FDA Adverse Event Injury Summary report: N

UNK - CONSTRUCTS: EXPEDIUM

MDR report key: 12442048 · Received September 8, 2021

Report

Report Number
1526439-2021-01888
Event Type
Injury
Date Received
September 8, 2021
Report Date
August 9, 2021
Manufacturer
MEDOS INTERNATIONAL SàRL CH
Product Code
MNH
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
FL, US
Reporter Occupation
PHYSICIAN

Narratives

Additional Manufacturer Narrative · 0

DEPUY SYNTHES IS SUBMITTING THIS REPORT PURSUANT TO THE PROVISIONS OF 21 CFR, PART 803. THIS REPORT MAY BE BASED ON INFORMATION WHICH DEPUY SYNTHES HAS NOT BEEN ABLE TO INVESTIGATE OR VERIFY PRIOR TO THE REQUIRED REPORTING DATE. THIS REPORT DOES NOT REFLECT A CONCLUSION BY FDA, DEPUY SYNTHES OR ITS EMPLOYEES THAT THE REPORT CONSTITUTES AN ADMISSION THAT THE DEVICE, DEPUY SYNTHES, OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE POTENTIAL EVENT DESCRIBED IN THIS REPORT. IF THE INFORMATION IS UNKNOWN, NOT AVAILABLE OR DOES NOT APPLY, THE SECTION/FIELD OF THE FORM IS LEFT BLANK. DEVICE WAS USED FOR TREATMENT, NOT DIAGNOSIS. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE.

Additional Manufacturer Narrative · 1

ADDITIONAL NARRATIVE: 510K: THIS REPORT IS FOR AN UNK MONO/POLYAXIAL SCREWS/UNKNOWN LOT. PART AND LOT NUMBERS ARE UNKNOWN; UDI NUMBER IS UNKNOWN. COMPLAINANT PART IS NOT EXPECTED TO BE RETURNED FOR MANUFACTURER REVIEW/INVESTIGATION. WITHOUT A LOT NUMBER THE DEVICE HISTORY RECORDS REVIEW COULD NOT BE COMPLETED. PRODUCT WAS NOT RETURNED. BASED ON THE INFORMATION AVAILABLE, IT HAS BEEN DETERMINED THAT NO CORRECTIVE AND/OR PREVENTATIVE ACTION IS PROPOSED. THIS COMPLAINT WILL BE ACCOUNTED FOR AND MONITORED VIA POST MARKET SURVEILLANCE ACTIVITIES. IF ADDITIONAL INFORMATION IS MADE AVAILABLE, THE INVESTIGATION WILL BE UPDATED AS APPLICABLE. DEVICE WAS USED FOR TREATMENT, NOT DIAGNOSIS. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE.

Description of Event or Problem · 1

THIS REPORT IS BEING FILED AFTER THE REVIEW OF THE FOLLOWING JOURNAL ARTICLE: WANG, M.Y. ET AL (2010), AN ANALYSIS OF THE DIFFERENCES IN THE ACUTE HOSPITALIZATION CHARGES FOLLOWING MINIMALLY INVASIVE VERSUS OPEN POSTERIOR LUMBAR INTERBODY FUSION, JOURNAL OF NEUROSURGERY: SPINE, VOL 12 (XX), PAGES 694¿699 (USA). THE AIM OF THIS RETROSPECTIVE STUDY IS TO REVIEW THE AUTHOR'S EXPERIENCES WITH HOSPITALIZATION COSTS AT AN ACADEMIC MEDICAL CENTER. DURING A 14-MONTH PERIOD, A TOTAL OF 74 PATIENTS (MEAN AGE 55 YEARS) WERE INCLUDED IN THE STUDY. THE SERIES INCLUDED 59 SINGLE-LEVEL OPERATIONS (75% MIS AND 25% OPEN), AND 15 2-LEVEL SURGERIES (53% MIS AND 47% OPEN). THE OPEN PROCEDURE WAS PERFORMED USING POLYAXIAL TITANIUM EXPEDIUM TRANSPEDICULAR SCREWS (DEPUY SPINE, INC.) AND FOR MIS, VIPER PEDICLE SCREW (DEPUY SPINE, INC.) WAS USED. ALL OPERATIONS INCLUDED BILATERAL TRANSPEDICULAR SCREW-ROD FIXATION. THE MEAN FOLLOW-UP PERIOD WAS UNKNOWN. THE FOLLOWING COMPLICATIONS WERE REPORTED AS FOLLOWS: OPEN GROUP: 6.7% AND 14.2% OF THE PATIENT IN THE SINGLE-LEVEL AND 2-LEVEL SURGERIES HAD DURAL TEARS. 6.7% OF THE PATIENT IN THE SINGLE-LEVEL HAD NEUROLOGICAL DEFICIT. 14.2% IN THE 2-LEVEL HAD PULMONARY COMPLICATIONS. 28.6% OF THE PATIENTS IN THE 2-LEVEL HAD CARDIAC COMPLICATIONS. 14.2% OF THE PATIENTS IN THE 2-LEVEL HAD WOUND INFECTION. MIS GROUP: 4.5% OF THE PATIENTS IN THE SINGLE-LEVEL HAD NEUROLOGICAL DEFICIT. 12.5% OF THE PATIENTS IN THE 2-LEVEL HAD CARDIAC COMPLICATIONS. 12.5% OF THE PATIENTS IN THE 2-LEVEL HAD DURAL TEARS. THIS REPORT IS FOR AN UNKNOWN DEPUY SPINE EXPEDIUM CONSTRUCTS AND UNKNOWN DEPUY SPINE VIPER CONSTRUCTS. A COPY OF THE LITERATURE ARTICLE IS BEING SUBMITTED WITH THIS MEDWATCH. THIS REPORT IS FOR ONE (1) UNK MONO/POLYAXIAL SCREWS. THIS IS REPORT 2 OF 2 FOR COMPLAINT (B)(4).

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1337300 UNK - CONSTRUCTS: EXPEDIUM ORTHOSIS, SPONDYLOSTHESIS SPINAL FIXATION MNH MEDOS INTERNATIONAL SàRL CH

Patients

Seq Age Sex Outcome Treatment
1 Required Intervention