FDA Adverse Event Malfunction Summary report: N

SYRINGE 10ML LL S/C 200

MDR report key: 11972008 · Received June 9, 2021

Report

Report Number
1213809-2021-00416
Event Type
Malfunction
Date Received
June 9, 2021
Date of Event
May 14, 2021
Report Date
July 2, 2021
Manufacturer
BECTON DICKINSON MEDICAL SYSTEMS
Product Code
FMF
UDI-DI
00382903029952
PMA / PMN Number
K980987
Product Problem
Yes
Report Source
Manufacturer report
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 0

H6: INVESTIGATION SUMMARY: THREE PHOTOS WERE RECEIVED AND EVALUATED. A 400 (200X2) COUNT CASE LABEL, CONFIRMED TO BE FROM BATCH 8213944 (MATERIAL 302995), WAS OBSERVED IN THE PHOTOS. ONE PHOTO SHOWED TWO INDIVIDUAL PACKAGES SIDE BY SIDE. ONE PACKAGE HAD BATCH 8213944 AND EXPIRATION DATE PRINTED ON THE TOP WEB; ONE PACKAGE HAD NO EXPIRATION AND NO BATCH # PRINTED ON ITS TOP WEB. PER APPLICABLE GRAPHICS DRAWING, VARIABLE PRINT INFORMATION MUST BE PRINTED ON THE TOP WEB. CURRENT PRODUCTION WAS EVALUATED, LINE TECHNICIANS AND PROCESS ENGINEER WERE INTERVIEWED AS PART OF THE INVESTIGATION. THE BLISTERPACK PRINTER FUNCTIONED AS EXPECTED. VARIABLE PRINT DETECTION SYSTEM IS CURRENTLY SET UP FOR SOME OF THE CAVITIES AND INTERRUPTS PROCESS PER REJECTION CRITERIA WHEN PACKAGES WITH IMPROPER UNIQUE DEVICE IDENTIFIER PRINT ARE DETECTED. POTENTIAL ROOT CAUSE FOR THE MISSING VARIABLE PRINT ON PACKAGE DEFECT IS ASSOCIATED WITH THE PACKAGING PROCESS: (1) IT IS POSSIBLE DURING ONE OF THE TOP WEB CHANGES THE TOP WEB PRINTER WAS NOT PUT IN ITS WORKING CONDITION PRIOR TO RESUMING THE PRODUCTION. (2) INADEQUATE VARIABLE PRINT VERIFICATION ON PACKAGES. CURRENT SYSTEM DOES NOT CHECK EVERY CAVITY FOR PRESENCE OF VARIABLE PRINT. SINCE THE PRODUCTION OF BATCH 8213944 (MATERIAL 302995), VARIABLE PRINT WAS UPDATED TO INCLUDE 2D BARCODE PER REGULATORY REQUIREMENTS. (1) THE CURRENT PACKAGING PRINT VERIFICATION SYSTEM WILL BE UPGRADED TO INCLUDE SENSORS FOR ALL PACKAGE CAVITIES. THE 2D BARCODE WILL BE SCANNED ON EVERY PACKAGE AND PRODUCT WILL BE AUTO-REJECTED IF NO BARCODE IS DETECTED OR IT IS ILLEGIBLE. DUE DATE: NOV 2021. A DEVICE HISTORY RECORD REVIEW SHOWED NO REJECTED INSPECTIONS OR QUALITY ISSUES DURING THE PRODUCTION OF THE PROVIDED LOT NUMBER THAT COULD HAVE CONTRIBUTED TO THE REPORTED DEFECT. COMPLAINTS RECEIVED FOR THIS DEVICE AND REPORTED CONDITION WILL CONTINUE TO BE TRACKED AND TRENDED. INFORMATION WILL BE CAPTURED ON TREND REPORTS AND MONITORED MONTHLY. OUR BUSINESS TEAM REGULARLY REVIEWS THE COLLECTED DATA FOR IDENTIFICATION OF EMERGING TRENDS.

Description of Event or Problem · 0

IT WAS REPORTED THAT SYRINGE 10ML LL S/C 200 WAS MISSING THE EXPIRATION DATE. THIS OCCURRED ON 2800 OCCASIONS. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: IT WAS REPORTED THAT 14 CASES DO NOT HAVE A LOT OR AN EXPIRATION DATE PRINTED ON THEM.

Additional Manufacturer Narrative · 1

DATE OF EVENT: UNKNOWN. THE DATE RECEIVED BY MANUFACTURER HAS BEEN USED FOR THIS FIELD. A DEVICE EVALUATION AND/OR DEVICE HISTORY REVIEW IS ANTICIPATED, BUT IS NOT COMPLETE. UPON COMPLETION, A SUPPLEMENTAL REPORT WILL BE FILED.

Description of Event or Problem · 1

IT WAS REPORTED THAT SYRINGE 10ML LL S/C 200 WAS MISSING THE EXPIRATION DATE. THIS OCCURRED ON 2800 OCCASIONS. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: IT WAS REPORTED THAT 14 CASES DO NOT HAVE A LOT OR AN EXPIRATION DATE PRINTED ON THEM.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
867192 SYRINGE 10ML LL S/C 200 PISTON SYRINGE FMF BECTON DICKINSON MEDICAL SYSTEMS 8213944 00382903029952

Patients

Seq Age Sex Outcome Treatment
1