YAMATO PLUS-R 7.5FR. 35CC IAB
Report
- Report Number
- 2248146-2021-00443
- Event Type
- Malfunction
- Date Received
- July 8, 2021
- Date of Event
- June 16, 2021
- Report Date
- November 17, 2021
- Manufacturer
- DATASCOPE CORP. - FAIRFIELD
- Product Code
- DSP
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- JA
- Reporter Occupation
- PHYSICIAN
- Health Professional
- Yes
Narratives
THE DEVICE HAS NOT BEEN RETURNED TO THE MANUFACTURER SO WE ARE UNABLE TO COMPLETE AN EVALUATION. ANALYSIS OF PRODUCTION (3331/213) - THE DEVICE HISTORY RECORDS REVIEW CONCLUDED THAT THERE WERE NO NCMRS, REWORK, OR DEVIATIONS DOCUMENTED FOR THE REPORTED LOT/SERIAL NUMBER. BASED ON THE REVIEW RESULTS, IT WAS DETERMINED THAT THERE IS NO RELATION BETWEEN THE MANUFACTURING PROCESS AND THE REPORTED FAILURE. HISTORICAL DATA ANALYSIS (4109/213) - THE REVIEW OF THE HISTORICAL DATA WAS PERFORMED. TREND ANALYSIS (4110/213) - THE OVERALL COMPLAINT TREND DATA FOR THE PERIOD JUL-2019 THROUGH JUN-2021 WAS REVIEWED. COMMUNICATION/INTERVIEWS: (4111/213) COMMUNICATION/INTERVIEWS WERE PERFORMED TO OBTAIN ALL POSSIBLE INFORMATION. REFERENCE COMPLAINT #(B)(4).
THE PRODUCT WAS RETURNED WITH THE MEMBRANE COMPLETELY UNFOLDED AND BLOOD ON THE EXTERIOR OF THE CATHETER. THE PRESSURE TUBING WAS ALSO RETURNED. NO BLOOD WAS VISIBLE INSIDE THE IAB CATHETER. ADDITIONALLY THE RETRACTION KIT WAS RETURNED UNUSED IN ITS PACKAGING. AN UNDERWATER LEAK TEST OF THE BALLOON, CATHETER, Y-FITTING, EXTRACORPOREAL AND PRESSURE TUBING WAS PERFORMED AND NO LEAKS WERE DETECTED. THE IAB WAS PLACED ON THE CS300 PUMP AND PUMPED FOR TWO HOURS WHICH REPRESENTS ONE COMPLETE AUTOFILL CYCLE. THE IAB PUMPED NORMALLY AND NO ALARM SOUNDED FROM THE PUMP. THE REPORTED EVENT CANNOT BE CONFIRMED BY THE EVALUATION. A NON-CONFORMING MATERIAL REPORT REVIEW WAS COMPLETED FOR THE REPORTED PRODUCT. NO NONCONFORMANCES WERE FOUND THAT ARE CONSIDERED TO BE RELATED TO THE EVENT. ANALYSIS OF PRODUCTION (3331/213) - THE DEVICE HISTORY RECORDS REVIEW CONCLUDED THAT THERE WERE NO NCMRS, REWORK, OR DEVIATIONS DOCUMENTED FOR THE REPORTED LOT/SERIAL NUMBER. BASED ON THE REVIEW RESULTS, IT WAS DETERMINED THAT THERE IS NO RELATION BETWEEN THE MANUFACTURING PROCESS AND THE REPORTED FAILURE. HISTORICAL DATA ANALYSIS (4109/213) - THE REVIEW OF THE HISTORICAL DATA WAS PERFORMED. TREND ANALYSIS (4110/213) - THE OVERALL COMPLAINT TREND DATA FOR THE PERIOD JUL-2019 THROUGH JUN-2021 WAS REVIEWED. COMMUNICATION/INTERVIEWS: (4111/213) COMMUNICATION/INTERVIEWS WERE PERFORMED TO OBTAIN ALL POSSIBLE INFORMATION. REFERENCE COMPLAINT #(B)(4).
THE DEVICE HAS BEEN RETURNED TO THE FACTORY AND IS BEING EVALUATED. A SUPPLEMENTAL REPORT WILL BE SUBMITTED WHEN THE EVALUATION IS COMPLETED. COMPLAINT RECORD ID # (B)(4).
N/A.
N/A
(B)(6). THE DEVICE HAS NOT BEEN RETURNED TO THE MANUFACTURER SO WE ARE UNABLE TO COMPLETE AN EVALUATION. IF PROVIDED WE WILL SEND A SUPPLEMENTAL REPORT WITH OUR ADDITIONAL FINDINGS. COMPLAINT RECORD ID # (B)(4).
IT WAS REPORTED THAT AFTER INSERTING THE INTRA-AORTIC BALLOON (IAB), THE CONSOLE GENERATED A LEAK IN IAB CIRCUIT ALARM. THE CONSOLE WAS SWAPPED OUT WITH A DIFFERENT ONE, BUT THE ISSUE CONTINUED. THE IAB WAS THEN REPLACED WITH A NEW ONE AND THERAPY WAS CONTINUED SUCCESSFULLY. THERE WAS NO PATIENT HARM OR ADVERSE EVENT REPORTED.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1035175 | YAMATO PLUS-R 7.5FR. 35CC IAB | SYSTEM, BALLOON, INTRA-AORTIC AND CONTROL | DSP | DATASCOPE CORP. - FAIRFIELD | 3000071396 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Unknown | UNKNOWN. |