FDA Adverse Event Malfunction Summary report: N

BD PHASEAL OPTIMA INFUSION CLAMP M25-O

MDR report key: 11823075 · Received May 13, 2021

Report

Report Number
2243072-2021-01461
Event Type
Malfunction
Date Received
May 13, 2021
Date of Event
April 14, 2021
Report Date
June 24, 2021
Manufacturer
BECTON DICKINSON
Product Code
KMK
UDI-DI
00382905150852
PMA / PMN Number
PREAMENDMENT
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
CA, US
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 0

THE FOLLOWING FIELDS WERE UPDATED DUE TO ADDITIONAL INFORMATION: D10: DEVICE AVAILABLE FOR EVAL YES, D10: RETURNED TO MANUFACTURER ON: 2021-05-21. H6: INVESTIGATION SUMMARY: ONE SAMPLE WAS PROVIDED TO OUR QUALITY TEAM FOR INVESTIGATION. UPON VISUAL INSPECTION, THE LATCH MECHANISM WAS OBSERVED TO BE BENT. A REVIEW OF LOT 2004106 WAS PERFORMED, ALL SAMPLES WERE 100% INSPECTED FOR PRODUCT FUNCTION AND NO DEVIATIONS WERE IDENTIFIED DURING THE MANUFACTURING OF THIS LOT THAT COULD CONTRIBUTE TO THE REPORTED FAILURE. TWENTY FIVE SAMPLES OF LOT 2004106 WERE USED FOR ADDITIONAL EVALUATION, ALL PRODUCT WAS INSPECTED AND NO SAMPLES WAS OBSERVED TO HAVE A BENT LOCKING MECHANISM. BASED ON OUR QUALITY TEAM'S INVESTIGATION, IT LIKELY THE LATCH BENT DUE TO FORCE APPLIED TO THE DEVICE WHILE IN THE INCORRECT POSITION. COMPLAINTS RECEIVED FOR THIS DEFECT AND DEVICE WILL CONTINUE TO BE MONITORED BY OUR QUALITY TEAM FOR SIGNS OF EMERGING TRENDS. H3 OTHER TEXT : SEE H10.

Description of Event or Problem · 0

IT WAS REPORTED THAT WHILE USING BD PHASEAL¿ OPTIMA INFUSION CLAMP M25-O THE CLAMPS ARE NOT SNAPPING CLOSED. THIS OCCURRED WITH 10 CLAMPS. THERE WAS NO REPORT OF PATIENT IMPACT. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: IT WAS REPORTED THAT MANY OF THE INFUSION CLAMPS ARE NOT SNAPPING CLOSE.

Additional Manufacturer Narrative · 1

FOR OEM MANUFACTURING SITES: (B)(4). A DEVICE EVALUATION IS ANTICIPATED, BUT HAS NOT YET BEGUN. UPON COMPLETION OF THE INVESTIGATION, A SUPPLEMENTAL REPORT WILL BE FILED.

Description of Event or Problem · 1

IT WAS REPORTED THAT WHILE USING BD PHASEAL¿ OPTIMA INFUSION CLAMP M25-O THE CLAMPS ARE NOT SNAPPING CLOSED. THIS OCCURRED WITH 10 CLAMPS. THERE WAS NO REPORT OF PATIENT IMPACT. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: IT WAS REPORTED THAT MANY OF THE INFUSION CLAMPS ARE NOT SNAPPING CLOSE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
719958 BD PHASEAL OPTIMA INFUSION CLAMP M25-O DEVICE, INTRAVASCULAR CATHETER SECUREMENT KMK BECTON DICKINSON 515085 2004106 00382905150852

Patients

Seq Age Sex Outcome Treatment
1