FDA Adverse Event Injury Summary report: N

BELOTERO BALANCE

MDR report key: 12689222 · Received October 25, 2021

Report

Report Number
3013840437-2021-00221
Event Type
Injury
Date Received
October 25, 2021
Report Date
November 26, 2021
Manufacturer
ANTEIS S.A
Product Code
LMH
PMA / PMN Number
P090016
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
TW
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

THIS CASE WAS ASSESSED AS REPORTABLE TO THE FDA AS THE EVENT, VASCULAR OCCLUSION (VASCULAR OCCLUSION), WAS DEEMED TO MEET SERIOUS INJURY CRITERIA OF RESULTED IN HOSPITALIZATION. THE DEVICE HISTORY RECORD COULD NOT BE REVIEWED AS THE LOT NUMBER WAS NOT REPORTED LITERATURE CITATION: LEE, A.-L.; CHEN, Y.-F.; YAO, W.-T.; LIU, Y.-C.; YU, C.-M.; YU, C.-M.; TU, C.-P.; HUANG, W.-C.; TUNG, K.-Y.; TSAI, M.-F. LASER DOPPLER IMAGING FOR TREATING VASCULAR COMPLICATIONS FROM PROCEDURES INVOLVING DERMAL FILLERS: CASE SERIES AND LITERATURE REVIEW. DIAGNOSTICS 2021, 11, 1640. HTTPS:// DOI.ORG/10.3390/DIAGNOSTICS11091640

Description of Event or Problem · 0

THIS MDR IS LINKED TO MDR 3013840437-2021-00222 REFERRING TO THE SAME PATIENT. FOLLOW-UP INFORMATION WAS RECEIVED ON 18-NOV-2021: IT WAS CONFIRMED THAT NO COMPANY HYALURONIC ACID WAS INVOLVED. THE OUTCOME OF THE EVENTS WAS LEFT UNCHANGED.

Description of Event or Problem · 0

THIS MDR IS RELATED TO MDR 3013840437-2021-00222 REFERRING TO THE SAME PATIENT. THIS CASE WAS LINKED TO (B)(4), REFERRING TO THE SAME LITERATURE ARTICLE. THIS IS A LITERATURE REPORT FROM A RETROSPECTIVE STUDY AIMED TO ASSESS THE USE OF LASER DOPPLER IMAGING IN THE EVALUATION AND TREATMENT OF VASCULAR COMPLICATIONS CAUSED BY DERMAL FILLER INJECTIONS. THIS LITERATURE REPORT FROM TAIWAN CONCERNS A (B)(6) FEMALE PATIENT. SHE WAS INJECTED WITH A TOTAL OF 2 ML OF HYALURONIC ACID, INTO THE NASOLABIAL FOLDS (BILATERAL, OFF LABEL USE OF DEVICE). SHE WAS INJECTED WITH 1 ML PER SIDE. A 25-G CANNULA WAS USED FOR THE INJECTION. THE PATIENTS PAST MEDICAL HISTORY INCLUDED AN OPEN RHINOPLASTY AND SEPTAL RECONSTRUCTION 1 YEAR PRIOR. AFTER THE HYALURONIC ACID INJECTION, THE PATIENT EXPERIENCED A SKIN ISCHEMIA. THE TREATING PHYSICIAN IMMEDIATELY PERFORMED A NEEDLING AND HYALURONIDASE INJECTION AT THE SITE AND TRANSFERRED THE PATIENT TO THE EMERGENCY DEPARTMENT. SHE WAS ADMITTED 6 HOURS AFTER THE INJECTION. THE PATIENT HAD AN EARLY-STAGE VASCULAR COMPLICATIONS. THE PATIENT UNDERWENT A CLINICAL EXAMINATION, FACIAL PHOTOGRAPHY AND LASER DOPPLER IMAGING. ON THE DAY OF ADMISSION, CLINICAL/PHOTOGRAPHIC FINDINGS SHOWED CYANOTIC CHANGE OF THE NASAL TIP, RIGHT NASAL ALA, RIGHT NASOLABIAL FOLD, RIGHT MOUTH ANGLE/RIGHT UPPER AND LOWER LIPS, RIGHT GLABELLAR REGION. AS REPORTED, THE PATIENTS PARTIAL FACIAL SKIN CYANOSIS, WAS PROBABLY CAUSED BY THE INADVERTENT INTRAVASCULAR INJECTION OF DERMAL FILLER. IN ADDITION TO THE CYANOTIC AREAS SEEN ON THE PHOTOGRAPHS, MOST OF THE AREAS INVOLVED WERE ACCOMPANIED BY PAIN AND/OR NUMBNESS. BECAUSE THE PATIENT WAS ADMITTED LATE AT NIGHT, ANCILLARY THERAPY WITH PROSTAGLANDIN E1, STEROIDS, AND ANTIBIOTICS WAS ADMINISTERED. THE FOLLOWING DAY, LASER DOPPLER IMAGING WAS PERFORMED. THE INITIAL LASER DOPPLER IMAGING WAS PERFORMED USING A MOOR LASER DOPPLER IMAGING DEVICE. THE DEVICE WAS PLACED AT A DISTANCE OF 57 CM FROM THE PATIENT, AND IMAGES WERE OBTAINED AT A TEMPORAL RESOLUTION OF 4 MS/PIXEL. ONE DAY AFTER ADMISSION, LASER DOPPLER IMAGING SHOWED RIGHT NASAL ALA, RIGHT NASOLABIAL FOLD, RIGHT LOWER LIP PARTIAL PERFUSION DEFECT. NEEDLING AND A HYALURONIDASE INJECTION WERE PERFORMED. THE NEEDLE PUNCTURES AND HYALURONIDASE DOSES WERE PERFORMED BASED ON THE LASER DOPPLER IMAGING FINDINGS, IN WHICH 25-G NEEDLES WERE USED TO PUNCTURE BLOOD VESSELS IN THE AREA OF VASCULAR OCCLUSION (FURTHER DESCRIBED AS ARTERIAL OCCLUSION). THE AIM WAS TO ENSURE THE EXTRAVASATION OF DERMAL FILLER WITHIN BLOOD VESSELS BY PUNCTURING THOSE THAT WERE AFFECTED. THE AREA WITH THE MOST REDUCED PERFUSION ON THE LASER DOPPLER IMAGING IMAGE WAS PUNCTURED SEVERAL TIMES OR UNTIL BLEEDING WAS NOTICED. IF THE PUNCTURE HOLE BEGAN TO RE-BLEED, INDICATING A THERAPEUTIC EFFECT, PUNCTURING WAS STOPPED IN THAT AREA AND CONTINUED IN OTHER SUSPICIOUS AREAS. IF NO SUBSTANTIAL BLEEDING OCCURRED, OR IF LITTLE INJECTED MATERIAL WAS SEEN IN THE PINHOLE OF THE HYALURONIDASE NEEDLE, THE AREA WAS PUNCTURED MORE TIMES AND HYALURONIDASE INJECTION WAS CONTINUED. AS REPORTED, THERE WAS INITIAL WORSENING AND GRADUAL IMPROVEMENT OF CUTANEOUS SYMPTOMS. OVER THE NEXT 3 DAYS, THE CYANOSIS IN HER RIGHT NASOLABIAL FOLD AND RIGHT UPPER AND LOWER LIP WAS RESOLVED. HOWEVER, THE RIGHT ALA CYANOSIS GRADUALLY BECAME GANGRENOUS. ALTHOUGH PROSTAGLANDIN E1 WAS CONTINUED, HER SYMPTOMS DID NOT IMPROVE. SUBSEQUENT FOLLOW-UP IMAGING WAS PERFORMED EVERY 1 - 3 DAYS. THE PATIENT WAS PHOTOGRAPHED BEFORE EACH IMAGING ROUND. THREE DAYS AFTER ADMISSION, CLINICAL/PHOTOGRAPHIC FINDINGS SHOWED CYANOTIC CHANGE OF THE RIGHT NASAL ALA, RIGHT MOUTH ANGLE/RIGHT UPPER AND LOWER LIPS. LASER DOPPLER IMAGING SHOWED RIGHT NASAL ALAR PERFUSION DEFECT. AS REPORTED, SEVERAL LASER DOPPLER IMAGING PROCEDURES WERE PERFORMED IN SUCCESSION, AND PERFUSION DEFECT WAS NOTED ONLY IN THE LEFT RIGHT ALA. AS REPORTED, IF THE PREVIOUSLY PUNCTURED AREA CONTINUED TO EXHIBIT REDUCED FLOW, NEEDLING WAS PERFORMED AGAIN, WITH OR WITHOUT HYALURONIDASE. FOLLOW-UP LASER DOPPLER IMAGING WAS CONTINUED UNTIL PERFUSION WAS COMPLETELY RESTORED OR UNTIL THE SKIN WAS CONFIRMED TO BE NECROTIC. PHOTOGRAPHIC EVALUATIONS WERE CONTINUED UNTIL THE FACIAL SKIN COMPLETELY RETURNED TO NORMAL. AS REPORTED, SUBSEQUENT FOLLOW-UP IMAGING WAS NOT PERFORMED IF LASER DOPPLER IMAGING SHOWED REVASCULARIZATION OF THE AREAS WITH REDUCED FLOW OR IF THERE WAS CLINICAL CONFIRMATION OF IRREVERSIBLE NECROSIS OF THE SKIN. ON DAY 12 OF ADMISSION, ALTHOUGH THE ORIGINALLY AFFECTED AREA DID NOT RETURN TO ITS NORMAL STATE OF APPEARANCE, BLOOD CIRCULATION OF THE OTHER PARTS, EXCEPT FOR THE RIGHT ALA, WAS RESTORED. APPROXIMATELY 2 WEEKS AFTER ADMISSION, CLINICAL/PHOTOGRAPHIC FINDINGS SHOWED RIGHT ALAR ESCHAR. LASER DOPPLER IMAGING SHOWED NO PERFUSION OVER RIGHT NASAL ALA. SHE WAS OBSERVED FOR 15 DAYS AFTER ADMISSION, BEFORE THE RIGHT ALA SKIN WAS JUDGED TO HAVE UNDERGONE FULL-THICKNESS NECROSIS. ONLY THE RIGHT ALA EXHIBITED THICK SKIN NECROSIS. AFTER THE OTHER AREAS WERE TREATED, THE PATIENT WAS DISCHARGED WITH A 1-WEEK PRESCRIPTION OF CILOSTAZOL AND ANTIBIOTICS. THE REST OF THE AREAS RECOVERED WELL AFTER DISCHARGE. HOWEVER, THE RIGHT ALA SKIN HEALED AFTER APPROXIMATELY 2 MONTHS, PRODUCING A MORE PRONOUNCED SCAR CONTRACTURE. SHE WAS FOLLOWED UP FOR 53 DAYS, OVERALL. THERE WERE NO COMPLICATIONS FROM THE PROCEDURE. AS REPORTED, A SATISFACTORY OUTCOME WAS ACHIEVED. ACCORDING TO THE AUTHOR, GIVEN THE NATURE OF THE PROBLEM BEING TREATED AND SINCE THE PATIENT WAS DISCHARGED WITH FAVORABLE OUTCOMES, IT WAS STRONGLY SUGGESTED THAT ALL PERFUSION DEFECTS WERE SUCCESSFULLY RESOLVED. DUE TO THE PROVIDED INFORMATION, THE OUTCOME OF THE EVENTS WAS CONSIDERED AS RESOLVED WITH SEQUELAE. IN THE OPINION OF THE AUTHORS, THE AREAS AT HIGH RISK OF VASCULAR OCCLUSION AND NECROSIS WERE THE GLABELLA, NASAL ALA, CHEEKS, PERIORAL REGION, AND TEMPLES. OF THESE, THE GLABELLA CARRIED THE HIGHEST RISK BECAUSE THE VESSELS WERE THE THINNEST, AND THE AREA HAD THE LEAST COLLATERAL CIRCULATION. INTRAARTERIAL INJECTION OF DERMAL FILLER HAD THE POSSIBILITY TO OCCUR WHEN USING EITHER NEEDLES OR CANNULAS. WITH THE LATTER, THE INADVERTENT INTRAVASCULAR INJECTION WAS OFTEN BECAUSE IT WAS IMPOSSIBLE FOR THE PRACTITIONER TO PERCEIVE THE DIFFERENCE BETWEEN PENETRATING A FIBROUS SEPTUM AND AN ARTERY WHEN PERFORMING A BLIND PUNCTURE. THE RISKS ASSOCIATED WITH INTRAVASCULAR INJECTION OF DERMAL FILLERS WAS REDUCED BY ASPIRATING FROM THE NEEDLE OR CANNULA PRIOR TO THE INJECTION TO VERIFY THAT THERE WAS NO BACKFLOW OF BLOOD; USING SMALL VOLUMES AND ADMINISTERING SEVERAL SMALL INJECTIONS IN HIGH-RISK AREAS SUCH AS THE GLABELLA; INJECTING IN A MORE SUPERFICIAL PLANE; TREATING ONLY ONE SIDE AT A TIME; PINCHING AND/OR TENTING THE SKIN TO CREATE INCREASED SPACE SUPERFICIAL TO THE BRANCHES OF THE MAIN ARTERIES, AND COMPRESSING THE ORIGIN OF THE SUPRATROCHLEAR VESSELS WITH A NONDOMINANT FINGER. IN SPECIFICALLY SENSITIVE REGIONS SUCH AS THE GLABELLA, IT WAS RECOMMENDED THAT VERY LOW VOLUMES OF FILLER WERE USED. THE RESULTS SHOWED THAT LASER DOPPLER IMAGING AND NEEDLING ACCURATELY LOCATED THE ISCHEMIC AREAS AFFECTED BY DERMAL FILLER EMBOLI AND THAT THEY IMPROVED TREATMENT PRECISION FOR THE PATIENT. THE PRINCIPLE BEHIND THE THERAPY WAS TO PUNCTURE THE ARTERIES EMBOLIZED WITH DERMAL FILLER SO AS TO RELEASE THE MATERIAL INTO THE EXTRAVASCULAR SPACE, AND THEREBY RELIEVE OBSTRUCTIONS. THE PROCEDURE WAS MORE PRECISE THAN VISUAL INSPECTION OR PHOTOGRAPHIC EVIDENCE. PROSTAGLANDIN E1 WAS USED SINCE IT PRODUCED EFFECTS OF BOTH VASODILATION AND PLATELET AGGREGATION INHIBITION. THE AUTHORS BELIEVE THAT PROSTAGLANDIN E1 IMPROVED THE ISCHEMIC CHANGES CAUSED BY INTRAVASCULAR INJECTION AND HELPED MAINTAIN SKIN PERFUSION DURING TREATMENT. LASER DOPPLER IMAGING RELIABLY IDENTIFIED SKIN PERFUSION DEFECTS WITHOUT INTERFERENCE FROM OTHER FACTORS, AND EFFECTIVELY TRACKED TREATMENT OUTCOMES.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1589478 BELOTERO BALANCE IMPLANT, DERMAL, FOR AESTHETIC USE LMH ANTEIS S.A

Patients

Seq Age Sex Outcome Treatment
1 31 YR Female Hospitalization CONCOMITANT DRUG NOT AVAILABLE.