FDA Adverse Event Injury Summary report: N

REVERSE SHOULDER SYSTEM 04.01.0119 HUMERAL REVERSE HC LINER 36/+0MM

MDR report key: 12681474 · Received October 22, 2021

Report

Report Number
3005180920-2021-00818
Event Type
Injury
Date Received
October 22, 2021
Date of Event
September 22, 2021
Report Date
October 22, 2021
Manufacturer
MEDACTA INTERNATIONAL SA
Product Code
PHX
UDI-DI
07630040706261
PMA / PMN Number
K170452
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
US
Reporter Occupation
003

Narratives

Additional Manufacturer Narrative · 1

DEVICES INVOLVED IN THE FIRST REVISION ((B)(6) 2021): BATCH REVIEW PERFORMED ON 28 SEPTEMBER 2021: LOT 2101810: (B)(4) ITEMS MANUFACTURED AND RELEASED ON 06-APR-2021. EXPIRATION DATE: 2026-MAR-21. NO ANOMALIES FOUND RELATED TO THE PROBLEM. TO DATE, (B)(4) ITEMS OF THE SAME LOT HAVE BEEN SOLD WITHOUT ANY SIMILAR REPORTED EVENT. OTHER DEVICE INVOLVED: BATCH REVIEW PERFORMED ON 28 SEPTEMBER 2021: REVERSE SHOULDER SYSTEM 04.01.0110 HUMERAL REVERSE METAPHYSIS +0MM/0° (K170452) LOT 2003852: (B)(4) ITEMS MANUFACTURED AND RELEASED ON 01-APR-2021. EXPIRATION DATE: 2026-MAR-19. NO ANOMALIES FOUND RELATED TO THE PROBLEM. TO DATE, (B)(4) ITEMS OF THE SAME LOT HAVE BEEN SOLD WITHOUT ANY SIMILAR REPORTED EVENT. DEVICES INVOLVED IN THE SECOND REVISION SURGERY ((B)(6) 2021): BATCH REVIEW PERFORMED ON 28 SEPTEMBER 2021: REVERSE SHOULDER SYSTEM 04.01.0119 HUMERAL REVERSE HC LINER Ø36/+0MM (K170452) LOT 2101810: (B)(4) ITEMS MANUFACTURED AND RELEASED ON 06-APR-2021. EXPIRATION DATE: 2026-MAR-21. NO ANOMALIES FOUND RELATED TO THE PROBLEM. TO DATE, (B)(4) ITEMS OF THE SAME LOT HAVE BEEN SOLD WITHOUT ANY SIMILAR REPORTED EVENT. BATCH REVIEW PERFORMED ON 15 OCTOBER 2021: REVERSE SHOULDER SYSTEM 04.01.0112 HUMERAL REVERSE METAPHYSIS +0MM/+20°L LOT. (K170452) LOT 163789: (B)(4) ITEMS MANUFACTURED AND RELEASED ON 20-DEC-2016. EXPIRATION DATE: 2021-NOV-08. NO ANOMALIES FOUND RELATED TO THE PROBLEM. TO DATE, (B)(4) ITEMS OF THE SAME LOT HAVE BEEN SOLD WITHOUT ANY SIMILAR REPORTED EVENT SINCE 2017. BATCH REVIEW PERFORMED ON 19 OCTOBER 2021: REVERSE SHOULDER SYSTEM 04.01.0186 SHORT HUMERAL DIAPHYSIS - CEMENTLESS - 13 (K180089) LOT 2003729: (B)(4) ITEMS MANUFACTURED AND RELEASED ON 25-JUNE-2020. EXPIRATION DATE: 2025-JUNE-16. NO ANOMALIES FOUND RELATED TO THE PROBLEM. TO DATE, (B)(4) ITEMS OF THE SAME LOT HAVE BEEN SOLD WITHOUT ANY SIMILAR REPORTED EVENT.

Description of Event or Problem · 1

THE PATIENT CAME IN REPORTING INSTABILITY AND THE CAUSE OF THE INSTABILITY IS UNKNOWN. ON (B)(6) 2021, ABOUT 2 WEEKS AFTER THE PRIMARY SURGERY, THE SURGEON REVISED LINER AND METAPHYSIS. THE SURGERY WAS COMPLETED SUCCESSFULLY. ON (B)(6) 2021, THE PATIENT CAME IN REPORTING SHOULDER INSTABILITY AND THE CAUSE OF THE SHOULDER INSTABILITY IS UNKNOWN. THE SURGEON REVISED METAPHYSIS, LINER, AND DIAPHYSIS WITH COMPETITOR COMPONENTS. THE SURGERY WAS COMPLETED SUCCESSFULLY.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1581138 REVERSE SHOULDER SYSTEM 04.01.0119 HUMERAL REVERSE HC LINER 36/+0MM HUMERAL REVERSE LINER PHX MEDACTA INTERNATIONAL SA 04.01.0119 2101810 07630040706261

Patients

Seq Age Sex Outcome Treatment
1 Other