FDA Adverse Event Death Summary report: N

SASUKE

MDR report key: 12132754 · Received July 7, 2021

Report

Report Number
3003775027-2021-00124
Event Type
Death
Date Received
July 7, 2021
Date of Event
May 19, 2021
Report Date
June 16, 2021
Manufacturer
ASAHI INTECC CO., LTD.
Product Code
DQY
UDI-DI
04547327120180
PMA / PMN Number
K182844
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
IT
Reporter Occupation
PHYSICIAN

Narratives

Additional Manufacturer Narrative · 1

MANUFACTURING SITE: ASAHI INTECC ((B)(6)) CO., LTD., PATHUM THANI, (B)(6), REGISTRATION NUMBER: (B)(4). DEVICE EVALUATION COULD NOT BE PERFORMED BECAUSE THE AFFECTED DEVICE WAS DISCARDED BY THE USER FACILITY. LOT HISTORY REVIEW REVEALED NO ANOMALY RELATING TO THE REPORTED EVENT. NO OTHER SIMILAR PRODUCT EXPERIENCE REPORT WAS RECEIVED FROM THIS LOT. FINDINGS OF PRODUCTION RECORDS DID NOT CONFIRM QUALITY ISSUES. BASED ON THE PROVIDED INFORMATION, IT WAS PRESUMED THAT THE TIP OR OUTER TUBE OF THE SASUKE WAS LIKELY CRUSHED DUE TO CALCIFIED ANATOMY, INCREASING RESISTANCE BETWEEN THE CATHETER LUMEN AND THE RG3 GUIDE WIRE. OR THE TIP OF THE SASUKE COULD BE TRAPPED IN THE LESION. EITHER WAY, IT WAS CONCLUDED THAT DIFFICULTY IN REMOVAL WAS NOT ATTRIBUTED TO PRODUCT QUALITY. ALTHOUGH THE GUIDE THETER HAD MOST LIKELY CAUSED THE REPORTED ASCENDING AORTA DISSECTION, POTENTIALITY COULD NOT BE COMPLETELY RULED OUT THAT FORCEFUL REMOVAL OF THE STUCK SASUKE MIGHT HAVE INDIRECTLY CONTRIBUTED TO THE DISSECTION. NO CAPA WILL BE TAKEN. INSTRUCTIONS FOR USE (IFU) STATES: [PRECAUTIONS]. THIS PRODUCT MUST BE MANIPULATED WHILE CHECKING THIS PRODUCT'S MOTION UNDER HIGH-RESOLUTION X-RAY FLUOROSCOPY. IN ADDITION, IF ANY RESISTANCE IS FELT DURING THE MANIPULATION OF THIS PRODUCT, INTERRUPT THE MANIPULATION, AND CHECK THE CAUSE UNDER HIGH-RESOLUTION X-RAY FLUOROSCOPY. [MALFUNCTIONS AND ADVERSE EFFECTS]. WITHDRAWAL DIFFICULTY, DISSECTION OF BLOOD VESSELS.

Description of Event or Problem · 1

IT WAS REPORTED THAT A PERCUTANEOUS CORONARY INTERVENTION (PCI) WAS PERFORMED TO TREAT A MODERATELY CALCIFIED, CHRONIC TOTAL OCCLUSION (CTO) IN THE RIGHT CORONARY ARTERY (RCA). AFTER EXTERNALIZATION WAS ACHIEVED WITH AN ASAHI RG3 GUIDE WIRE, A DES WAS IMPLANTED IN THE RCA. THE AN ASAHI SASUKE DOUBLE LUMEN CATHETER WAS ADVANCED FOR DISTAL ANTEGRADE WIRING TO COMPLETE STENTING OF THE POSTEROLATERAL ARTERY. AT THIS POINT, BOTH THE SASUKE AND THE RETROGRADE ASAHI CORSAIR PRO XS MICROCATHETER GOT STUCK ON THE RG3. AFTER MANY ATTEMPTS, A DESTROYED SASUKE WAS ABLE TO BE REMOVED FROM THE GUIDING CATHETER. BECAUSE THE CORSAIR PRO XS MICROCATHETER WAS STUCK ON THE RG3 AND UNABLE TO BE REMOVED, IT WAS REMOVED TOGETHER WITH THE RG3. THE CASE WAS VERY COMPLEX AND THIS PROCEDURE WAS A REATTEMPT AND WAS COMPLICATED BY ASCENDING AORTA DISSECTION AND PERFORATION OF THE COLLATERAL USED FOR THE RETROGRADE APPROACH. THE PATIENT SUFFERED CARDIAC ARREST, RESUSCITATION, PERICARDIAL TAMPONADE TREATED WITH DRAINAGE AND EXPIRED IN THE CCU 12 HOURS AFTER THE PCI. CORSAIR PRO XS: MFR REPORT # 3003775027-2021-00123. SASUKE: MFR REPORT # 3003775027-2021-00124. RG3: MFR REPORT # 3003775027-2021-00125.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1022933 SASUKE PERCUTANEOUS CATHETER DQY ASAHI INTECC CO., LTD. NA 210116F011 04547327120180

Patients

Seq Age Sex Outcome Treatment
1 Death| L| R