N

UNK HIP ACETABULAR CUP PINNACLE

MDR report key: 12689769 · Received October 25, 2021

Report

Report Number
1818910-2021-23450
Event Type
Injury
Date Received
October 25, 2021
Date of Event
August 10, 2021
Report Date
October 11, 2021
Manufacturer
DEPUY ORTHOPAEDICS INC US
Product Code
JDI
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
GM
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

PRODUCT COMPLAINT # (B)(4). IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE.

Additional Manufacturer Narrative · 0

PRODUCT COMPLAINT # (B)(4). INVESTIGATION SUMMARY : NO DEVICE ASSOCIATED WITH THIS REPORT WAS RECEIVED FOR EXAMINATION. THIS COMPLAINT WAS OPENED TO DOCUMENT COMPLAINTS DERIVED THROUGH A JOURNAL ARTICLE REVIEW. FOLLOW-UPS WERE DONE TO TRY AND OBTAIN ADDITIONAL INFORMATION FROM THE AUTHOR OF THE JOURNAL ARTICLE. NO FURTHER INFORMATION WAS RECEIVED. DEVICE HISTORY LOT : A MANUFACTURING RECORD EVALUATION (MRE), WAS NOT POSSIBLE BECAUSE THE REQUIRED LOT CODE WAS NOT PROVIDED.

Description of Event or Problem · 0

THIS COMPLAINT IS FROM A LITERATURE SOURCE. THE FOLLOWING LITERATURE CITE HAS BEEN REVIEWED: MIGLIORINI F, DRIESSEN A, ESCHWEILER J, TINGART M, MAFFULLI N. NO BENEFITS OF MINIMALLY INVASIVE TOTAL HIP ARTHROPLASTY VIA WATSON-JONES APPROACH: A RETROSPECTIVE COHORT STUDY. SURGEON. 2021 AUG 10:S1479-666X(21)00129-3. DOI: 10.1016/J.SURGE.2021.07.004. EPUB AHEAD OF PRINT. PMID: 34389254. OBJECTIVE AND METHODS: HE PRESENT STUDY AIMED TO INVESTIGATE WHETHER A MIS APPROACH HAS A POSITIVE IMPACT ON THE OUTCOME OF THA VIA THE WATSON-JONES ANTEROLATERAL APPROACH. CLINICAL SCORES AND RADIOLOGICAL FINDINGS OF MINIMALLY AND STANDARD INVASIVE EXPOSURES WERE EVALUATED AND COMPARED. DATA FROM 140 PATIENTS (70 PATIENTS FOR EACH GROUP) WHO WERE OPERATED ON BETWEEN 2017 AND 2018 IN TWO DIFFERENT ORTHOPAEDIC INSTITUTIONS WERE ANALYZED AT TWO-YEARS FOLLOW-UP. THE PATIENT IN THE MIS GROUP RECEIVED A COMPETITOR THA. THE PATIENTS IN THE SIS GROUP RECEIVED A PINNACLE POROCOAT CUP, CORAIL HA COATED STEM, AN UNKNOWN POLYETHYLENE LINER, AND EITHER A METAL OR CERAMIC FEMORAL HEAD. THE SIS GROUP CONSISTED OF 59 WOMEN AND 11 MEN WITH A MEAN AGE OF 66.1. THE AUTHORS CONCLUDED THAT TOTAL HIP ARTHROPLASTY THROUGH THE WATSON-JONES ANTEROLATERAL APPROACH ACHIEVES EXCELLENT RESULTS AT TWO YEARS FOLLOW-UP. SURGERY PERFORMED VIA MIS PROVIDES NO SUPERIOR OUTCOME COMPARED TO THE SIS IN TERMS OF RADIOGRAPHIC FINDINGS AND PROMS. THIS COMPLAINT WILL CAPTURE THE RESULTS ASSOCIATED WITH THE SIS GROUP, AS THIS IS THE ONLY GROUP WITH DEPUY DEVICES. LOT, MODEL AND CATALOG NUMBER ARE NOT AVAILABLE, BUT THE SUSPECTED DEPUY DEVICE POSSIBLY ASSOCIATED WITH REPORTED ADVERSE EVENTS: PINNACLE CUP UNKNOWN HEAD UNKNOWN LINER CORAIL STEM ADVERSE EVENT(S) AND PROVIDED INTERVENTIONS ASSOCIATED WITH DEPUY DEVICES: 1 PATIENT RECEIVED A REVISION TO TREAT ASEPTIC LOOSENING OF AN UNKNOWN COMPONENT. AN UNKNOWN NUMBER OF PATIENTS REPORTED PAIN, LEG LENGTH DISCREPANCY, AND STIFFNESS ON A PATIENT SURVEY. NO TREATMENT WAS PROVIDED.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1589751 UNK HIP ACETABULAR CUP PINNACLE HIP ACETABULAR CUP JDI DEPUY ORTHOPAEDICS INC US

Patients

Seq Age Sex Outcome Treatment
1 Unknown Required Intervention