POWERBANK ENTERPRISE EDITION 1.0
Report
- Report Number
- 3006611234-2008-00001
- Event Type
- Other
- Date Received
- October 17, 2008
- Date of Event
- July 10, 2008
- Report Date
- July 10, 2008
- Manufacturer
- ECLIPSYS INDIA PVT. LTD.
- Product Code
- MMH
- PMA / PMN Number
- BK060014
- Report Source
- Manufacturer report
- Reporter Location
- CA
- Reporter Occupation
- OTHER
Narratives
BACKGROUND: WHEN RECEIVED INTO POWERBANK ENTERPRISE (B) (4), SOME UNITS ARE FLAGGED AS UNCHECKED SO THAT BLOOD GROUP AND OTHER CRITERIA MAY BE VERIFIED BEFORE MAKING THE UNITS AVAILABLE FOR ASSIGNMENT. THERE ARE TWO WAYS TO CHANGE THE UNCHECKED UNITS TO AVAILABLE UNITS: MANUAL - FROM THE UNIT DETAILS WINDOW, THE OPERATOR ACCEPTS THE UNCHECKED UNIT, MAKING IT AVAILABLE; AUTOMATIC - A BACKGROUND PROCESS RUNS AT FIXED INTERVALS TO CHECK ALL UNCHECKED UNITS. RESULTS ARE THEN COMPARED WITH PREVIOUS RESULTS. IF RESULTS ARE UN-POSTED OR DON'T MATCH PREVIOUS RESULTS, THE UNIT IS NOT MADE AVAILABLE. IF ALL CRITERIA ARE MET, THE SYSTEM MAKES THE UNIT AVAILABLE. INVESTIGATION SUMMARY: A USER REPORTED THAT A UNIT WAS FLAGGED AVAILABLE, BUT RESULTS WERE NOT POSTED. THE DEVICE IS SOFTWARE AND CANNOT BE PHYSICALLY RETURNED. WE USED OUR COPY OF THE SOFTWARE FOR TESTING. WE WERE UNABLE TO RECREATE THE INCIDENT AND FOUND NO EVIDENCE OF SOFTWARE ERROR. HOWEVER, WE HAVE ADDED AN UPGRADE TO ENHANCE CONTROL. WE HAVE ADDED AN ADD'L LAYER OF CODE THAT WILL PERFORM A SECOND CHECK THAT RESULTS ARE ON FILE AND MEET CRITERIA PRIOR TO CHANGING THE STATUS TO AVAILABLE. THIS CHECK WILL OVERRIDE THE AVAILABILITY OF THE SELECTED UNIT IF THE RESULTS DO NOT MEET CRITERIA OR IF THE RESULTS FILE IS UNAVAILABLE. THIS CHANGE WILL BE MADE AVAILABLE TO ALL CURRENT USERS AND HAS BEEN INCORPORATED INTO ALL NEW DISTRIBUTIONS OF THE SOFTWARE.
REPORTED INCIDENT: A USER REPORTED THAT THE STATUS OF A BLOOD UNIT, WHOSE BLOOD GROUP WAS REQUIRED TO BE CONFIRMED BEFORE BEING RESERVED TO A PATIENT, WAS ENTERED AS UNCHECKED. THE STATUS OF THIS UNIT SUBSEQUENTLY APPEARED AS AVAILABLE FOR RESERVATION, EVEN THOUGH THE BLOOD GROUP CHECK RESULT WAS NOT POSTED.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1 | POWERBANK ENTERPRISE EDITION 1.0 | MMH | ECLIPSYS INDIA PVT. LTD. |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 |