PLATE SCHAEDLER/SCHAED KV 5% SB 120
Report
- Report Number
- 9680577-2021-00023
- Event Type
- Malfunction
- Date Received
- June 29, 2021
- Date of Event
- June 1, 2021
- Report Date
- December 9, 2021
- Manufacturer
- BECTON DICKINSON GMBH
- Product Code
- JSJ
- PMA / PMN Number
- K760460
- Removal / Correction Number
- IDS-21-4201
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- GM
- Reporter Occupation
- OTHER HEALTH CARE PROFESSIONAL
- Health Professional
- Yes
Narratives
A DEVICE EVALUATION AND/OR DEVICE HISTORY REVIEW IS ANTICIPATED, BUT IS NOT COMPLETE. UPON COMPLETION, A SUPPLEMENTAL REPORT WILL BE FILED.
THE FOLLOWING FIELDS WERE UPDATED DUE TO ADDITIONAL INFORMATION: H.7. REMEDIAL ACTION REQUIRED: RECALL H.9. REMEDIAL ACTION #: IDS-21-4201 H.6. INVESTIGATION: THIS STATEMENT IS TO SUMMARIZE FINDINGS ON THE RECENT COMPLAINT AGAINST PLATE SCHAEDLER AGAR / SCHAEDLER KV AGAR WITH 5% SHEEP BLOOD (BIPLATE) CATALOG NUMBER 257589, LOT NUMBER 1104468. EVENT DESCRIPTION: IT WAS REPORTED THAT THE MEDIUM WAS CONTAMINATED. REPORTEDLY, A THIRD OF THE BOX WAS AFFECTED. COMPLAINT HISTORY REVIEW: THE COMPLAINT TRENDS WERE REVIEWED FOR A PERIOD COVERING 12 MONTHS. FOR THIS PRODUCT, SEVERAL COMPLAINTS WERE REPORTED FOR CONTAMINATION ISSUES. THEREFORE, A TREND WAS IDENTIFIED, AND FURTHER INVESTIGATION WAS PERFORMED. BATCH HISTORY RECORD (BHR) REVIEW: THE BATCH HISTORY REVIEW WAS PERFORMED. AS PART OF THE INVESTIGATION, THE INGREDIENTS OF THIS MEDIUM WERE REVIEWED. DURING THIS REVIEW, NO DEVIATION WAS DETECTED. SAMPLE ANALYSIS: PICTURE SAMPLE WAS NOT PROVIDED FOR EVALUATION. RETAIN SAMPLES WERE REVIEWED FOR THIS LOT. DURING THIS REVIEW, CONTAMINATION COULD BE DETECTED. EVALUATION RESULTS: AT THIS STAGE OF OUR INVESTIGATION, WE HAVE EXCLUDED ANY SYSTEMIC FAILURE IN OUR MANUFACTURING PROCESS. A MATERIAL REVIEW BOARD (MRB) WAS CONDUCTED WHICH LED TO A SITUATION ANALYSIS (SA) WHICH EVENTUALLY RESULTED IN A RECALL. THE PERFORMED INVESTIGATION SHOWED THAT THE ORIGIN OF THE CONTAMINATION WAS ASSOCIATED WITH AN ANAEROBIC MICROORGANISM GROWING AT LOWER TEMPERATURES (<22°C). THIS MICROORGANISM WAS DETECTED FOR THE FIRST TIME AT THE PRODUCTION SITE. THEREFORE, AND AS NO CONTAMINATION COMPLAINTS WERE RECEIVED IN CONJUNCTION WITH THE RESPECTIVE PRODUCT WITHIN THE PAST YEAR THIS EVENT WAS CONCLUDED TO BE A SINGLE INCIDENT. HOWEVER, REGARDING THE REPORTED CONTAMINATION, PLEASE NOTE THAT THIS PRODUCT DOES NOT HAVE AN SAL (STERILITY ASSURANCE LEVEL) CLAIM. IT IS FILLED ASEPTICALLY, THEREFORE AN OCCURRENCE OF A CONTAMINATION EVENT CANNOT BE ENTIRELY RULED OUT. INVESTIGATION CONCLUSION: BASED ON THE EVALUATION OF THE REPORT THE COMPLAINT IS CONFIRMED. AN MRB WAS INITIATED AND A SA WAS PERFORMED FOR CONTAMINATION ISSUE, WHICH LED TO A RECALL. WE WOULD SUGGEST TO SET ASIDE, AND NOT USE, ANY PREPARED PLATED MEDIA THAT DOES NOT MEET THE APPEARANCE SPECIFICATION AS IT IS DESCRIBED ON THE BD CERTIFICATE OF ANALYSIS. THIS IS CONSISTENT WITH INDUSTRY RECOMMENDATIONS FOR INSPECTION OF CULTURE MEDIA PRIOR TO USE (E.G. ¿GOOD PRACTICES FOR PHARMACEUTICAL MICROBIOLOGY LABORATORIES¿, WHO TECHNICAL REPORT SERIES, NO. 961, 2011, ANNEX 2; CHAPTER <1117> ¿MICROBIOLOGY BEST LABORATORY PRACTICES¿ THE UNITED STATES PHARMACOPEIA; AND THE DIFCO & BBL MANUAL).
IT WAS REPORTED THAT WHILE USING 40 PLATES SCHAEDLER/SCHAED KV 5% SB 120 CONTAMINATION WAS OBSERVED BY THE LABORATORY PERSONNEL. THERE WAS NO INDICATION THAT RESULTS WERE REPORTED OUT AND THERE WAS NO REPORT OF PATIENT IMPACT. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: "SCHAEDLER SIDE CONTAMINATED. "
IT WAS REPORTED THAT WHILE USING 40 PLATES SCHAEDLER/SCHAED KV 5% SB 120 CONTAMINATION WAS OBSERVED BY THE LABORATORY PERSONNEL. THERE WAS NO INDICATION THAT RESULTS WERE REPORTED OUT AND THERE WAS NO REPORT OF PATIENT IMPACT. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: "SCHAEDLER SIDE CONTAMINATED."
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 978976 | PLATE SCHAEDLER/SCHAED KV 5% SB 120 | CULTURE MEDIA, SELECTIVE AND NON-DIFFERENTIAL | JSJ | BECTON DICKINSON GMBH | 1104468 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Unknown |