MEDTRONIC TRANSCATHETER VALVE
Report
- Report Number
- 2025587-2021-02079
- Event Type
- Injury
- Date Received
- July 2, 2021
- Date of Event
- April 30, 2021
- Report Date
- July 14, 2021
- Manufacturer
- MEDTRONIC HEART VALVES DIVISION
- Product Code
- NPT
- PMA / PMN Number
- P130021
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- SI
- Reporter Occupation
- PHYSICIAN
Narratives
ADDITIONAL INFORMATION RECEIVED FROM THE PHYSICIAN/AUTHOR STATED THAT A MEDTRONIC PRODUCT DID NOT CAUSE OR CONTRIBUTE TO THE OBSERVED DEATHS OR ADVERSE EVENTS. MEDTRONIC IS SUBMITTING THIS REPORT TO COMPLY WITH FDA REPORTING REGULATIONS UNDER 21 CFR PARTS 4 AND 803. THIS REPORT IS BASED UPON INFORMATION OBTAINED BY MEDTRONIC, WHICH THE COMPANY MAY NOT HAVE BEEN ABLE TO FULLY INVESTIGATE OR VERIFY PRIOR TO THE DATE THE REPORT WAS REQUIRED BY THE FDA. MEDTRONIC HAS MADE REASONABLE EFFORTS TO OBTAIN MORE COMPLETE INFORMATION AND HAS PROVIDED AS MUCH RELEVANT INFORMATION AS IS AVAILABLE TO THE COMPANY AS OF THE SUBMISSION DATE OF THIS REPORT. THIS REPORT DOES NOT CONSTITUTE AN ADMISSION OR A CONCLUSION BY FDA, MEDTRONIC, OR ITS EMPLOYEES THAT THE DEVICE, MEDTRONIC, OR ITS EMPLOYEE CAUSED OR CONTRIBUTED TO THE EVENT DESCRIBED IN THE REPORT. IN PARTICULAR, THIS REPORT DOES NOT CONSTITUTE AN ADMISSION BY ANYONE THAT THE PRODUCT DESCRIBED IN THIS REPORT HAS ANY ¿DEFECTS¿ OR HAS ¿MALFUNCTIONED¿. THESE WORDS ARE INCLUDED IN THE FDA 3500A FORM AND ARE FIXED ITEMS FOR SELECTION CREATED BY THE FDA TO CATEGORIZE THE TYPE OF EVENT SOLELY FOR THE PURPOSE OF REGULATORY REPORTING. MEDTRONIC OBJECTS TO THE USE OF THESE WORDS AND OTHERS LIKE THEM BECAUSE OF THE LACK OF DEFINITION AND THE CONNOTATIONS IMPLIED BY THESE TERMS. THIS STATEMENT SHOULD BE INCLUDED WITH ANY INFORMATION OR REPORT DISCLOSED TO THE PUBLIC UNDER THE FREEDOM OF INFORMATION ACT. ANY REQUIRED FIELDS THAT ARE UNPOPULATED ARE BLANK BECAUSE THE INFORMATION IS CURRENTLY UNKNOWN OR UNAVAILABLE. A GOOD FAITH EFFORT WILL BE MADE TO OBTAIN THE APPLICABLE INFORMATION RELEVANT TO THE REPORT. IF INFORMATION IS PROVIDED IN THE FUTURE, A SUPPLEMENTAL REPORT WILL BE ISSUED.
CITATION: PLESKOVIC A, ET AL. RESULTS OF TRANSCATHETER AORTIC VALVE IMPLANTATION (TAVI) IN THE INTERNATIONAL CENTRE FOR CARDIOVASCULAR DISEASES MC MEDICOR. ZDRAVVESTN. 30APR.2021 ;90(3-4):139-4. DOI 10.6016/ZDRAV VESTN.3150. EARLIEST DATE OF PUBLISH USED FOR DATE OF EVENT. NO UNIQUE DEVICE IDENTIFIER (SERIAL/LOT) NUMBERS WERE PROVIDED; WITHOUT THIS INFORMATION IT COULD NOT BE DETERMINED WHETHER THESE OBSERVATIONS HAVE BEEN PREVIOUSLY REPORTED. WITHOUT RETURN OF THE PRODUCT NO DEFINITIVE CONCLUSION CAN BE MADE REGARDING THE CLINICAL OBSERVATIONS. IF INFORMATION IS PROVIDED IN THE FUTURE, A SUPPLEMENTAL REPORT WILL BE ISSUED.
MEDTRONIC RECEIVED INFORMATION VIA LITERATURE REGARDING A RETROSPECTIVE STUDY OF THE RESULTS OF TRANSCATHETER AORTIC VALVE (TAV) IMPLANTATIONS. ALL DATA WERE COLLECTED FROM A SINGLE CENTER BETWEEN 2016 AND 2020. THE STUDY POPULATION INCLUDED 109 PATIENTS (PREDOMINANTLY MALE, MEAN AGE 81 YEARS), 94 OF WHOM WERE IMPLANTED WITH MEDTRONIC EVOLUTR OR EVOLUTPRO TAV. SERIAL NUMBERS WERE NOT PROVIDED. AMONG ALL PATIENTS, NO DEATHS WERE ASSOCIATED WITH A MEDTRONIC DEVICE. AMONG ALL PATIENTS, ADVERSE EVENTS INCLUDED: MODERATE AORTIC INSUFFICIENCY/REGURGITATION, SEVERE PARAVALVULAR LEAK (PVL), PERMANENT PACEMAKER IMPLANTATION, LEFT VENTRICLE PERFORATION TREATED WITH CARDIAC SURGERY, TRANSIENT ISCHEMIC ATTACK (TIA), PSEUDOANEURYSM, STENT PLACEMENT. BASED ON THE AVAILABLE INFORMATION A MEDTRONIC PRODUCT MAY HAVE BEEN ASSOCIATED WITH THE ADVERSE EVENTS. NO ADDITIONAL ADVERSE PATIENT EFFECTS OR PRODUCT PERFORMANCE ISSUES WERE REPORTED.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1005834 | MEDTRONIC TRANSCATHETER VALVE | AORTIC VALVE, PROSTHESIS, PERCUTANEOUSLY DELIV | NPT | MEDTRONIC HEART VALVES DIVISION | MDT-TRANS VALVE |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 81 YR | Required Intervention |