FDA Adverse Event Malfunction Summary report: N

MINIMED 770G US SYSTEM BLE CONNECT 3.0 MG/DL

MDR report key: 12472425 · Received September 15, 2021

Report

Report Number
2032227-2021-192561
Event Type
Malfunction
Date Received
September 15, 2021
Date of Event
September 8, 2021
Report Date
February 18, 2022
Manufacturer
MEDTRONIC PUERTO RICO OPERATIONS CO.
Product Code
OZP
UDI-DI
000000763000414344
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
VA, US
Reporter Occupation
OTHER
Health Professional
N

Narratives

Additional Manufacturer Narrative · 0

RETAINER RING=BLACK. ON (B)(6) 2021 CUSTOMER CALLED IN WITH THE FOLLOWING CONCERN: PATIENT WAS AT THE WATER PARK WHEN RECEIVED WITH OPEN BOOK IMAGE. P-CAP LOCKED IN PLACE PROPERLY DURING TESTING. DEVICE WAS SUCCESSFULLY DOWNLOADED USING THUMP SOFTWARE. PROCEED IT WITH THE FOLLOWING TESTING TO ASSURE PROPER FUNCTIONALITY OF THE DEVICE. UNABLE TO PERFORM THE FUNCTIONAL TEST, INCLUDING THE SELF TEST, SLEEP CURRENT MEASUREMENT, ACTIVE CURRENT MEASUREMENT, REWIND TEST, PRIME/SEATING TEST, BASIC OCCLUSION TEST, OCCLUSION TEST, AND DISPLACEMENT TEST DUE TO CRITICAL PUMP ERROR. THE ADAPT TOOL WAS UTILIZED TO SEARCH FOR ALARMS THAT MAY HAVE OCCURRED IN THE PAST OR DURING COMPLAIN CALL THAT MIGHT OF TRIGGER THE REASON COMPLAIN. IN DOWNLOAD HISTORY FILE AND ADAPT TOOL IT RECORDED PUMP ERROR 35 ON (B)(6) 2021 AT 12:54:00 HOUR. DURING DOWNLOAD REVIEW PUMP ERROR 53 ALARM WAS ALSO CONFIRM IN MAIN ERROR LOG. FILE ID:65535 LINE ID: 65535. PER R&D FINDINGS PUMP ERROR 53 WAS TRIGGERED BY A BROKEN FORCE SENSOR. PROCEED IT BY CUTTING DEVICE OPEN AND PERFORM A VISUAL INSPECTION OF CONNECTORS AND ELECTRONIC ASSEMBLIES. PER VISUAL INSPECTION, IT WAS DETERMINED THAT THE INGRESS OF WATER CORRODING ELECTRONIC ASSEMBLIES, MOTOR ASSEMBLY, FORCE SENSOR AND KEYPAD ASSEMBLY CAUSING ELECTRICAL SHORT. FORCE SENSOR ZERO OFFSET WITHIN SPECIFICATIONS. DEVICE ALSO RECEIVED WITH CRACKED CASE. IN CONCLUSION DEVICE CAME IN WITH CRITICAL PUMP ERROR ALARM TRIGGED BY PUMP ERROR 35. PUMP ERROR 53 DUE TO MOISTURE DAMAGE ON ELECTRONIC ASSEMBLIES. MEDTRONIC, INC. (MEDTRONIC) IS SUBMITTING THIS REPORT TO COMPLY WITH 21 C.F.R. PART 803, THE MEDICAL DEVICE REPORTING REGULATION. THIS REPORT IS BASED UPON INFORMATION OBTAINED BY MEDTRONIC, WHICH THE COMPANY MAY NOT HAVE BEEN ABLE TO FULLY INVESTIGATE OR VERIFY PRIOR TO THE DATE THE REPORT WAS REQUIRED BY THE FDA. MEDTRONIC HAS MADE REASONABLE EFFORTS TO OBTAIN MORE COMPLETE INFORMATION IN THE TIME ALLOTTED AND HAS PROVIDED AS MUCH INFORMATION AS IS AVAILABLE TO THE COMPANY AS OF THE SUBMISSION DATE THIS REPORT. THIS REPORT DOES NOT CONSTITUTE AN ADMISSION OR A CONCLUSION BY FDA, MEDTRONIC, OR ITS EMPLOYEES THAT THE DEVICE, MEDTRONIC, OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE EVENT DESCRIBED IN THE REPORT. IN PARTICULAR, THIS REPORT DOES NOT CONSTITUTE AN ADMISSION BY ANYONE THAT THE PRODUCT DESCRIBED IN THIS REPORT HAS ANY "DEFECTS" OR HAS "MALFUNCTIONED". THESE WORDS ARE INCLUDED IN THE FDA 3500A FORM AND ARE FIXED ITEMS FOR SELECTION CREATED BY THE FDA, TO CATEGORIZE THE TYPE OF EVENT SOLELY FOR THE PURPOSE OF REPORTING PURSUANT TO PART 803. MEDTRONIC OBJECTS TO THE USE OF THESE WORDS AND OTHERS LIKE IT BECAUSE OF THE LACK OF DEFINITION AND THE CONNOTATIONS IMPLIED BY THESE TERMS. THIS STATEMENT SHOULD BE INCLUDED WITH ANY INFORMATION OR REPORT DISCLOSED TO THE PUBLIC UNDER THE FREEDOM OF INFORMATION ACT.

Additional Manufacturer Narrative · 1

(B)(4). CURRENTLY IT IS UNKNOWN WHETHER OR NOT THE DEVICE MAY HAVE CAUSED OR CONTRIBUTED TO THE EVENT AS NO PRODUCT HAS BEEN RETURNED. THE DEVICE WILL BE RETURNED FOR ANALYSIS AND FURTHER INFORMATION WILL FOLLOW ONCE THE ANALYSIS HAS BEEN COMPLETED. NO CONCLUSION CAN BE DRAWN AT THIS TIME.

Description of Event or Problem · 1

INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT THE INSULIN PUMP HAD CRITICAL PUMP ERROR. CUSTOMER STATED THAT THE INSULIN PUMP GOT WET. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. THE DEVICE WILL BE RETURNED FOR ANALYSIS.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1376003 MINIMED 770G US SYSTEM BLE CONNECT 3.0 MG/DL ARTIFICIAL PANCREAS DEVICE SYSTEM, SINGLE HORMONAL CONTROL OZP MEDTRONIC PUERTO RICO OPERATIONS CO. MMT-1880 HG50RTUZZ 000000763000414344

Patients

Seq Age Sex Outcome Treatment
1 36 YR Male