FDA Adverse Event Malfunction Summary report: N

MONOMEND MAX 2/0 (3)70CM HS37S(M)VPL DDP

MDR report key: 12317338 · Received August 13, 2021

Report

Report Number
3003639970-2021-00389
Event Type
Malfunction
Date Received
August 13, 2021
Report Date
October 8, 2021
Manufacturer
B. BRAUN SURGICAL, S.A.
Product Code
NEW
PMA / PMN Number
SEE H10
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
US
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 0

ANALYSIS AND RESULTS: WE HAVE NOT RECEIVED THE POSSIBLE INVOLVED BATCHES. WITHOUT CLOSED SAMPLES AND/OR DEFECTIVE SAMPLES A PROPER ANALYSIS CANNOT BE PERFORMED. MOREOVER, THE BATCH MANUFACTURING RECORDS CANNOT BE REVIEWED EITHER. FINAL CONCLUSION: WITHOUT SAMPLES WE ARE NOT IN POSITION OF STUDYING IF THE AFFECTED PRODUCT DOES NOT FULFIL THE SPECIFICATIONS. IN CONSEQUENCE, A PROPER ANALYSIS CANNOT BE DONE AND THE CASE IS NOT CONFIRMED DUE TO LACK OF EVIDENCE. NEVERTHELESS, WE TAKE NOTE OF THIS INCIDENCE AND IF ANY SAMPLE IS RECEIVED IN THE FUTURE, WE WILL RE-OPEN THE CASE AND ANALYSE IT. PLEASE NOTE THAT WHEN NO SAMPLES ARE RECEIVED OUR ANALYSIS IS VERY LIMITED. WE REGRET ANY INCONVENIENCE THIS ISSUE MAY HAVE CAUSED AND THANK YOU FOR YOUR COLLABORATION. ACTIONS ON PRODUCT DISTRIBUTED OF THIS REFERENCE/BATCH: BASED ON THE CONCLUSION DERIVED FROM INVESTIGATION, IT IS NOT REQUIRED TO MAKE ACTIONS IN DISTRIBUTED PRODUCT. CORRECTIVE/PREVENTIVE ACTIONS: ACCORDING TO OUR INTERNAL PROCEDURES, THERE IS NO NEED TO ESTABLISH CORRECTIVE OR PREVENTIVE ACTIONS. NEVERTHELESS, THIS COMPLAINT IS RECORDED FOR TRENDING ANALYSIS TO ASSESS IF ACTIONS ARE NEEDED IN THE FUTURE.

Additional Manufacturer Narrative · 1

REPORTED DEVICE MARKETED IN THE U.S. ONLY FOR VETERINARY USE, HOWEVER, SIMILAR DEVICES OR DEVICES THAT SHARE COMPONENTS, RAW MATERIALS, PROCESS METHODS OR OTHER TECHNOLOGICAL CHARACTERISTICS ARE REGISTERED WITHIN THE U.S. K031216. IF ADDITIONAL INFORMATION BECOMES AVAILABLE A FOLLOW-UP REPORT WILL BE SUBMITTED.

Description of Event or Problem · 1

IT WAS REPORTED AN ISSUE WITH MONOMEND SUTURE. THE CLIENT (VETERINARIAN) REPORTED TWO SEPARATE SPAY COMPLICATIONS DUE TO DEHISCENCE WITH THE SUTURES. RELATED CASE: 3003639970-2021-00388. NO MORE INFORMATION HAS BEEN PROVIDED.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1218615 MONOMEND MAX 2/0 (3)70CM HS37S(M)VPL DDP SYNTHETIC ABSORBABLE MONOFILAR SUTURE NEW B. BRAUN SURGICAL, S.A. 40007

Patients

Seq Age Sex Outcome Treatment
1