FDA Adverse Event Malfunction Summary report: N

INSERTION HANDLE FOR SUPRAPATELLAR

MDR report key: 12256524 · Received July 30, 2021

Report

Report Number
2939274-2021-04414
Event Type
Malfunction
Date Received
July 30, 2021
Date of Event
July 2, 2021
Report Date
July 2, 2021
Manufacturer
WRIGHTS LANE SYNTHES USA PRODUCTS LLC
Product Code
JDS
UDI-DI
10886982068828
PMA / PMN Number
K111667
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
CA, US
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 0

DEPUY SYNTHES IS SUBMITTING THIS REPORT PURSUANT TO THE PROVISIONS OF 21 CFR, PART 803. THIS REPORT MAY BE BASED ON INFORMATION WHICH DEPUY SYNTHES HAS NOT BEEN ABLE TO INVESTIGATE OR VERIFY PRIOR TO THE REQUIRED REPORTING DATE. THIS REPORT DOES NOT REFLECT A CONCLUSION BY FDA, DEPUY SYNTHES OR ITS EMPLOYEES THAT THE REPORT CONSTITUTES AN ADMISSION THAT THE DEVICE, DEPUY SYNTHES, OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE POTENTIAL EVENT DESCRIBED IN THIS REPORT. H3, H4, H6: PART # 03.010.440-US. LOT # 190164-101. MANUFACTURING SITE: SELZACH. RELEASE TO WAREHOUSE DATE: 05 JAN2018. SUPPLIER: LEITNER AG. A MANUFACTURING RECORD EVALUATION WAS PERFORMED FOR THE FINISHED ARTICLE LOT AND NO NON-CONFORMANCES WERE IDENTIFIED. VISUAL INSPECTION: THE INSERTION HANDLE FOR SUPRAPATELLAR (P/N: 03.010.440, LOT NUMBER: 190164-101) WAS RECEIVED AT US CUSTOMER QUALITY (CQ). UPON VISUAL INSPECTION, NO DAMAGE WAS OBSERVED. FUNCTIONAL TEST: A FUNCTIONAL ASSESSMENT WAS PERFORMED ON THE COMPLAINT DEVICE AND THE RETURNED MATING DEVICE. THE DEVICES CAN ASSEMBLE AND DISASSEMBLE, BUT WITH DIFFICULTY. THUS THE REPORTED CONDITION CAN BE REPLICATED. DIMENSIONAL INSPECTION: COMPLAINT RELEVANT DIMENSIONAL INSPECTION CANNOT BE PERFORMED DUE TO THE DEVICE GEOMETRY. DOCUMENT/SPECIFICATION REVIEW: MANUFACTURED AND CURRENT WERE REVIEWED. NO DESIGN ISSUES OR DISCREPANCIES WERE IDENTIFIED. COMPLAINT CONFIRMED? YES. INVESTIGATION CONCLUSION: THIS COMPLAINT IS CONFIRMED AS THE COMPLAINT DEVICE HAS DIFFICULTY ASSEMBLING TO THE MATING DEVICE. NO DEFINITIVE ROOT CAUSE COULD BE DETERMINED BASED ON THE PROVIDED INFORMATION. NO NEW, UNIQUE OR DIFFERENT PATIENT HARMS WERE IDENTIFIED AS A RESULT OF THIS EVALUATION. THERE WAS NO INDICATION THAT A DESIGN OR MANUFACTURING ISSUE CONTRIBUTED TO THE COMPLAINT. NO DESIGN ISSUES WERE OBSERVED DURING THE DOCUMENT/SPECIFICATION REVIEW. BASED ON THE INVESTIGATION FINDINGS, IT HAS BEEN DETERMINED THAT NO CORRECTIVE AND/OR PREVENTATIVE ACTION IS PROPOSED. ADDITIONAL MONITORING FOR ANY POTENTIAL SAFETY SIGNALS WILL BE CONDUCTED THROUGH COMPLAINT TRENDING AND OTHER POST MARKET SAFETY SURVEILLANCE ACTIVITIES. DEVICE WAS USED FOR TREATMENT, NOT DIAGNOSIS. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE.

Additional Manufacturer Narrative · 1

THE DEVICE WAS RECEIVED, THE INVESTIGATION COULD NOT BE COMPLETED, AND NO CONCLUSION COULD BE DRAWN, AS PRODUCT IS ENTERING THE COMPLAINT SYSTEM. DEVICE WAS USED FOR TREATMENT, NOT DIAGNOSIS. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE.

Description of Event or Problem · 1

IT WAS REPORTED THAT ON (B)(6) 2021, DURING AN INTRAMEDULLARY RODDING OF A TIBIA, IT WAS DISCOVERED THAT ATTACHMENT OF THE DEPUY SYNTHES SUPRAPATELLAR AIMING ARM WAS DIFFICULT TO ATTACH TO THE CORRESPONDING INSERTION HANDLE INTRA-OPERATIVELY. A MALLET WAS REQUIRED TO SEAT THE AIMING DEVICE APPROPRIATELY TO THE INSERTION HANDLE. UPON INSPECTION, IT APPEARS THE DOWELS ON THE AIMING ARM ARE OUT OF ALIGNMENT. THERE WAS NO SURGICAL DELAY. THE CASE WAS COMPLETED SUCCESSFULLY. NO PATIENT CONSEQUENCE. THIS REPORT IS FOR AN INSERTION HANDLE. THIS IS REPORT 2 OF 2 FOR (B)(4).

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1148762 INSERTION HANDLE FOR SUPRAPATELLAR NAIL, FIXATION, BONE JDS WRIGHTS LANE SYNTHES USA PRODUCTS LLC 03.010.440 90164-101 10886982068828

Patients

Seq Age Sex Outcome Treatment
1 AIMING ARM FOR SUPRAPATELLAR| UNK - IMPACTION INSTRUMENTS: HAMMER/MALLET: TRAUMA