FDA Adverse Event Death Summary report: Y

PUREWICK FEMALE EXTERNAL CATHETER

MDR report key: 11913935 · Received June 1, 2021

Report

Report Number
1018233-2021-03158
Event Type
Death
Date Received
June 1, 2021
Date of Event
May 8, 2021
Report Date
June 29, 2021
Manufacturer
C.R. BARD, INC. (COVINGTON) -1018233
Product Code
NZU
UDI-DI
00801741189050
PMA / PMN Number
EXEMPT
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
FL, US
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 0

THE REPORTED EVENT WAS INCONCLUSIVE AS NO SAMPLE RETURNED FOR EVALUATION. IT WAS UNKNOWN WHETHER THE DEVICE HAD MET RELEVANT SPECIFICATIONS. THE PRODUCT WAS USED FOR UROLOGICAL CARE. IT WAS UNKNOWN WHETHER THE PRODUCT HAD CAUSED THE REPORTED FAILURE. A POTENTIAL ROOT CAUSE FOR THIS FAILURE MODE COULD BE DUE TO THE MATERIAL SURFACE WAS ROUGH OR ABRASIVE OR UNCOMFORTABLE. THE DEVICE WAS NOT RETURNED FOR EVALUATION. THE LOT NUMBER WAS UNKNOWN THEREFORE THE DEVICE HISTORY RECORD COULD NOT BE REVIEWED. THE INSTRUCTIONS FOR USE WERE FOUND ADEQUATE AND STATE THE FOLLOWING: "INSTRUCTIONS FOR USE SETUP: 1. CONNECT THE CANISTER TO WALL SUCTION AND SET TO A MINIMUM OF 40MMHG CONTINUOUS SUCTION. ALWAYS USE THE MINIMUM AMOUNT OF SUCTION NECESSARY. IF USING THE DRYDOCTM VACUUM STATION, CONNECT THE CANISTER TO THE UNIT AND TURN THE UNIT ON. PLEASE CONSULT THE DRYDOCTM VACUUM STATION USER GUIDE FOR FURTHER INFORMATION. 2. USING THE STANDARD SUCTION TUBING, CONNECT THE PUREWICKTM FEMALE EXTERNAL CATHETER TO THE COLLECTION CANISTER. PERI-CARE AND PLACEMENT: 3. PERFORM PERINEAL CARE AND ASSESS SKIN INTEGRITY (DOCUMENT PER HOSPITAL PROTOCOL). SEPARATE LEGS, GLUTEUS MUSCLES, AND LABIA. PALPATE PUBIC BONE AS ANATOMICAL MARKER. 4. WITH SOFT GAUZE SIDE FACING PATIENT, ALIGN DISTAL END OF THE PUREWICKTM FEMALE EXTERNAL CATHETER AT GLUTEAL CLEFT. GENTLY TUCK SOFT GAUZE SIDE BETWEEN SEPARATED GLUTEUS AND LABIA. ENSURE THAT THE TOP OF THE GAUZE IS ALIGNED WITH THE PUBIC BONE. SLOWLY PLACE LEGS BACK TOGETHER ONCE THE PUREWICKTM FEMALE EXTERNAL CATHETER IS POSITIONED. NOTES: PATIENT CAN BE POSITIONED ON BACK, SIDE LYING, FROG LEGGED, OR LYING ON BACK WITH KNEES BENT AND THIGHS APART (LITHOTOMY POSITION) PRIOR TO DEVICE PLACEMENT. REMOVAL: 5. TO REMOVE THE PUREWICKTM FEMALE EXTERNAL CATHETER, FULLY SEPARATE THE LEGS, GLUTEUS, AND LABIA. TO AVOID POTENTIAL SKIN INJURY UPON REMOVAL, GENTLY PULL THE PUREWICKTM FEMALE EXTERNAL CATHETER DIRECTLY OUTWARD. ENSURE SUCTION IS MAINTAINED WHILE REMOVING THE PUREWICKTM FEMALE EXTERNAL CATHETER. AFTER USE, THIS PRODUCT MAY BE A POTENTIAL BIOHAZARD. DISPOSE OF IN ACCORDANCE WITH APPLICABLE LOCAL, STATE AND FEDERAL LAWS AND REGULATIONS. MAINTENANCE: 6. REPLACE THE PUREWICKTM FEMALE EXTERNAL CATHETER AT LEAST EVERY 8-12 HOURS OR IF SOILED WITH FECES OR BLOOD. ALWAYS ASSESS SKIN FOR COMPROMISE AND PERFORM PERINEAL CARE PRIOR TO PLACEMENT OF A NEW PUREWICKTM FEMALE EXTERNAL CATHETER. INDICATIONS FOR USE: THE PUREWICKTM FEMALE EXTERNAL CATHETER IS INTENDED FOR NON-INVASIVE URINE OUTPUT MANAGEMENT IN FEMALE PATIENTS. CONTRADICTIONS: PATIENT WITH URINARY RETENTION. WARNINGS: DO NOT USE THE PUREWICKTM FEMALE EXTERNAL CATHETER WITH BEDPAN OR ANY MATERIAL THAT DOES NOT ALLOW FOR SUFFICIENT AIRFLOW. TO AVOID POTENTIAL SKIN INJURY, NEVER PUSH OR PULL THE PUREWICKTM FEMALE EXTERNAL CATHETER AGAINST THE SKIN DURING PLACEMENT OR REMOVAL. NEVER INSERT THE PUREWICKTM FEMALE EXTERNAL CATHETER INTO VAGINA, ANAL CANAL, OR OTHER BODY CAVITIES. DISCONTINUE USE IF AN ALLERGIC REACTION OCCURS. AFTER USE, THIS PRODUCT MAY BE A POTENTIAL BIOHAZARD. DISPOSE OF IN ACCORDANCE WITH APPLICABLE LOCAL, STATE AND FEDERAL LAWS AND REGULATIONS. PRECAUTIONS: NOT RECOMMENDED FOR PATIENTS WHO ARE: AGITATED, COMBATIVE, OR UNCOOPERATIVE AND MIGHT REMOVE THE PUREWICK TM FEMALE EXTERNAL CATHETER HAVING FREQUENT EPISODES OF BOWEL INCONTINENCE WITHOUT A FECAL MANAGEMENT SYSTEM IN PLACE. EXPERIENCING SKIN IRRITATION OR COMPROMISE AT THE SITE. EXPERIENCING MODERATE/HEAVY MENSTRUATION AND CANNOT USE A TAMPON. DO NOT USE BARRIER CREAM ON THE PERINEUM WHEN USING THE PUREWICKTM FEMALE EXTERNAL CATHETER. BARRIER CREAM MAY IMPEDE SUCTION. PROCEED WITH CAUTION IN PATIENTS WHO HAVE UNDERGONE RECENT SURGERY OF THE EXTERNAL UROGENITAL TRACT. ALWAYS ASSESS SKIN FOR COMPROMISE AND PERFORM PERINEAL CARE PRIOR TO PLACEMENT OF A NEW PUREWICKTM FEMALE EXTERNAL CATHETER. MAINTAIN SUCTION UNTIL THE PUREWICKTM FEMALE EXTERNAL CATHETER IS FULLY REMOVED FROM THE PATIENT TO AVOID URINE BACK FLOW. RECOMMENDATIONS: PERFORM EACH STEP WITH CLEAN TECHNIQUE. IN THE HOME SETTING, WASH HANDS THOROUGHLY BEFORE DEVICE PLACEMENT. PRIOR TO CONNECTING THE PUREWICKTM FEMALE EXTERNAL CATHETER TO HOSPITAL WALL SUCTION TUBING, VERIFY SUCTION FUNCTION BY COVERING THE OPEN END OF THE SUCTION TUBING WITH ONE HAND AND OBSERVING THE PRESSURE DIAL. IF THE PRESSURE DOES NOT INCREASE WHEN THE LINE IS COVERED, VERIFY THAT THE TUBING IS SECURED, CONNECTED, AND NOT KINKED. ENSURE THE PUREWICKTM FEMALE EXTERNAL CATHETER REMAINS IN THE CORRECT POSITION AFTER TURNING THE PATIENT. REMOVE THE PUREWICKTM FEMALE EXTERNAL CATHETER PRIOR TO AMBULATION. PROPERLY PLACING THE PUREWICKTM FEMALE EXTERNAL CATHETER SNUGLY BETWEEN THE LABIA AND GLUTEUS HOLDS THE PUREWICKTM FEMALE EXTERNAL CATHETER IN PLACE FOR MOST PATIENTS. MESH UNDERWEAR MAY BE USEFUL FOR SECURING THE PUREWICKTM FEMALE EXTERNAL CATHETER FOR SOME PATIENTS. ASSESS DEVICE PLACEMENT AND PATIENT¿S SKIN AT LEAST EVERY 2 HOURS. REPLACE THE PUREWICKTM FEMALE EXTERNAL CATHETER EVERY 8-12 HOURS OR IF SOILED WITH FECES OR BLOOD. CHANGE SUCTION TUBING PER HOSPITAL PROTOCOL OR AT LEAST EVERY THIRTY (30) DAYS." CORRECTION: B, E, H. H11: SECTION A THROUGH F - THE INFORMATION PROVIDED BY BD REPRESENTS ALL THE KNOWN INFORMATION AT THIS TIME. DESPITE GOOD FAITH EFFORTS TO OBTAIN ADDITIONAL INFORMATION, THE COMPLAINANT / REPORTER WAS UNABLE OR UNWILLING TO PROVIDE ANY FURTHER PATIENT, PRODUCT, OR PROCEDURAL DETAILS TO BD. H3 OTHER TEXT : THE DEVICE WAS NOT RETURNED.

Description of Event or Problem · 0

IT WAS REPORTED THAT THE PATIENT EXPERIENCED A URINARY TRACT INFECTION AND WAS SEPTIC. THE PATIENT WAS ADMITTED TO THE HOSPITAL FOR ALMOST THREE WEEKS AND CRITICAL FOR OVER A WEEK UNTIL THE SEPTIC SHOCK SUBSIDED. ALSO STATED THAT THE COMPLAINANT THOUGHT IT MIGHT BE BECAUSE THE PATIENT WAS BEING FRUGAL AND REUSING THE PUREWICK FEMALE EXTERNAL CATHETERS. IT IS UNKNOWN WHAT MEDICAL INTERVENTION WAS PROVIDED FOR THE URINARY TRACT INFECTIONS. PER CUSTOMER VIA PHONE ON (B)(6) 2021 THE CALLER STATED THAT THE PATIENT EXPERIENCED A URINARY TRACT INFECTION FROM THE PUREWICK AND WAS SEPTIC. THE PATIENT EXPIRED A MONTH AGO. PER RETURN PHONE CALL ON (B)(6) 2021 FROM THE PATIENTS DAUGHTER IT WAS STATED THAT HER MOTHER WAS 96 YEARS OLD AND HAD MULTIPLE MEDICAL ISSUES INCLUDING A RECENT HEART SURGERY. THE FACILITY TOLD THAT THE CAUSE OF DEATH WAS DUE TO CARDIOGENIC SHOCK WHICH LIKELY STEMMED FROM A URINARY TRACT INFECTION THAT DEVELOPED INTO SEPSIS AFTER USING THE PUREWICK DEVICE. HOWEVER THE PATIENTS DAUGHTER STATED THAT THERE WAS NEVER ANY ISSUES WITH THE DEVICE LEAKING OR NOT SUCTIONING DURING THE USE AT HOME.

Additional Manufacturer Narrative · 1

THE INVESTIGATION IS STILL IN PROGRESS. ONCE THE INVESTIGATION IS COMPLETE A SUPPLEMENTAL REPORT WILL BE FILED.

Description of Event or Problem · 1

IT WAS REPORTED THAT THE PATIENT GOT URINARY TRACT INFECTION AND WAS SEPTIC. THE PATIENT WAS ADMITTED TO THE HOSPITAL FOR ALMOST THREE WEEKS AND CRITICAL FOR OVER A WEEK UNTIL THE SEPTIC SHOCK SUBSIDED. ALSO STATED THAT THE COMPLAINANT THOUGHT IT MIGHT BE BECAUSE THE PATIENT WAS BEING FRUGAL AND REUSING THE PUREWICK FEMALE EXTERNAL CATHETERS. IT WAS UNKNOWN WHAT MEDICAL INTERVENTION WAS PROVIDED FOR URINARY TRACT INFECTIONS.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
810118 PUREWICK FEMALE EXTERNAL CATHETER PUREWICK FEMALE EXTERNAL CATHETER NZU C.R. BARD, INC. (COVINGTON) -1018233 PWFX30 UNK 00801741189050

Patients

Seq Age Sex Outcome Treatment
1 96 YR Death| O