FDA Adverse Event Death Summary report: N

ONX MITRAL CONFORM 25/33

MDR report key: 11991289 · Received June 14, 2021

Report

Report Number
1649833-2021-00021
Event Type
Death
Date Received
June 14, 2021
Report Date
August 10, 2021
Manufacturer
ON-X LIFE TECHNOLOGIES, INC.
Product Code
LWQ
PMA / PMN Number
P000037
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
FL, US
Reporter Occupation
OTHER

Narratives

Description of Event or Problem · 0

ACCORDING TO THE INITIAL REPORT RECEIVED VIA EMAIL ON 07-JUNE-2021 THE PUBLICATION BY HANNA N, CARMONA A, CRESPO H, CUBEDDU RJ. TITLED MECHANICAL TRICUSPID BALLOON ¿VALVULOPLASTY¿ IN A PROHIBITIVE RISK PATIENT WITH CARDIOGENIC SHOCK: A CASE REPORT. EUROPEAN HEART JOURNAL ¿ CASE REPORTS. 2020;4:1-4. REPORTS A PATIENT WITH MULTIPLE COMORBIDITIES, INCLUDING ENDOCARDITIS, PREVIOUS MECHANICAL AVR, AND TRICUSPID REPAIR. ON-X IMPLANTATION IN THE TRICUSPID POSITION HAD AN IMMOBILE LEAFLET THAT WAS SUCCESSFULLY RELEASED BY BALLOON ¿VALVULOPLASTY.¿ THE REASON FOR THE IMMOBILE ON-X LEAFLET WAS UNKNOWN, BUT PATIENT CONDITION RULED OUT RE-OPERATION. AFTER UNSUCCESSFUL ATTEMPTS TO MECHANICALLY FORCE THE LEAFLET OPEN, BALLOON ¿VALVULOPLASTY¿ (INFLATED GRADUALLY TO 8 ATM) RELEASED THE STUCK LEAFLET. ON-X VALVE IN THE TRICUSPID POSITION APPEARS TO HAVE HAD STRUCTURAL DYSFUNCTION (IMMOBILE LEAFLET, NO EVIDENCE OF LEAFLET THROMBOSIS) THAT WAS RELEASED BY BALLOON ¿VALVULOPLASTY,¿ BUT PATIENT DIED 5 DAYS POSTOP OF MULTISYSTEM ORGAN FAILURE. CASE STUDY OF ON-X VALVE IN THE TRICUSPID POSITION (AN OFF LABEL APPLICATION). ATTEMPTS TO OBTAIN ADDITIONAL INFORMATION HAVE GONE UNMET.

Description of Event or Problem · 1

ACCORDING TO THE INITIAL REPORT RECEIVED VIA EMAIL ON 07-JUNE-2021 THE PUBLICATION BY HANNA N, CARMONA A, CRESPO H, CUBEDDU RJ. TITLED MECHANICAL TRICUSPID BALLOON ¿VALVULOPLASTY¿ IN A PROHIBITIVE RISK PATIENT WITH CARDIOGENIC SHOCK: A CASE REPORT. EUROPEAN HEART JOURNAL ¿ CASE REPORTS. 2020;4:1-4. REPORTS A PATIENT WITH MULTIPLE COMORBIDITIES, INCLUDING ENDOCARDITIS, PREVIOUS MECHANICAL AVR, AND TRICUSPID REPAIR. ON-X IMPLANTATION IN THE TRICUSPID POSITION HAD AN IMMOBILE LEAFLET THAT WAS SUCCESSFULLY RELEASED BY BALLOON ¿VALVULOPLASTY.¿ THE REASON FOR THE IMMOBILE ON-X LEAFLET WAS UNKNOWN, BUT PATIENT CONDITION RULED OUT RE-OPERATION. AFTER UNSUCCESSFUL ATTEMPTS TO MECHANICALLY FORCE THE LEAFLET OPEN, BALLOON ¿VALVULOPLASTY¿ (INFLATED GRADUALLY TO 8 ATM) RELEASED THE STUCK LEAFLET. ON-X VALVE IN THE TRICUSPID POSITION APPEARS TO HAVE HAD STRUCTURAL DYSFUNCTION (IMMOBILE LEAFLET, NO EVIDENCE OF LEAFLET THROMBOSIS) THAT WAS RELEASED BY BALLOON ¿VALVULOPLASTY,¿ BUT PATIENT DIED 5 DAYS POSTOP OF MULTISYSTEM ORGAN FAILURE. CASE STUDY OF ON-X VALVE IN THE TRICUSPID POSITION (AN OFF LABEL APPLICATION).

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
889484 ONX MITRAL CONFORM 25/33 HEART-VALVE MECHANICAL LWQ ON-X LIFE TECHNOLOGIES, INC. ONXMC-25/33

Patients

Seq Age Sex Outcome Treatment
1 67 YR Death| L