EMPOWR 3D KNEE
Report
- Report Number
- 1644408-2021-00583
- Event Type
- Injury
- Date Received
- June 15, 2021
- Date of Event
- May 24, 2021
- Report Date
- June 30, 2021
- Manufacturer
- ENCORE MEDICAL LP
- Product Code
- JWH
- UDI-DI
- 00888912167031
- PMA / PMN Number
- K143242
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- VA, US
- Reporter Occupation
- 003
Narratives
THE REASON FOR THIS REVISION SURGERY WAS REPORTED AS LOOSENING. THE PREVIOUS SURGERY AND THE SURGERY DETAILED IN THIS EVENT OCCURRED 1 YEAR AND 2 MONTHS APART. THE HEALTHCARE PROFESSIONAL INDICATED THERE WAS NO DELAY IN SURGERY AND ANOTHER SUITABLE DEVICE WAS AVAILABLE FOR USE. THE REVISION SURGERY WAS COMPLETED AS INTENDED. THE DEVICE WAS DISPOSED OF AT HOSPITAL AND NOT MADE AVAILABLE TO DJO SURGICAL FOR EXAMINATION. A REVIEW OF THE DEVICE HISTORY RECORD (DHR) SHOWS THAT THE REPORTED COMPONENT USED IN THE PREVIOUS SURGERY, WHEN RELEASED FOR USE, MET DESIGN AND MANUFACTURING REQUIREMENTS. THERE WAS NO NON-CONFORMING MATERIAL REPORT (NCMR) ASSOCIATED WITH THE PRODUCT THAT MAY HAVE CONTRIBUTED TO THE REPORTED EVENT. THE DEVICE WAS VERIFIED TO HAVE GONE THROUGH AN ACCEPTABLE STERILIZATION PROCESS AND WAS WITHIN ITS EXPIRATION DATE AT THE TIME OF THE PREVIOUS SURGERY. CUSTOMER COMPLAINT HISTORY OF THE REPORTED DEVICE SHOWED NO PRESENT TRENDS OR ON-GOING ISSUES THAT ARE NEEDING A REVIEW. THE ROOT CAUSE OF THIS COMPLAINT WAS A REVISION SURGERY DUE TO LOOSENING. THERE WERE NO FINDINGS DURING THIS EVALUATION THAT INDICATE THE REPORTED DEVICE WAS DEFECTIVE. NO INFORMATION WAS SUBMITTED WITH THE COMPLAINT REGARDING PRE-EXISTING CONDITIONS OF THE PATIENT OR ANY ACTIVITIES THE PATIENT WAS INVOLVED IN THAT MAY HAVE CONTRIBUTED TO THE EVENT. THERE ARE MULTIPLE FACTORS THAT MAY ALSO CONTRIBUTE TO AN EVENT THAT ARE OUTSIDE THE CONTROL OF DJO SURGICAL SUCH AS POOR BONE DENSITY, PATIENT BONE DETERIORATION, INADEQUATE SOFT TISSUE SUPPORT OR PATIENT ACTIVITIES. THERE ARE NO INDICATIONS OF A PRODUCT OR PROCESS ISSUE AFFECTING IMPLANT SAFETY OR EFFECTIVENESS. ADDITIONAL REPORTING ON THIS EVENT WILL BE PROVIDED AS A SUPPLEMENTAL REPORT TO THIS DOCUMENT IF IT BECOMES AVAILABLE.
ADDITIONAL REPORTING ON THIS EVENT WILL BE PROVIDED AS A SUPPLEMENTAL REPORT TO THIS DOCUMENT AS SOON AS IT BECOMES AVAILABLE.
REVISION SURGERY - POLY SWAP FOR LOOSENING OR LAXITY. NO KNOWN INFECTION OR TRAUMA.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 893806 | EMPOWR 3D KNEE | EMPOWR 3D KNEETM INS, 6L 14MM, VE | JWH | ENCORE MEDICAL LP | 341-14-706 | 130T1052 | 00888912167031 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 64 YR | Required Intervention |