FDA Adverse Event Injury Summary report: N

SURGICEL ABSORBABLE HEMOSTAT UNKNOWN

MDR report key: 12615399 · Received October 12, 2021

Report

Report Number
2210968-2021-09539
Event Type
Injury
Date Received
October 12, 2021
Date of Event
June 30, 2015
Report Date
September 24, 2021
Manufacturer
ETHICON INC.
Product Code
LMG
PMA / PMN Number
N12159
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
IT
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 1

(B)(4). THIS REPORT IS RELATED TO A JOURNAL ARTICLE, THEREFORE NO PRODUCT WILL BE RETURNED FOR ANALYSIS AND THE MANUFACTURING RECORD EVALUATION CANNOT BE REVIEWED AS THE LOT NUMBER HAS NOT BEEN PROVIDED. CITATION: J ROBOTIC SURG (2015); 9:215¿222. DOI 10.1007/S11701-015-0519-Y. EVENT RELATED TO MW# 2210968-2021-09538.

Description of Event or Problem · 1

IT WAS REPORTED VIA A JOURNAL ARTICLE: TITLE: ROBOTIC SURGERY AND HEMOSTATIC AGENTS IN PARTIAL NEPHRECTOMY: A HIGH RATE OF SUCCESS WITHOUT VASCULAR CLAMPING AUTHORS: LUCA MORELLI, JOHN MORELLI, MATTEO PALMERI, CRISTIANO D¿ISIDORO, EMANUELE FEDERICO KAUFFMANN, DARIO TARTAGLIA, GIOVANNI CAPRILI, ROBERTA PISANO, SIMONE GUADAGNI, GREGORIO DI FRANCO, GIULIO DI CANDIO, FRANCO MOSCA CITATION: J ROBOTIC SURG (2015); 9:215¿222. DOI 10.1007/S11701-015-0519-Y. THE AIM OF THIS RETROSPECTIVE STUDY OF A PROSPECTIVELY COLLECTED DATA IS TO DESCRIBE THE AUTHOR'S INITIAL EXPERIENCE OF PERFORMING RPN WITH OR WITHOUT VASCULAR CLAMPING IN COMBINATION WITH SYSTEMATIC USE OF HEMOSTATIC AGENTS. A TOTAL OF 31 PATIENTS [20 MALE AND 11 FEMALE; MEAN AGE OF 65.8 YEARS (RANGE 45-81 YEARS); MEAN BMI OF 25.65 (RANGE 20.2-40.4)] WITH A DIAGNOSIS OF A RENAL MASS ON WHOM A ROBOTIC PARTIAL NEPHRECTOMY WAS PERFORMED FROM FEBRUARY 2009 TO OCTOBER 2014 WERE INCLUDED IN THE STUDY. AFTER REMOVAL OF THE TUMOR, PRIMARY HEMOSTASIS AT THE RESECTION BED WAS MANAGED BY APPLICATION OF A FIBRIN SEALANT (FLOSEAL HEMOSTATIC MATRIX, BAXTER, HEALTHCARE) AND BY COMPRESSION WITH A SURGICAL SPONGE. THE DEFECT WAS FINALLY COVERED WITH A SHEET OF OXIDIZED REGENERATE CELLULOSE (TABOTAMP FIBRILLAR, JOHNSON & JOHNSON; ETHICON, USA). IF THERE WAS FURTHER BLEEDING OR URINE LEAK, PROLENE STICHES WITH OR WITHOUT DACRON PLEDGET WERE USED TO IMPROVE HEMOSTASIS. REPORTED COMPLICATIONS INCLUDE URINARY FISTULA (N=1) WHICH RESOLVED WITH THE PLACEMENT OF A URETERAL STENT, AND THE USE OF PROLENE SUTURES (N=8). IN CONCLUSION, ROBOT-ASSISTED PARTIAL NEPHRECTOMY APPEARS TO BE A SAFE AND EFFECTIVE TECHNIQUE FOR THE SURGICAL MANAGEMENT OF LOCALIZED RENAL MALIGNANCY WHILE PRESERVING ONCOLOGICAL AND CLINICAL GOALS. RECENT ADVANCES OF THE ROBOTIC SYSTEM ITSELF AND THE USE OF HEMOSTATIC AGENTS IMPROVES THE LIKELIHOOD CARRYING OUT A CONSERVATIVE RESECTION WITHOUT ISCHEMIC DAMAGE TO THE KIDNEY IN SELECTED CASES.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1512523 SURGICEL ABSORBABLE HEMOSTAT UNKNOWN AGENT, ABSORBABLE HEMOSTATIC, NON-COLLAGEN BASED LMG ETHICON INC.

Patients

Seq Age Sex Outcome Treatment
1 Required Intervention