FDA Adverse Event Death Summary report: N

11.F X 15CM DUO-FLOW IJ CATHETER

MDR report key: 12087683 · Received June 29, 2021

Report

Report Number
2518902-2021-00032
Event Type
Death
Date Received
June 29, 2021
Date of Event
June 3, 2021
Report Date
July 23, 2021
Manufacturer
MEDICAL COMPONENTS, INC.
Product Code
MPB
UDI-DI
00884908059144
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
SP
Reporter Occupation
003

Narratives

Additional Manufacturer Narrative · 0

THE DEVICE INVOLVED IN THE INCIDENT WAS UNAVAILABLE FOR EVALUATION. THE FACILITY REPORTING THE INCIDENT WAS UNABLE TO PROVIDE THE LOT NUMBER OF THE DEVICE. A REVIEW OF THE MANUFACTURING RECORDS WAS NOT POSSIBLE. THE REPORT INDICATED THAT AFTER REMOVING THE CATHETER THE PATIENT PRESENTED RAPID CLINICAL DETERIORATION AND CARDIAC ARREST. AN EMERGENT STERNOTOMY REVEALED THE EXISTENCE OF A LARGE HEMATOMA IN THE RIGHT HEMOTHORAX (RIGHT OF THE HEART AND MEDIASTINUM). THE CATHETER HAD BEEN INSERTED INTO THE RIGHT INTERNAL JUGULAR VEIN. LITERATURE STATES THAT HEMATOMA AND VENOUS PUNCTURE ARE COMMON COMPLICATIONS THAT CAN OCCUR DURING CATHETERIZATION. THE PATIENT WAS POST AORTIC VALVE REPLACEMENT. THE USE OF ANTICOAGULANTS ARE COMMON POST VALVE REPLACEMENT. THIS MAY HAVE CONTRIBUTED TO BLEEDING AND THE FORMATION OF THE HEMATOMA. THE HOSPITAL DID NOT ESTABLISH A DIRECT LINK BETWEEN THE DEVICE AND THE EVENT. INSTRUCTIONS FOR USE INCLUDE THE FOLLOWING POTENTIAL COMPLICATIONS: HEMORRHAGE, INFERIOR VENA CAVA PUNCTURE, LACERATION OF VESSEL, PERFORATION OF VESSEL, SUPERIOR VENA CAVA PUNCTURE.

Additional Manufacturer Narrative · 1

DEVICE WAS USED FOR TREATMENT, NOT DIAGNOSIS. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE.

Description of Event or Problem · 1

PATIENT HAD AORTIC VALVE REPLACEMENT AND CORONARY BYPASS SURGERY ON (B)(6) 2021. POST OPERATIVELY IN THE CRITICAL CARE UNIT, HE PRESENTED WITH DETERIORATION OF KIDNEY FUNCTION. ON (B)(6) 2021 A PERCUTANEOUS DIALYSIS CATHETER WAS INSERTED THROUGH ULTRASOUND-GUIDED RIGHT INTERNAL JUGULAR VEIN, TO PERFORM DIALYSIS. AFTER INSERTION, PATIENT SITS DOWN. HEMODYNAMICALLY AND RESPIRATORY STABLE. WHEN STARTING DIALYSIS, AIR ASPIRATION WAS OBSERVED THROUGH ONE OF THE LIGHTS. ON CHEST RADIOGRAPHY, THE CATHETER APPEARS TO BE NORMALIZED, SO IT WAS DECIDED TO REMOVE IT AND INSERT A NEW ONE. AFTER REMOVING THE CATHETER, THE PATIENT PRESENTED RAPID CLINICAL DETERIORATION, WITH CARDIAC ARREST. RESUSCITATION MANEUVERS AND EMERGENT STERNOTOMY REVEALED THE EXISTENCE OF A LARGE HEMATOMA IN THE RIGHT HEMOTHORAX. REGULATED SURGICAL REVISION WAS PERFORMED, NO VASCULAR LESION WAS OBSERVED, NOR NEW BLEEDING. UNFAVORABLE SUBSEQUENT EVOLUTION, WITH CEREBRAL HYPOXIA, AND DEATH TWO DAYS LATER.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
979066 11.F X 15CM DUO-FLOW IJ CATHETER DUO-FLOW IJ SHORT TERM HEMODIALYSIS CATHETER MPB MEDICAL COMPONENTS, INC. XTP116IJS 00884908059144

Patients

Seq Age Sex Outcome Treatment
1 74 YR Death