SOLUS BILIARY STENT AND INTRODUCER SET
Report
- Report Number
- 3001845648-2021-00472
- Event Type
- Injury
- Date Received
- June 11, 2021
- Date of Event
- May 15, 2016
- Report Date
- January 21, 2022
- Manufacturer
- COOK IRELAND LTD
- Product Code
- FGE
- PMA / PMN Number
- K851962
- Adverse Event
- Yes
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Occupation
- PHYSICIAN
- Health Professional
- Yes
Narratives
DEVICE EVALUATION: 10 X UNKNOWN SOLUS DOUBLE PIGTAIL BILIARY STENT DEVICE OF UNKNOWN RPN AND OF UNKNOWN LOT NUMBER INVOLVED IN THIS COMPLAINT WAS NOT AVAILABLE FOR EVALUATION. WITH THE INFORMATION PROVIDED, A DOCUMENT-BASED INVESTIGATION WAS CONDUCTED. THIS FILE WAS CREATED FROM THE JOURNAL ARTICLE, ¿A TWO-CENTER COMPARATIVE STUDY OF PLASTIC AND LUMEN-APPOSING LARGE DIAMETER SELF-EXPANDABLE METALLIC STENTS IN ENDOSCOPIC ULTRASOUND-GUIDED DRAINAGE OF PANCREATIC FLUID COLLECTIONS¿ PR¿S CREATED FROM LITERATURE PAPER : (B)(6) (MDR REF: 3001845648-2021-00472) - ANG TL 2016 ¿ 10 CASES STENT MIGRATION - PS GROUP (SINGAPORE); (B)(6) (MDR REF: 3001845648-2021-00473)- ANG TL 2016 - 10 CASES RATE OF INADEQUATE DRAINAGE DESPITE CORRECT STENT (NO MIGRATION) - PS GROUP (SINGAPORE); PR (B)(6) (MDR REF: 3001845648-2021-00474) - ANG TL 2016 ¿ 5 ADVERSE EVENTS IN PS GROUP (SINGAPORE); (B)(6) - ANG TL 2016 ¿ 10 CASES STENT MIGRATION - PS GROUP (THAILAND); PR (B)(6) - ANG TL 2016 - 10 CASES RATE OF INADEQUATE DRAINAGE DESPITE CORRECT STENT (NO MIGRATION) - PS GROUP (THAILAND); (B)(6) - ANG TL 2016 ¿ 5 ADVERSE EVENTS IN PS GROUP (THAILAND). DOCUMENT REVIEW INCLUDING IFU REVIEW: PRIOR TO DISTRIBUTION ALL ¿SOLUS DOUBLE PIGTAIL STENT¿ DEVICES ARE SUBJECTED TO A VISUAL INSPECTION AND FUNCTIONAL CHECKS TO ENSURE DEVICE INTEGRITY. THESE INSPECTIONS AND FUNCTIONAL CHECKS ARE OUTLINED IN INTERNAL PROCEDURES IN PLACE AT CIRL. A REVIEW OF THE MANUFACTURING RECORDS FOR THE SOLUS DOUBLE PIGTAIL STENT DEVICES COULD NOT BE COMPLETE AS THE LOT NUMBERS ARE UNKNOWN. AS PER INSTRUCTIONS FOR USE, IFU0100-1, INTENDED USE SECTION: ¿THIS DEVICE IS USED TO DRAIN OBSTRUCTED BILIARY DUCTS.¿ NOTES SECTION: ¿DO NOT USE THIS DEVICE FOR ANY PURPOSE OTHER THAN STATED INTENDED USE.¿ ALSO, AS PER THE IFU POTENTIAL COMPLICATIONS SECTION: "POTENTIAL COMPLICATIONS ASSOCIATED WITH ERCP INCLUDE, BUT ARE NOT LIMITED TO: PANCREATITIS, CHOLANGITIS, PERFORATION, HAEMORRHAGE, INFECTION, SEPSIS, ALLERGIC REACTION TO CONTRAST OR MEDICATION, HYPOTENSION, RESPIRATORY DEPRESSION OR ARREST, CARDIAC ARRHYTHMIA OR ARREST. ADDITIONAL COMPLICATIONS ASSOCIATED WITH BILIARY STENT PLACEMENT INCLUDE, BUT ARE NOT LIMITED TO: TRAUMA TO THE BILIARY TRACT OR DUODENUM, OBSTRUCTION OF THE PANCREATIC DUCT, STENT MIGRATION". STENT MIGRATION IS A KNOWN COMPLICATION ASSOCIATED WITH THE DEVICE. HOWEVER, IT IS CONFIRMED THAT DEVICE WAS USED OFF LABEL FOR TRANSMURAL DRAINAGE FOR PANCREATIC FLUID COLLECTIONS (PFCS) AND WALLED-OFF-NECROSIS(WON) EUS-GUIDED DRAINAGE OF PANCREATIC FLUID COLLECTIONS IS CONSIDERED OFF-LABEL USE ROOT CAUSE REVIEW: A POSSIBLE ROOT CAUSE COULD BE ATTRIBUTED TO OFF-LABEL USE OF THE DEVICE, WHEN THE DEVICE IS OUTSIDE ITS STATED INTENDED USE, IT MAY LEAD TO OUTCOMES THAT WERE NEVER INTENDED TO HAPPEN AND WERE NEVER STUDIED. SUMMARY: COMPLAINT IS CONFIRMED BASED ON CUSTOMER TESTIMONY. DUE TO THE OCCURRENCE, REPEAT ENDOSCOPIC DRAINAGE PROCEDURES WERE PERFORMED. COMPLAINTS OF THIS NATURE WILL CONTINUE TO BE MONITORED FOR POTENTIAL EMERGING TRENDS.
SUPPLEMENTAL REPORT IS BEING SUBMITTED DUE TO THE COMPLETION OF THE INVESTIGATION.
INVESTIGATION IS STILL PENDING. A FOLLOW UP MDR WILL BE SUBMITTED TO INCLUDE THE INVESTIGATION CONCLUSIONS.
ANG TL AT AL 2016 ¿ ¿A TWO-CENTRE COMPARATIVE STUDY OF PLASTIC AND LUMEN-APPOSING LARGE DIAMETER SELF-EXPANDABLE METALLIC STENTS IN ENDOSCOPIC ULTRASOUND-GUIDED DRAINAGE OF PANCREATIC FLUID COLLECTIONS¿ AS PER TABLE 3 ¿ THIS FILE WILL CAPTURE 10 CASES STENT MIGRATION IN PS GROUP, 3 OF WHICH REQUIRED REPEAT STENTING. PLEASE NOTE, USE OF DOUBLE PIGTAIL SOLUS BILIARY STENT FOR PANCREATIC INDICATION IS CONSIDERED OFF LABEL USE. THIS PAPER TOOK PLACED IN THE (B)(6) AND (B)(6); THEREFORE, FILES HAVE BEEN CREATED TO COVER BOTH LOCATIONS. THIS FILE IS CAPTURING (B)(6).
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 883703 | SOLUS BILIARY STENT AND INTRODUCER SET | FGE CATHETER, BILIARY, DIAGNOSTIC | FGE | COOK IRELAND LTD |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 56 YR | Male | Required Intervention |