CEPHEID XPERT XPRESS SARS-COV-2
Report
- Report Number
- 3004530258-2021-00300
- Event Type
- Malfunction
- Date Received
- September 8, 2021
- Date of Event
- July 13, 2020
- Report Date
- September 2, 2021
- Manufacturer
- CEPHEID
- Product Code
- QJR
- PMA / PMN Number
- EUA200035
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- SC, US
- Reporter Occupation
- 501
Narratives
THIS MDR IS BEING FILED IN ACCORDANCE WITH THE ADDITIONAL REPORTING CONDITIONS INCLUDED IN CEPHEID'S EMERGENCY USE AUTHORIZATION (EUA) FOR THIS ASSAY. IN ADDITION TO THE EXISTING REPORTING REQUIREMENTS UNDER THE MDR REGULATION (21 CFR 803), FDA'S EUA AUTHORIZATION LETTER REQUIRES CEPHEID TO REPORT TO FDA ANY SUSPECTED OCCURRENCE OF FALSE POSITIVE AND FALSE NEGATIVE RESULTS AND SIGNIFICANT DEVIATIONS FROM THE ESTABLISHED PERFORMANCE CHARACTERISTICS OF THE PRODUCT. US CUSTOMER CONTACTED CEPHEID TO DISCUSS PATIENT RESULTS FOR XPERT XPRESS SARS-COV-2 TESTED ON THE GENEXPERT INSTRUMENT. CUSTOMER COLLECTED SAMPLES FROM A PATIENT WITH NO SYMPTOMS OF COVID-19. CUSTOMER REPORTED THAT ASYMPTOMATIC PATIENT WAS TESTED 6 TIMES USING XPERT XPRESS SARS-COV-2 AND 2 TIMES USING LABCORP TESTS FROM (B)(6) 2020 TO (B)(6) 2020. SAMPLE COLLECTED (B)(6) 2020 AND TESTED SAME DAY USING XPERT XPRESS SARS-COV-2, RESULTING IN SARS-COV-2 POSITIVE (REPORTED TO PHYSICIAN). RETEST WAS RUN AT LABCORP ON UNKNOWN DATE USING UNKNOWN METHOD, RESULTING IN SARS-COV-2 NEGATIVE (REPORTED TO PHYSICIAN). CUSTOMER REPORTED THAT SAMPLE WAS FROZEN BEFORE SENDING TO LABCORP, WHICH IS OFF-LABEL. CUSTOMER REPORTED THAT THIS WAS THE ONLY DISCREPANT RESULT BETWEEN XPERT XPRESS SARS-COV-2 VERSUS LABCORP. REVIEW OF DATA PROVIDED BY THE CUSTOMER SHOWED NORMAL AMPLIFICATION CURVES. CEPHEID PATIENT SAFETY BOARD NOTES THAT TEST RESULTS SHOW GRADUALLY DECLINING VIRAL TITERS OVER TIME LEADING UP TO DISCREPANT TEST RESULT. ROOT CAUSE IS DUE TO TARGET NEAR LOD. THERE IS NO EVIDENCE OF PRODUCT MALFUNCTION AND THERE WAS NO REPORTED PATIENT HARM. FALSE POSITIVE RESULTS FOR SARS-COV-2 COULD LEAD TO INCORRECT MANAGEMENT OF SYMPTOMATIC PATIENTS, INCLUDING UNNECESSARY ISOLATION OR QUARANTINE, MISALLOCATION OF RESOURCES, DELAYED DIAGNOSIS AND TREATMENT FOR OTHER INFECTIONS OR HEALTH CONDITIONS, OR UNNECESSARY ANTIVIRAL TREATMENT. CEPHEID'S PATIENT SAFETY BOARD CONSULT CONFIRMED WITH THE CUSTOMER THAT THERE WAS NO ASSOCIATED PATIENT HARM OR CHANGE TO PATIENT TREATMENT. RESULTS ARE FOR THE IDENTIFICATION OF SARS-COV-2 RNA. AS PER SECTION 3 OF XPERT XPRESS SARS-COV-2 EUA IFU; POSITIVE RESULTS ARE INDICATIVE OF THE PRESENCE OF SARS-COV-2; CLINICAL CORRELATION WITH PATIENT HISTORY AND OTHER DIAGNOSTIC INFORMATION IS NECESSARY TO DETERMINE PATIENT INFECTION STATUS. NOTE FOR DEVICE EVALUATED BY MANUFACTURER - ANSWER OF NO IS DUE TO THE SINGLE USE OF THE XPERT XPRESS SARS-COV-2 TEST AND THE UNAVAILABILITY OF THAT PRODUCT LOT TO BE RETURNED TO CEPHEID.
THIS MDR IS BEING FILED IN ACCORDANCE WITH THE ADDITIONAL REPORTING CONDITIONS INCLUDED IN CEPHEID'S EMERGENCY USE AUTHORIZATION (EUA) FOR THIS ASSAY. IN ADDITION TO THE EXISTING REPORTING REQUIREMENTS UNDER THE MDR REGULATION (21 CFR 803), FDA'S EUA AUTHORIZATION LETTER REQUIRES CEPHEID TO REPORT TO FDA ANY SUSPECTED OCCURRENCE OF FALSE POSITIVE AND FALSE NEGATIVE RESULTS AND SIGNIFICANT DEVIATIONS FROM THE ESTABLISHED PERFORMANCE CHARACTERISTICS OF THE PRODUCT. US CUSTOMER CONTACTED CEPHEID TO DISCUSS PATIENT RESULTS FOR XPERT XPRESS SARS-COV-2 TESTED ON THE GENEXPERT INSTRUMENT. CUSTOMER COLLECTED SAMPLES FROM A PATIENT WITH NO SYMPTOMS OF COVID-19. CUSTOMER REPORTED THAT ASYMPTOMATIC PATIENT WAS TESTED 6 TIMES USING XPERT XPRESS SARS-COV-2 AND 2 TIMES USING LABCORP TESTS FROM (B)(6) 2020 TO (B)(6) 2020. SAMPLE COLLECTED (B)(6) 2020 AND TESTED SAME DAY USING XPERT XPRESS SARS-COV-2, RESULTING IN SARS-COV-2 POSITIVE (REPORTED TO PHYSICIAN). RETEST WAS RUN AT LABCORP ON UNKNOWN DATE USING UNKNOWN METHOD, RESULTING IN SARS-COV-2 NEGATIVE (REPORTED TO PHYSICIAN). CUSTOMER REPORTED THAT SAMPLE WAS FROZEN BEFORE SENDING TO LABCORP, WHICH IS OFF-LABEL. CUSTOMER REPORTED THAT THIS WAS THE ONLY DISCREPANT RESULT BETWEEN XPERT XPRESS SARS-COV-2 VERSUS LABCORP. REVIEW OF DATA PROVIDED BY THE CUSTOMER SHOWED NO EVIDENCE OF PRODUCT MALFUNCTION AND THERE WAS NO REPORTED PATIENT HARM.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1334813 | CEPHEID XPERT XPRESS SARS-COV-2 | COVID-19 RT-PCR TEST | QJR | CEPHEID | 1000199243 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 |