FDA Adverse Event Injury Summary report: N

COLLEAGUE CX TRIPLE CHANNEL VOLUMETRIC INFUSION PUMP

MDR report key: 1230097 · Received November 17, 2008

Report

Report Number
6000001-2007-88568
Event Type
Injury
Date Received
November 17, 2008
Date of Event
June 18, 2007
Report Date
June 19, 2007
Manufacturer
BAXTER HEALTHCARE PTE. LTD.
Product Code
FRN
PMA / PMN Number
K010566
Removal / Correction Number
600001-06/21/07-004-R
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
WI, US
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 1

EVALUATION SUMMARY: THIS REPORT IS BEING RESUBMITTED IN ACCORDANCE WITH INSTRUCTIONS FROM FDA TO ADDRESS A MANUFACTURER REPORT SEQUENCE NUMBER ISSUE THAT OCCURRED WHEN THIS MDR OR SUPPLEMENT WAS ORIGINALLY SUBMITTED TO THE FDA ON JUN 26 2007. A REQUEST FOR THE RETURN OF THE DEVICE HAS BEEN MADE. A FOLLOW-UP REPORT WILL BE FILED UPON COMPLETION OF AN EVALUATION OR IF ANY ADDITIONAL INFORMATION BECOMES AVAILABLE. THE 16:310:867:0002 IS DUE TO A SOFTWARE "MAILBOX", THAT STORES TEMPORARY DATA UNTIL IT CAN BE PROCESSED, BECOMING FILLED. THE ISSUE IDENTIFIED ABOVE HAS BEEN REPRODUCED IN OUR FACILITY WITH USER INTERFACE SOFTWARE VERSIONS 5.09.90 AND 6.13.90. PRELIMINARY ANALYSIS INDICATES THAT THIS ISSUE OCCURS ON TRIPLE CHANNEL DEVICES, DURING USER PROGRAMMING, WITH THREE CHANNELS INFUSING, IN SPECIFIC USE CASE SCENARIOS. ANALYSIS OF FIELD INFORMATION AND THE DATA, EVENT LOGS AND THE ISSUE INVESTIGATION HAVE NOT SHOWN THAT THE ISSUE WILL OCCUR ON PREVIOUS SOFTWARE VERSIONS IN THE SAME USE CASE SCENARIO. THERE IS NO EVIDENCE THAT THIS CAN OCCUR ON SINGLE CHANNEL DEVICES. ROOT CAUSE INVESTIGATIONS ARE CONTINUING. REVIEW OF THE COMPLAINT HISTORY REVEALS SIMILAR REPORTS HAVE BEEN RECEIVED FOR THIS PRODUCT FOR THE REPORTED ISSUE. THIS ISSUE IS BEING INVESTIGATED UNDER CAPA. PLEASE NOTE, IN REFERENCE TO THE "COLLEAGUE TRIPLE CHANNEL" ISSUE DESCRIBED IN THIS REPORT, AND BASED ON THE REVIEW OF RELEVANT COMPLAINT HISTORY OF THIS AND SIMILAR EVENTS, BAXTER DECIDED IN 2007, TO TAKE "REMEDIAL ACTION" TO PREVENT RISK OF HARM TO THE PUBLIC HEALTH. BASED ON THIS DECISION, A 5-DAY MDR WAS INITIATED FOR ALL EVENTS ASSOCIATED WITH THIS ISSUE. AS SUCH, THE AWARE DATE IS 2007, FOR ALL REPORTED EVENTS RECEIVED PRIOR TO THIS DATE.

Description of Event or Problem · 1

BAXTER SALES REPRESENTATIVE CALLED TO REPORT THAT THE FACILITY HAD CONTACTED HAD REPORTED A COLLEAGUE TRIPLE CHANNEL PUMP HAD FAILED DURING OPEN HEART SURGERY DURING PATIENT USE. THE MEDICATIONS INFUSING WERE EPINEPHRINE, NOREPHRINE AND PHENYLEPHRINE (CONCENTRATION, DOSE, RATE AND VOLUME UNKNONW). THE PUMP ALARMED FAIL CODE 16:310 AND ALL THREE CHANNELS FAILED. THE PATIENT'S BLOOD PRESSURE DROPPED AND INTERVENTION (UNKNOWN) WAS PROVIDED TO RESTORE THE PATIENT'S BLOOD PRESSURE. THE PATIENT RESPONDED TO THE INTERVENTION AND REMAINS HOSPITALIZED. THE PATIENT WAS SWITCHED TO A 2ND COLLEAGUE PUMP AFTER THIS INCIDENT. THIS IS THE FIRST OF THREE EVENTS INVOLVING THE SAME PATIENT ON THE SAME DATE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1 COLLEAGUE CX TRIPLE CHANNEL VOLUMETRIC INFUSION PUMP 80FRN FRN BAXTER HEALTHCARE PTE. LTD.

Patients

Seq Age Sex Outcome Treatment
1 81 YR Life Threatening| R