NEEDLE FILTER BLUNT FILL 18X1-1/2
Report
- Report Number
- 1911916-2021-00512
- Event Type
- Malfunction
- Date Received
- June 3, 2021
- Date of Event
- May 5, 2021
- Report Date
- May 21, 2021
- Manufacturer
- BD MEDICAL (BD WEST) MEDICAL SURGICAL
- Product Code
- GAA
- UDI-DI
- 30382903052111
- PMA / PMN Number
- EXEMPT
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- SZ
- Reporter Occupation
- OTHER HEALTH CARE PROFESSIONAL
Narratives
DATE OF EVENT: UNKNOWN. THE DATE RECEIVED BY MANUFACTURER HAS BEEN USED FOR THIS FIELD. MULTIPLE LOT NUMBERS: THERE WERE MULTIPLE LOT NUMBERS REPORTED TO BE INVOLVED. THE INFORMATION FOR EACH LOT NUMBER IS AS FOLLOWS: MEDICAL DEVICE LOT #: 8250854, MEDICAL DEVICE EXPIRATION DATE: 2023-11-30, DEVICE MANUFACTURE DATE: (B)(6) 2018. MEDICAL DEVICE LOT #: 8361988, MEDICAL DEVICE EXPIRATION DATE: 2024-02-29, DEVICE MANUFACTURE DATE: (B)(6) 2018. INVESTIGATION SUMMARY: A DEVICE HISTORY RECORD REVIEW WAS COMPLETED BY OUR QUALITY ENGINEER TEAM FOR PROVIDED MATERIAL NUMBER 305211 AND LOT NUMBER 8250854. A DEVICE HISTORY RECORD REVIEW WAS COMPLETED BY OUR QUALITY ENGINEER TEAM FOR PROVIDED MATERIAL NUMBER 305211 AND LOT NUMBER 8361988. THE REVIEW DID NOT REVEAL ANY DETECTED ABNORMALITIES DURING THE PRODUCTION PROCESS THAT COULD HAVE CONTRIBUTED TO THIS DEFECT AND ALL QUALITY TESTS WERE FOUND TO BE WITHIN SPECIFICATION. AS A SAMPLE WAS UNAVAILABLE FOR RETURN, A THOROUGH SAMPLE INVESTIGATION COULD NOT BE COMPLETED. BASED ON THE INVESTIGATION RESULTS, AN EXACT CAUSE FOR THIS INCIDENT COULD NOT BE IDENTIFIED. THERE ARE QUALITY CONTROLS CURRENTLY IN PLACE TO DETECT THIS TYPE OF DEFECT DURING THE PRODUCTION PROCESS. FURTHER ACTION HAS NOT BEEN DETERMINED NECESSARY AT THIS TIME. COMPLAINTS RECEIVED FOR THIS DEVICE AND REPORTED CONDITION WILL CONTINUE TO BE TRACKED AND TRENDED. OUR QUALITY TEAM REGULARLY REVIEWS THE COLLECTED DATA FOR IDENTIFICATION OF EMERGING TRENDS.
IT WAS REPORTED THAT 3 NEEDLE FILTER BLUNT FILL 18X1-1/2 CONTAINED FOREIGN MATTER AND WERE CLOGGED. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: ¿WHITE FOREIGN MATERIAL ON FILTER NEEDLE. THE CUSTOMER DESCRIBED THAT THIS MATERIAL SEEMS TO BE PART OF WHITE PAINT AND LOCATED AROUND THE LUER.¿
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 826125 | NEEDLE FILTER BLUNT FILL 18X1-1/2 | MANUAL SURGICAL INSTRUMENT FOR GENERAL USE | GAA | BD MEDICAL (BD WEST) MEDICAL SURGICAL | 305211 | SEE H.10. | 30382903052111 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 |