FDA Adverse Event Injury Summary report: N

MONOCRYL POLIGLECAPRONE 25 SUTURE UNKNOWN PRODUCT

MDR report key: 12309987 · Received August 11, 2021

Report

Report Number
2210968-2021-07245
Event Type
Injury
Date Received
August 11, 2021
Date of Event
October 19, 2020
Report Date
July 29, 2021
Manufacturer
ETHICON INC.
Product Code
GAN
PMA / PMN Number
K960653
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
NL
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 1

(B)(4). ATTEMPTS ARE BEING MADE TO CLARIFY THE FOLLOWING INFORMATION. TO DATE NO RESPONSE HAS BEEN PROVIDED. IF FURTHER DETAILS ARE RECEIVED AT A LATER DATE A SUPPLEMENTAL MEDWATCH WILL BE SENT. DOES THE SURGEON BELIEVE THAT ANY OF THE ETHICON PRODUCTS INVOLVED CAUSED AND/OR CONTRIBUTED TO THE POST-OPERATIVE COMPLICATIONS DESCRIBED IN THE ARTICLE? DOES THE SURGEON BELIEVE THERE WAS ANY DEFICIENCY WITH ANY OF THE ETHICON PRODUCTS USED IN THIS PROCEDURE? IF SO, PLEASE PROVIDE DETAILS. WERE THE CASES DISCUSSED IN THIS ARTICLE PREVIOUSLY REPORTED TO ETHICON? IF YES, PLEASE PROVIDE A COMPLAINT REFERENCE NUMBER. PATIENT DEMOGRAPHICS? THIS REPORT IS RELATED TO A JOURNAL ARTICLE; THEREFORE, NO PRODUCT WILL BE RETURNED FOR ANALYSIS AND THE BATCH HISTORY RECORDS CANNOT BE REVIEWED AS THE LOT NUMBER HAS NOT BEEN PROVIDED. (B)(4). THE SINGLE COMPLAINT WAS REPORTED WITH MULTIPLE EVENTS. THERE ARE NO ADDITIONAL DETAILS REGARDING THE ADDITIONAL EVENTS. RELATED EVENTS CAPTURED VIA 2210968-2021-07246. CITATION: ANN SURG ONCOL (2021) 28:2599¿2608 HTTPS://DOI.ORG/10.1245/S10434-020-09225-8.

Description of Event or Problem · 1

TITLE: REDUCING SEROMA FORMATION AND ITS SEQUELAE AFTER MASTECTOMY BY CLOSURE OF THE DEAD SPACE: A MULTI-CENTER, DOUBLE-BLIND RANDOMIZED CONTROLLED TRIAL (SAM-TRIAL). THIS STUDY AIMED TO ASSESS THE EFFECT OF FLAP FIXATION USING SUTURES OR TISSUE GLUE IN PREVENTING SEROMA FORMATION AND ITS SEQUELAE. BETWEEN JUNE 2014 AND JULY 2018, A TOTAL OF 339 PATIENTS UNDERWENT ONE OF THREE STUDY ARMS: CONVENTIONAL CLOSURE (CON; N = 115, 33.9%), FLAP FIXATION WITH SUTURES (FFS; N = 111, 32.7%), OR FLAP FIXATION WITH TISSUE GLUE (FFG; N = 113, 33.3%). FOR SKIN CLOSURE, THE EDGES WERE SUTURED USING ABSORBABLE MONOFILAMENT SUTURES (MONOCRYL 3.0). VICRYL 3.0 WAS USED FOR FLAP FIXATION USING SUTURES. (N=40) SEROMA THUS HAD SEROMA ASPIRATIONS. (N=56) SURGICAL SITE INFECTION. THEY WERE TREATED WITH ANTIBIOTICS. (N=30) REOPERATION. (N=?) SLIGHT DETERIORATION OF SHOULDER FUNCTION. FLAP FIXATION USING SUTURES LEADS TO A SIGNIFICANT REDUCTION IN ASPIRATIONS OF POST-MASTECTOMY SEROMAS.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1203936 MONOCRYL POLIGLECAPRONE 25 SUTURE UNKNOWN PRODUCT SUTURE, ABSORBABLE, SYNTHETIC GAN ETHICON INC.

Patients

Seq Age Sex Outcome Treatment
1 Required Intervention