MAZOR X STEALTH EDITION
Report
- Report Number
- 3005075696-2021-00061
- Event Type
- Malfunction
- Date Received
- May 21, 2021
- Date of Event
- May 5, 2021
- Report Date
- May 28, 2021
- Manufacturer
- MAZOR ROBOTICS LTD
- Product Code
- OLO
- UDI-DI
- 07290109183213
- PMA / PMN Number
- K182077
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- NV, US
- Reporter Occupation
- PHYSICIAN
Narratives
MEDTRONIC IS SUBMITTING THIS REPORT TO COMPLY WITH FDA REPORTING REGULATIONS UNDER 21 CFR PARTS 4 AND 803. THIS REPORT IS BASED UPON INFORMATION OBTAINED BY MEDTRONIC, WHICH THE COMPANY MAY NOT HAVE BEEN ABLE TO FULLY INVESTIGATE OR VERIFY PRIOR TO THE DATE THE REPORT WAS REQUIRED BY THE FDA. MEDTRONIC HAS MADE REASONABLE EFFORTS TO OBTAIN MORE COMPLETE INFORMATION AND HAS PROVIDED AS MUCH RELEVANT INFORMATION AS IS AVAILABLE TO THE COMPANY AS OF THE SUBMISSION DATE OF THIS REPORT. THIS REPORT DOES NOT CONSTITUTE AN ADMISSION OR A CONCLUSION BY FDA, MEDTRONIC, OR ITS EMPLOYEES THAT THE DEVICE, MEDTRONIC, OR ITS EMPLOYEE CAUSED OR CONTRIBUTED TO THE EVENT DESCRIBED IN THE REPORT. IN PARTICULAR, THIS REPORT DOES NOT CONSTITUTE AN ADMISSION BY ANYONE THAT THE PRODUCT DESCRIBED IN THIS REPORT HAS ANY ¿DEFECTS¿ OR HAS ¿MALFUNCTIONED¿. THESE WORDS ARE INCLUDED IN THE FDA 3500A FORM AND ARE FIXED ITEMS FOR SELECTION CREATED BY THE FDA TO CATEGORIZE THE TYPE OF EVENT SOLELY FOR THE PURPOSE OF REGULATORY REPORTING. MEDTRONIC OBJECTS TO THE USE OF THESE WORDS AND OTHERS LIKE THEM BECAUSE OF THE LACK OF DEFINITION AND THE CONNOTATIONS IMPLIED BY THESE TERMS. THIS STATEMENT SHOULD BE INCLUDED WITH ANY INFORMATION OR REPORT DISCLOSED TO THE PUBLIC UNDER THE FREEDOM OF INFORMATION ACT. ANY REQUIRED FIELDS THAT ARE UNPOPULATED ARE BLANK BECAUSE THE INFORMATION IS CURRENTLY UNKNOWN OR UNAVAILABLE. A GOOD FAITH EFFORT WILL BE MADE TO OBTAIN THE APPLICABLE INFORMATION RELEVANT TO THE REPORT. IF INFORMATION IS PROVIDED IN THE FUTURE, A SUPPLEMENTAL REPORT WILL BE ISSUED.
ADDITIONAL INFORMATION RECEIVED FROM A MANUFACTURER REPRESENTATIVE REPORTED THAT THE SYSTEM PASSED AN ADVANCED ACCURACY CHECK AFTER THE PROCEDURE.
IF INFORMATION IS PROVIDED IN THE FUTURE, A SUPPLEMENTAL REPORT WILL BE ISSUED.
MEDTRONIC RECEIVED INFORMATION REGARDING A GUIDANCE SYSTEM BEING USED DURING A SPINAL PROCEDURE TO TREAT DEGENERATIVE DISCS WITH FIXATION USING SCREWS AND RODS. IT WAS REPORTED THAT THE LEFT L5 TRAJECTORY WAS DEVIATED DURING A L4-L5 PROCEDURE. THE SCREW WAS DEVIATED LESS THAN 3.5 MM. TROUBLESHOOTING INVOLVED DOING AN ACCURACY CHECK AND USING A BALL TIP PROBE IN THE HOLE AFTER THE SCREW WAS REMOVED. THE SCREW WAS A LITTLE LOW, BUT LOOKED GOOD ON FLUORO. WHEN NEUROMONITORING WAS DONE, THE SCREW TESTED AT 9 WHICH WAS LOW. THE PEDICLE LOOKED FRACTURED AND MAY HAVE BEEN THE CAUSE OF THE LOW NEUROMONITORING. THE POST-OP IMAGING WERE CHECKED AND THEY LOOKED GOOD, BUT THE SURGEON WAS CONCERNED ABOUT HOW THE SCREW TESTED AND SUSPECTED A MEDIAL BREACH. THE SCREW WAS LEFT IMPLANTED AND NO CHANGES WERE MADE. THERE WAS NO PATIENT HARM AND THE PROCEDURE WAS DELAYED LESS THAN AN HOUR.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 763963 | MAZOR X STEALTH EDITION | OLO | MAZOR ROBOTICS LTD | TPL0059 | 07290109183213 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 63 YR |