FDA Adverse Event Injury Summary report: N

4 WHEEL SCOOTER

MDR report key: 12354143 · Received August 20, 2021

Report

Report Number
MW5103416
Event Type
Injury
Date Received
August 20, 2021
Date of Event
August 19, 2021
Report Date
August 20, 2021
Manufacturer
GOLDEN TECHNOLOGIES, INC. / GOLDEN BROTHERS, INC.
Product Code
INI
Product Problem
Yes
Report Source
Voluntary report
Reporter Location
IN
Reporter Occupation
003

Narratives

Description of Event or Problem · 1

CALLER STATED EARLY THIS YEAR WHEN HE PUSHED HIS 4-WHEEL SCOOTER TO GO FORWARD IT GETS A CLICKING SOUND AND THEN THE SCOOTER GOES INTO FULL REVERSE. HE TRIED STOPPING IT ON THIS DAY USING THE PADDLE CONTROL BUT IT DID NOT STOP. HE CONTACTED THE MANUFACTURER AND WAS ASKED TO RETURN THE DEVICE FOR REPAIRS. AFTER THREE WITH THE MANUFACTURER THE SCOOTER WAS RETURNED BACK TO THE CALLER BUT THE PROBLEM PERSIST. A NEW CONTROLLER AND PADDLE WAS SENT TO THE CALLER AND INSTALLED INTO THE SCOOTER, BUT THE SCOOTER STILL DID NOT WORK CORRECTLY. YESTERDAY (B)(6) 2021 CALLER STATED THAT HE WAS DRIVING THE SCOOTER AND THE SAME PROBLEM HAPPENED BUT THIS TIME HE WAS THROWN OFF THE SCOOTER WHERE HE SUSTAINED INJURIES ALL OVER HIS BODY AND EXPERIENCED PAIN. THE SCOOTER IS NOW DAMAGED THAT HE COULD NOT TURN IT TO THE LEFT OR RIGHT.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1243698 4 WHEEL SCOOTER VEHICLE, MOTORIZED 3-WHEELED INI GOLDEN TECHNOLOGIES, INC. / GOLDEN BROTHERS, INC. GA541

Patients

Seq Age Sex Outcome Treatment
1 65 YR Required Intervention