FDA Adverse Event Malfunction Summary report: N

SALINE NORMAL 3ML PLASTIC TUBE

MDR report key: 12155871 · Received July 12, 2021

Report

Report Number
1119779-2021-01155
Event Type
Malfunction
Date Received
July 12, 2021
Date of Event
June 7, 2021
Report Date
March 31, 2022
Manufacturer
BECTON, DICKINSON & CO. (SPARKS)
Product Code
PPM
PMA / PMN Number
EXEMPT
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
CA, US
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

THE FOLLOWING FIELDS WERE UPDATED DUE TO ADDITIONAL INFORMATION: D10: DEVICE AVAILABLE FOR EVAL YES. D10: RETURNED TO MANUFACTURER ON: 2021-JUN-23 INVESTIGATION SUMMARY: THE BATCH HISTORY RECORD REVIEW FOR BATCH 1072960 WAS SATISFACTORY AND NO QUALITY NOTIFICATIONS WERE GENERATED DURING MANUFACTURING AND INSPECTION. FORMULATION, FILLING, AND TORQUING PROCESSES WERE WITHIN SPECIFICATIONS. QC INSPECTION AND TESTING WERE SATISFACTORY AT TIME OF RELEASE. THE RELEASE TESTING THAT IS PERFORMED ON THIS PRODUCT DOES INCLUDE MEDIA APPEARANCE. NO FOREIGN OBJECTS WERE OBSERVED IN QC SAMPLES AT THE TIME OF RELEASE. IF FOREIGN MATTER HAD BEEN NOTED DURING QC TESTING, THE PRODUCT WOULD HAVE BEEN PLACED ON QUALITY NOTIFICATION AND FURTHER ANALYSIS INCLUDING 100% INSPECTION OF THE BATCH WOULD HAVE BEEN CONDUCTED. COLOR AND CLARITY OF THIS PRODUCT IS ALSO EVALUATED PRIOR TO RELEASE TO ENSURE TO ENSURE THAT THEY CONFORM TO TYPICAL LEVELS. THE APPEARANCE OF THIS BATCH WAS SATISFACTORY PER INTERNAL PROCEDURES. AS PART OF THE RELEASE CRITERIA FOR THIS PRODUCT, THE BHR IS REVIEWED TO CONFIRM THE FOLLOWING: THE TOTAL ELAPSED TIME BETWEEN END OF FORMULATION AND START OF THE AUTOCLAVE CYCLE WAS WITHIN THE SPECIFIED LIMITS. ALL AUTOCLAVE PARAMETERS CONFORMED TO THE VALIDATED CYCLE PARAMETERS FOR THIS PRODUCT. THE MINIMUM F0 FOR THIS PRODUCT WAS MET. THE COMPLAINT HISTORY WAS REVIEWED, AND NO OTHER COMPLAINTS HAVE BEEN TAKEN ON THIS BATCH PER CUSTOMER. RETENTION SAMPLES FROM BATCH 1072960 WERE AVAILABLE FOR INSPECTION. NO MEDIA DEFECTS WERE OBSERVED IN 10/10 RETENTION SAMPLES. THERE WERE 10/10 PROPERLY AFFIXED LABELS ONE LABEL PER TUBE. FOR INVESTIGATION OF FILL VOLUME ALL 10/10 TUBES WERE MEASURED USING A WATER BLANK TUBE WITH THE ACCEPTABLE FILL VOLUME. ALL 10/10 TUBES MEASURED AT THE ACCEPTABLE FILL VOLUME LEVEL. FOR FURTHER INVESTIGATION TWO RETENTIONS WERE TESTED ONE TUBE WAS PLACED AT 20-25 DEGREE CELSIUS AND ONE TUBE WAS PLACED AT 33¿37-DEGREE CELSIUS INCUBATION FOR A TOTAL OF SEVEN DAYS. BY THE SEVENTH DAY OF INCUBATION NO MICROBIAL GROWTH OR PARTICLES WERE OBSERVED IN EITHER TUBE. NO PHOTOS WERE RECEIVED FROM THIS BATCH TO ASSIST WITH THE INVESTIGATION FOR THIS BATCH. TWO RETURN TUBES WERE ALSO INCUBATED. ONE TUBE AT 20-25 DEGREE CELSIUS AND ONE TUBE AT 33-37 DEGREES CELSIUS. AT THE END OF A SEVEN-DAY INCUBATION PERIOD NO MICROBIAL GROWTH WAS OBSERVED.

Description of Event or Problem · 0

IT WAS REPORTED THAT THE LABEL WAS ILLEGIBLE WITH SALINE NORMAL 3ML PLASTIC TUBE. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: (2 OF 2 COMPLAINTS) FOLDED/STAINED/WRINKLED LABELS.

Additional Manufacturer Narrative · 1

A DEVICE EVALUATION IS ANTICIPATED, BUT HAS NOT YET BEGUN. UPON COMPLETION OF THE INVESTIGATION, A SUPPLEMENTAL REPORT WILL BE FILED.

Description of Event or Problem · 1

IT WAS REPORTED THAT THE LABEL WAS ILLEGIBLE WITH SALINE NORMAL 3ML PLASTIC TUBE. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: (2 OF 2 COMPLAINTS). FOLDED/STAINED/WRINKLED LABELS.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1052886 SALINE NORMAL 3ML PLASTIC TUBE REAGENT, GENERAL PURPOSE PPM BECTON, DICKINSON & CO. (SPARKS) 1072960

Patients

Seq Age Sex Outcome Treatment
1 Unknown