FDA Adverse Event Malfunction Summary report: N

CEPHEID XPERT XPRESS SARS-COV-2

MDR report key: 12389542 · Received August 30, 2021

Report

Report Number
3004530258-2021-00262
Event Type
Malfunction
Date Received
August 30, 2021
Date of Event
August 20, 2020
Report Date
August 30, 2021
Manufacturer
CEPHEID
Product Code
QJR
PMA / PMN Number
EUA200035
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
NY, US
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 0

THIS MDR IS BEING FILED IN ACCORDANCE WITH THE ADDITIONAL REPORTING CONDITIONS INCLUDED IN CEPHEID'S EMERGENCY USE AUTHORIZATION (EUA) FOR THIS ASSAY. IN ADDITION TO THE EXISTING REPORTING REQUIREMENTS UNDER THE MDR REGULATION (21 CFR 803), FDA'S EUA AUTHORIZATION LETTER REQUIRES CEPHEID TO REPORT TO FDA ANY SUSPECTED OCCURRENCE OF FALSE POSITIVE AND FALSE NEGATIVE RESULTS AND SIGNIFICANT DEVIATIONS FROM THE ESTABLISHED PERFORMANCE CHARACTERISTICS OF THE PRODUCT. US CUSTOMER CONTACTED CEPHEID TO DISCUSS PATIENT RESULTS FOR XPERT XPRESS SARS-COV-2 TESTED ON THE GENEXPERT INSTRUMENT. CUSTOMER COLLECTED SAMPLES FROM A PATIENT WITH UNCONFIRMED STATUS REGARDING SYMPTOMS OF COVID-19. SAMPLE-1 WAS COLLECTED (B)(6) 2020 AND TESTED SAME DAY USING XPERT XPRESS SARS-COV-2, RESULTING IN SARS-COV-2 POSITIVE (REPORTED TO PHYSICIAN). SAMPLE-2 WAS COLLECTED (B)(6) 2020 AND TESTED RUN (B)(6) 2020 USING UNKNOWN NAAT, RESULTING IN SARS-COV-2 NEGATIVE (UNKNOWN IF REPORTED TO PHYSICIAN). SAMPLE-3 WAS COLLECTED ON UNKNOWN DATE AND TEST UNKNOWN DATE USING XPERT XPRESS SARS-COV-2, RESULTING IN SARS-COV-2 NEGATIVE (UNKNOWN IF REPORTED TO PHYSICIAN). CUSTOMER REPORTS THAT PATIENT ALSO TESTED POSITIVE WITH AN ANTIBODY TEST. REVIEW OF DATA PROVIDED BY THE CUSTOMER SHOWED NORMAL AMPLIFICATION CURVES. ROOT CAUSE IS DUE TO LOW CONCENTRATION OF TARGET ORGANISM THAT IS NOT LOD-RELATED. THERE IS NO EVIDENCE OF PRODUCT MALFUNCTION AND THERE WAS NO REPORTED PATIENT HARM. FALSE POSITIVE RESULTS FOR SARS-COV-2 COULD LEAD TO INCORRECT MANAGEMENT OF SYMPTOMATIC PATIENTS, INCLUDING UNNECESSARY ISOLATION OR QUARANTINE, MISALLOCATION OF RESOURCES, DELAYED DIAGNOSIS AND TREATMENT FOR OTHER INFECTIONS OR HEALTH CONDITIONS, OR UNNECESSARY ANTIVIRAL TREATMENT. CEPHEID'S PATIENT SAFETY BOARD CONSULT CONFIRMED WITH THE CUSTOMER THAT THERE WAS NO ASSOCIATED PATIENT HARM OR CHANGE TO PATIENT TREATMENT. RESULTS ARE FOR THE IDENTIFICATION OF SARS-COV-2 RNA. AS PER SECTION 3 OF XPERT XPRESS SARS-COV-2 EUA IFU; POSITIVE RESULTS ARE INDICATIVE OF THE PRESENCE OF SARS-COV-2; CLINICAL CORRELATION WITH PATIENT HISTORY AND OTHER DIAGNOSTIC INFORMATION IS NECESSARY TO DETERMINE PATIENT INFECTION STATUS. NOTE DEVICE EVALUATED BY MANUFACTURER - ANSWER OF NO IS DUE TO THE SINGLE USE OF THE XPERT XPRESS SARS-COV-2 TEST AND THE UNAVAILABILITY OF THAT PRODUCT LOT TO BE RETURNED TO CEPHEID.

Description of Event or Problem · 0

THIS MDR IS BEING FILED IN ACCORDANCE WITH THE ADDITIONAL REPORTING CONDITIONS INCLUDED IN CEPHEID'S EMERGENCY USE AUTHORIZATION (EUA) FOR THIS ASSAY. IN ADDITION TO THE EXISTING REPORTING REQUIREMENTS UNDER THE MDR REGULATION (21 CFR 803), FDA'S EUA AUTHORIZATION LETTER REQUIRES CEPHEID TO REPORT TO FDA ANY SUSPECTED OCCURRENCE OF FALSE POSITIVE AND FALSE NEGATIVE RESULTS AND SIGNIFICANT DEVIATIONS FROM THE ESTABLISHED PERFORMANCE CHARACTERISTICS OF THE PRODUCT. US CUSTOMER CONTACTED CEPHEID TO DISCUSS PATIENT RESULTS FOR XPERT XPRESS SARS-COV-2 TESTED ON THE GENEXPERT INSTRUMENT. CUSTOMER COLLECTED SAMPLES FROM A PATIENT WITH UNCONFIRMED STATUS REGARDING SYMPTOMS OF COVID-19. SAMPLE-1 WAS COLLECTED (B)(6) 2020 AND TESTED SAME DAY USING XPERT XPRESS SARS-COV-2, RESULTING IN SARS-COV-2 POSITIVE (REPORTED TO PHYSICIAN). SAMPLE-2 WAS COLLECTED (B)(6) 2020 AND TESTED RUN (B)(6) 2020 USING UNKNOWN NAAT, RESULTING IN SARS-COV-2 NEGATIVE (UNKNOWN IF REPORTED TO PHYSICIAN). SAMPLE-3 WAS COLLECTED ON UNKNOWN DATE AND TEST UNKNOWN DATE USING XPERT XPRESS SARS-COV-2, RESULTING IN SARS-COV-2 NEGATIVE (UNKNOWN IF REPORTED TO PHYSICIAN). CUSTOMER REPORTS THAT PATIENT ALSO TESTED POSITIVE WITH AN ANTIBODY TEST. REVIEW OF DATA PROVIDED BY THE CUSTOMER SHOWED NO EVIDENCE OF PRODUCT MALFUNCTION AND THERE WAS NO REPORTED PATIENT HARM.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1286549 CEPHEID XPERT XPRESS SARS-COV-2 COVID-19 RT-PCR TEST QJR CEPHEID 1000207311

Patients

Seq Age Sex Outcome Treatment
1