FDA Adverse Event Malfunction Summary report: N

UNKNOWN MONO/POLYAXIAL SCREWS

MDR report key: 12455303 · Received September 10, 2021

Report

Report Number
1526439-2021-01950
Event Type
Malfunction
Date Received
September 10, 2021
Report Date
August 13, 2021
Manufacturer
MEDOS INTERNATIONAL SàRL CH
Product Code
NKB
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
CH
Reporter Occupation
PHYSICIAN

Narratives

Additional Manufacturer Narrative · 0

THERE ARE MULTIPLE PATIENTS ALL INFORMATION IS PROVIDED IN THE ARTICLE. THIS REPORT IS FOR AN UNKNOWN MONO/POLYAXIAL SCREW/UNKNOWN LOT. PART AND LOT NUMBER ARE UNKNOWN; UDI NUMBER IS UNKNOWN. IMPLANT DATE IS BETWEEN (B)(6) 2012 TO (B)(6) 2014. COMPLAINANT PART IS NOT EXPECTED TO BE RETURNED FOR MANUFACTURER REVIEW/INVESTIGATION. WITHOUT A LOT NUMBER THE DEVICE HISTORY RECORDS REVIEW COULD NOT BE COMPLETED. PRODUCT WAS NOT RETURNED. BASED ON THE INFORMATION AVAILABLE, IT HAS BEEN DETERMINED THAT NO CORRECTIVE AND/OR PREVENTATIVE ACTION IS PROPOSED. THIS COMPLAINT WILL BE ACCOUNTED FOR AND MONITORED VIA POST MARKET SURVEILLANCE ACTIVITIES. IF ADDITIONAL INFORMATION IS MADE AVAILABLE, THE INVESTIGATION WILL BE UPDATED AS APPLICABLE. DEVICE WAS USED FOR TREATMENT, NOT DIAGNOSIS. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE."

Description of Event or Problem · 0

THIS REPORT IS BEING FILED AFTER THE REVIEW OF THE FOLLOWING JOURNAL ARTICLE: ZENG Z.L., (2015) ANALYSIS OF RISK FACTORS FOR ADJACENT SUPERIOR VERTEBRAL PEDICLE-INDUCED FACET JOINT VIOLATION DURING THE MINIMALLY INVASIVE SURGERY TRANSFORAMINAL LUMBAR INTERBODY FUSION: A RETROSPECTIVE STUDY, EUR J MED RES VOLUME 20, PAGES 1-7 (CHINA) THIS RETROSPECTIVE STUDY AIMS TO REVIEW THE CLINICAL DATA OF 69 PATIENTS WHO UNDERWENT MIS-TLIF, AND ASSESSED RELEVANT RISK FACTORS OF FACET JOINT VIOLATION CAUSED BY ADJACENT SUPERIOR VERTEBRAL PEDICLE SCREW, INCLUDING GENDER, AGE, BMI, THE LOCATION OF ADJACENT UPPER VERTEBRAL, FUSION SEGMENT NUMBERS, SCREW IMPLANT LOCATION AND OTHERS. FROM DECEMBER 2012 TO JUNE 2014, 95 CONSECUTIVE PATIENTS WITH A LUMBAR DEGENERATIVE DISEASE (MALE, 35; FEMALE, 34; AVERAGE AGE: 54.8 ± 4.8 YEARS) UNDERWENT MINIMALLY INVASIVE SURGERY TRANSFORAMINAL LUMBAR INTERBODY FUSION (MIS-TLIF) WERE REVIEWED IN THIS STUDY. OF THE 95 PATIENTS, 73 PATIENTS MET THE INCLUSION CRITERIA. THEN, 4 PATIENTS WERE EXCLUDED. FINALLY, 69 PATIENTS ( WERE INCLUDED IN THE STUDY WITH COMPLETE MEDICAL RECORDS AND FOLLOW-UP DATA. DURING THE SURGERY, FASCIAE. AFTER INSERTING THE DILATORS STEP BY STEP, THE PIPELINE WORKING CHANNEL (JOHNSON & JOHNSON COMPANY, NY, USA, WAS PLACED INTO AND FIXED BY DILATORS, OR DIRECTLY USING THE SPOTLIGHT WORKING CHANNEL (JOHNSON & JOHNSON COMPANY, NY, USA). PLACEMENT OF PERCUTANEOUS PEDICLE SCREWS WAS PERFORMED USING VIPER2 SYSTEM (JOHNSON & JOHNSON COMPANY, NY, USA) AND THE PERCUTANEOUS ROD WAS ALSO PLACED USING THE INSTRUMENTS AND PRE-LOCKED. THE FOLLOWING COMPLICATIONS WERE REPORTED AS FOLLOWS: PRESENCE OF OBVIOUS PEDICLE SCREW POSITION DEVIATION OR EVEN NEEDING A SECOND REVISION SURGERY BECAUSE OF NON-STANDARD SURGICAL MANIPULATION. THE POSTOPERATIVE CT SCANS SHOWED THE LOCATION RELATIONSHIP BETWEEN VERTEBRAL PEDICLE SCREW (TOTAL NUMBER: 138) AND FACET JOINT: NO POINT, (N = 103); ONE POINT,(N = 22); TWO POINTS (N = 13). WHERE NO POINT INDICATED THE VERTEBRAL PEDICLE SCREW CLEARLY AVOIDS THE FACET JOINT, ONE POINT INDICATED THE VERTEBRAL PEDICLE SCREW HEAD IS EITHER IN CONTACT WITH OR SUSPECTED TO HAS INVADED THE FACET JOINT, AND TWO POINTS INDICATE THE SCREW HAS CLEARLY INVADED THE FACET JOINT. THIS REPORT IS FOR AN UNKNOWN DEPUY SPINE VIPER 2 SYSTEM. THIS REPORT IS FOR ONE (1) UNKNOWN MONO/POLYAXIAL SCREW. THIS IS REPORT 3 OF 3 FOR (B)(4).

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1352744 UNKNOWN MONO/POLYAXIAL SCREWS ORTHOSIS, SPINAL PEDICLE FIXATION, FOR DDD NKB MEDOS INTERNATIONAL SàRL CH

Patients

Seq Age Sex Outcome Treatment
1