FDA Adverse Event Injury Summary report: N

ETHIBOND EXTRA & EXCEL POLYESTER SUTURE UNKNOWN

MDR report key: 12492460 · Received September 17, 2021

Report

Report Number
2210968-2021-08629
Event Type
Injury
Date Received
September 17, 2021
Date of Event
October 6, 2020
Report Date
August 24, 2021
Manufacturer
ETHICON INC.
Product Code
GAT
PMA / PMN Number
K946173
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
CH
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 1

PRODUCT COMPLAINT # (B)(4). COMPONENT CODE: (B)(4) DEVICE NOT RETURNED. THIS REPORT IS RELATED TO A JOURNAL ARTICLE; THEREFORE, NO PRODUCT WILL BE RETURNED FOR ANALYSIS AND THE BATCH HISTORY RECORDS CANNOT BE REVIEWED AS THE LOT NUMBER HAS NOT BEEN PROVIDED. THE SINGLE COMPLAINT WAS REPORTED WITH MULTIPLE EVENTS. THERE ARE NO ADDITIONAL DETAILS, DEMOGRAPHICS REGARDING THE ADDITIONAL EVENTS. ATTEMPTS ARE BEING MADE TO CLARIFY THE FOLLOWING INFORMATION. TO DATE NO RESPONSE HAS BEEN PROVIDED. IF FURTHER DETAILS ARE RECEIVED AT A LATER DATE A SUPPLEMENTAL MEDWATCH WILL BE SENT. DOES THE AUTHOR/SURGEON BELIEVE THAT ETHICON PRODUCTS (ETHIBOND SUTURE AND PDS SUTURE) INVOLVED CAUSED AND/OR CONTRIBUTED TO POST-OP COMPLICATIONS (MENISCAL TEARS (N=1), MEDIAL COLLATERAL LIGAMENT TEARS (N=1), ACL SUBSTANCE RUPTURE(N=1), MENISCAL INJURY) DESCRIBED IN THE ARTICLE? PLEASE SPECIFY. DOES THE AUTHOR/SURGEON BELIEVE THERE WAS ANY DEFICIENCY WITH THE ETHICON PRODUCTS (ETHIBOND SUTURE AND PDS SUTURE) USED FOR CASES DESCRIBED IN THIS STUDY? IF YES, PLEASE PROVIDE A COMPLETE PATIENT DEMOGRAPHICS FOR PATIENTS WITH POST-OP COMPLICATIONS (MENISCAL TEARS (N=1), MEDIAL COLLATERAL LIGAMENT TEARS(N=1), ACL SUBSTANCE RUPTURE(N=1), MENISCAL INJURY)? WERE ALL THESE CASES DISCUSSED IN THIS ARTICLE PREVIOUSLY REPORTED TO ETHICON? IF YES, PLEASE PROVIDE A COMPLAINT REFERENCE NUMBER. CITATION: ORTHOPAEDICS & TRAUMATOLOGY: SURGERY & RESEARCH 107 (2021) 102798; HTTPS://DOI.ORG/10.1016/J.OTSR.2020.102798. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL REPORT, A FOLLOW-UP REPORT WILL BE FILED AS APPROPRIATE. EVENTS WERE SUBMITTED VIA 2210968-2021-08632.

Description of Event or Problem · 1

TITLE: CLINICAL OUTCOMES OF ACUTE DISPLACED POSTERIOR CRUCIATE LIGAMENT TIBIAL AVULSION FRACTURE: A RETROSPECTIVE COMPARATIVE STUDY BETWEEN THE ARTHROSCOPIC SUTURE AND ENDOBUTTON FIXATION TECHNIQUES. THE AIM OF THIS STUDY WAS TO RETROSPECTIVELY COMPARE THE CLINICAL OUTCOMES OF ACUTE DISPLACED POSTERIOR CRUCIATE LIGAMENT AVULSION FRACTURES TREATED WITH ARTHROSCOPIC SUTURE VERSUS ENDO BUTTON FIXATION. WE HYPOTHESIZED THAT THESE TWO DIFFERENT APPROACHES WOULD PRODUCE EQUALLY GOOD CLINICAL RESULTS. METHODS. A TOTAL OF 68 PATIENTS WITH IMAGING EVIDENCE OF POSTERIOR CRU-CIATE LIGAMENT AVULSION FRACTURES FROM JULY 2009 TO OCTOBER 2016 WERE RETROSPECTIVELY REVIEWED. FOR SUTURE FIXATION APPROACH THE TIBIAL BONE BED AND BONE FRAGMENT WERE DEBRIDED WITH A SHAVER THROUGH THE POSTEROMEDIAL AND POSTEROLATERAL PORTALS, AND THE INFERIOR BONE BED WAS CLEARLY EXPOSED. THE PCL TIBIAL DRILL GUIDE(SMITH & NEPHEW) WAS INSERTED FROM THE AM PORTAL INTO THE POSTERIOR COMPARTMENT AT AN ANGLE OF 55, AND THE TIP OF THE GUIDE WAS POSITIONED AT THE MEDIAL AND LATERAL BORDERS OF THE TIBIAL BED. TWO2-MM TUNNELS WERE ESTABLISHED BY THE GUIDE WIRE FROM THE ANTE-RIOR TIBIAL CORTEX TO THE INFEROLATERAL AND INFEROMEDIAL SIDES OF THE BONE BED. A DOUBLE-STRAND NO. 5 ETHIBOND SUTURE WAS INTRODUCED THROUGH THE ANTEROLATERAL PORTAL AND WRAPPED AROUND THE PCL FROM ANTERIOR TO POSTERIOR USING AN EPIDURAL NEEDLE LOADED WITH NO. 1POLYDIOXANONE (PDS) (ETHICON). ALL THE ENDS OF THE SUTURES WERE GRASPED THROUGH THE POSTEROMEDIAL PORTAL. FOR THE ENDO BUTTON FIXATION APPROACH THE DEVICE WAS PREPARED WITH NO.5 ETHIBOND SUTURES (ETHICON). REPORTED COMPLICATIONS INCLUDED MENISCAL TEARS (N=1) TREATED BY PARTIAL MENISCECTOMY IN THE ENDO BUTTON GROUP. MEDIAL COLLATERAL LIGAMENT TEARS(N=1) TREATED BY REPAI RWITH ANCHORS IN THE SUTURE GROUP, ACL SUBSTANCE RUPTURE(N=1) TREATED BY RECONSTRUCTION WITH AN AUTOGRAFTIN THE SUTURE GROUP. MENISCAL INJURY WAS TREATED BY PARTIAL MENISCECTOMY. IN CONCLUSION BOTH THE ARTHROSCOPIC SUTURE AND ENDOBUTTON FIXATION METHODS FOR ACUTE DISPLACED POSTERIOR CRUCIATE LIGAMENT AVULSION FRACTURES RESULTED IN COMPARABLY GOOD CLINICAL OUTCOMES, RADIOLOGIC HEALING ,AND STABLE KNEES AT MID-TERM FOLLOW-UP.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1389251 ETHIBOND EXTRA & EXCEL POLYESTER SUTURE UNKNOWN SUTURE, NONABSORBABLE, SYNTHETIC, POLYETHYLENE GAT ETHICON INC.

Patients

Seq Age Sex Outcome Treatment
1 Required Intervention