MDR report key: 11874400 · Received May 25, 2021

Report

Report Number
1911916-2021-00473
Event Type
Malfunction
Date Received
May 25, 2021
Date of Event
April 23, 2021
Report Date
June 4, 2021
Manufacturer
BD MEDICAL (BD WEST) MEDICAL SURGICAL
Product Code
NGT
UDI-DI
00382903065462
PMA / PMN Number
D346482
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
HK
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 0

THE FOLLOWING FIELDS WERE UPDATED DUE TO ADDITIONAL INFORMATION: D.10. DEVICE AVAILABLE FOR EVAL?: YES D.10. RETURNED TO MANUFACTURER ON: 6/3/2021 H.6. INVESTIGATION: IT WAS REPORTED IT WAS HARD TO PUSH THE PLUNGER OF THE SYRINGE. TO AID IN THE INVESTIGATION, ONE SAMPLE IN A SEALED PACKAGING FLOW WRAP AND ONE PHOTO WERE RECEIVED FOR EVALUATION BY OUR QUALITY TEAM. A VISUAL INSPECTION WAS PERFORMED ON THE SAMPLE AND NO DEFECTS OR IMPERFECTIONS WERE OBSERVED. THE SAMPLE WAS THEN TESTED FOR SUSTAINING FORCE, WHICH IS THE FORCE APPLIED TO THE PLUNGER ROD WHILE MOVING DOWNWARDS WHEN EXPELLING THE SALINE SOLUTION, AND THE RESULT WAS WITHIN SPECIFICATION. THE PHOTO PROVIDED SHOWS THE SAMPLE RECEIVED. IT COULD BE POSSIBLE THE CUSTOMER HAD PRODUCT ON THE HIGHER END OF SPECIFICATION INDUCING MORE FORCE THAN NORMAL REQUIRED TO EXPEL THE SOLUTION. A DEVICE HISTORY RECORD REVIEW WAS COMPLETED FOR PROVIDED MATERIAL NUMBER 306546, LOT 0223825. THE REVIEW DID NOT REVEAL ANY DETECTED QUALITY ISSUES DURING THE PRODUCTION OF THIS LOT THAT COULD HAVE CONTRIBUTED TO THE REPORTED DEFECT. SEE H.10

Description of Event or Problem · 0

IT WAS REPORTED THAT SYRINGE 10ML REG PR SALINE 10ML FILL PLUNGER MOVEMENT WAS DIFFICULT. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: THE CUSTOMER COMPLAINED THAT IT WAS HARD TO PUSH THE PLUNGER OF THE SYRINGE.

Additional Manufacturer Narrative · 1

A DEVICE EVALUATION AND/OR DEVICE HISTORY REVIEW IS ANTICIPATED, BUT IS NOT COMPLETE. UPON COMPLETION, A SUPPLEMENTAL REPORT WILL BE FILED.

Description of Event or Problem · 1

IT WAS REPORTED THAT SYRINGE 10ML REG PR SALINE 10ML FILL PLUNGER MOVEMENT WAS DIFFICULT. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: THE CUSTOMER COMPLAINED THAT IT WAS HARD TO PUSH THE PLUNGER OF THE SYRINGE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
772872 SYRINGE 10ML REG PR SALINE 10ML FILL SALINE, VASCULAR ACCESS FLUSH NGT BD MEDICAL (BD WEST) MEDICAL SURGICAL 0223825 00382903065462

Patients

Seq Age Sex Outcome Treatment
1