FDA Adverse Event Malfunction Summary report: N

YAMATO PLUS-R 7.5FR. 35CC IAB

MDR report key: 12135126 · Received July 8, 2021

Report

Report Number
2248146-2021-00443
Event Type
Malfunction
Date Received
July 8, 2021
Date of Event
June 16, 2021
Report Date
November 17, 2021
Manufacturer
DATASCOPE CORP. - FAIRFIELD
Product Code
DSP
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
JA
Reporter Occupation
PHYSICIAN
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

THE DEVICE HAS NOT BEEN RETURNED TO THE MANUFACTURER SO WE ARE UNABLE TO COMPLETE AN EVALUATION. ANALYSIS OF PRODUCTION (3331/213) - THE DEVICE HISTORY RECORDS REVIEW CONCLUDED THAT THERE WERE NO NCMRS, REWORK, OR DEVIATIONS DOCUMENTED FOR THE REPORTED LOT/SERIAL NUMBER. BASED ON THE REVIEW RESULTS, IT WAS DETERMINED THAT THERE IS NO RELATION BETWEEN THE MANUFACTURING PROCESS AND THE REPORTED FAILURE. HISTORICAL DATA ANALYSIS (4109/213) - THE REVIEW OF THE HISTORICAL DATA WAS PERFORMED. TREND ANALYSIS (4110/213) - THE OVERALL COMPLAINT TREND DATA FOR THE PERIOD JUL-2019 THROUGH JUN-2021 WAS REVIEWED. COMMUNICATION/INTERVIEWS: (4111/213) COMMUNICATION/INTERVIEWS WERE PERFORMED TO OBTAIN ALL POSSIBLE INFORMATION. REFERENCE COMPLAINT #(B)(4).

Additional Manufacturer Narrative · 0

THE PRODUCT WAS RETURNED WITH THE MEMBRANE COMPLETELY UNFOLDED AND BLOOD ON THE EXTERIOR OF THE CATHETER. THE PRESSURE TUBING WAS ALSO RETURNED. NO BLOOD WAS VISIBLE INSIDE THE IAB CATHETER. ADDITIONALLY THE RETRACTION KIT WAS RETURNED UNUSED IN ITS PACKAGING. AN UNDERWATER LEAK TEST OF THE BALLOON, CATHETER, Y-FITTING, EXTRACORPOREAL AND PRESSURE TUBING WAS PERFORMED AND NO LEAKS WERE DETECTED. THE IAB WAS PLACED ON THE CS300 PUMP AND PUMPED FOR TWO HOURS WHICH REPRESENTS ONE COMPLETE AUTOFILL CYCLE. THE IAB PUMPED NORMALLY AND NO ALARM SOUNDED FROM THE PUMP. THE REPORTED EVENT CANNOT BE CONFIRMED BY THE EVALUATION. A NON-CONFORMING MATERIAL REPORT REVIEW WAS COMPLETED FOR THE REPORTED PRODUCT. NO NONCONFORMANCES WERE FOUND THAT ARE CONSIDERED TO BE RELATED TO THE EVENT. ANALYSIS OF PRODUCTION (3331/213) - THE DEVICE HISTORY RECORDS REVIEW CONCLUDED THAT THERE WERE NO NCMRS, REWORK, OR DEVIATIONS DOCUMENTED FOR THE REPORTED LOT/SERIAL NUMBER. BASED ON THE REVIEW RESULTS, IT WAS DETERMINED THAT THERE IS NO RELATION BETWEEN THE MANUFACTURING PROCESS AND THE REPORTED FAILURE. HISTORICAL DATA ANALYSIS (4109/213) - THE REVIEW OF THE HISTORICAL DATA WAS PERFORMED. TREND ANALYSIS (4110/213) - THE OVERALL COMPLAINT TREND DATA FOR THE PERIOD JUL-2019 THROUGH JUN-2021 WAS REVIEWED. COMMUNICATION/INTERVIEWS: (4111/213) COMMUNICATION/INTERVIEWS WERE PERFORMED TO OBTAIN ALL POSSIBLE INFORMATION. REFERENCE COMPLAINT #(B)(4).

Additional Manufacturer Narrative · 0

THE DEVICE HAS BEEN RETURNED TO THE FACTORY AND IS BEING EVALUATED. A SUPPLEMENTAL REPORT WILL BE SUBMITTED WHEN THE EVALUATION IS COMPLETED. COMPLAINT RECORD ID # (B)(4).

Description of Event or Problem · 0

N/A.

Description of Event or Problem · 0

N/A

Additional Manufacturer Narrative · 1

(B)(6). THE DEVICE HAS NOT BEEN RETURNED TO THE MANUFACTURER SO WE ARE UNABLE TO COMPLETE AN EVALUATION. IF PROVIDED WE WILL SEND A SUPPLEMENTAL REPORT WITH OUR ADDITIONAL FINDINGS. COMPLAINT RECORD ID # (B)(4).

Description of Event or Problem · 1

IT WAS REPORTED THAT AFTER INSERTING THE INTRA-AORTIC BALLOON (IAB), THE CONSOLE GENERATED A LEAK IN IAB CIRCUIT ALARM. THE CONSOLE WAS SWAPPED OUT WITH A DIFFERENT ONE, BUT THE ISSUE CONTINUED. THE IAB WAS THEN REPLACED WITH A NEW ONE AND THERAPY WAS CONTINUED SUCCESSFULLY. THERE WAS NO PATIENT HARM OR ADVERSE EVENT REPORTED.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1035175 YAMATO PLUS-R 7.5FR. 35CC IAB SYSTEM, BALLOON, INTRA-AORTIC AND CONTROL DSP DATASCOPE CORP. - FAIRFIELD 3000071396

Patients

Seq Age Sex Outcome Treatment
1 Unknown UNKNOWN.