FDA Adverse Event Injury Summary report: N

ESSURE

MDR report key: 11810419 · Received May 11, 2021

Report

Report Number
2951250-2021-01960
Event Type
Injury
Date Received
May 11, 2021
Report Date
June 9, 2021
Manufacturer
BAYER PHARMA AG
Product Code
HHS
UDI-DI
10888853003051
PMA / PMN Number
P020014
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
US
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 0

THIS SPONTANEOUS CASE WAS REPORTED BY A LAWYER AND DESCRIBES THE OCCURRENCE OF MEDICAL DEVICE REMOVAL ('MEDICAL DEVICE REMOVAL') IN AN ADULT FEMALE PATIENT WHO HAD ESSURE INSERTED FOR FEMALE STERILISATION. THE PATIENT'S MEDICAL HISTORY INCLUDED FIBROIDS, MENORRHAGIA, DYSMENORRHEA, ADENOMYOSIS AND PARATUBAL CYST. ON (B)(6) 2010, THE PATIENT HAD ESSURE INSERTED. ON AN UNKNOWN DATE, THE PATIENT UNDERWENT MEDICAL DEVICE REMOVAL (SERIOUSNESS CRITERIA MEDICALLY SIGNIFICANT AND INTERVENTION REQUIRED). THE PATIENT WAS TREATED WITH SURGERY (LAPAROSCOPICALLY-ASSISTED SUPRACERVICAL HYSTERECTOMY WITH A MINI-LAPAROTOMY PROCEDURE). ESSURE WAS REMOVED ON (B)(6) 2016. AT THE TIME OF THE REPORT, THE MEDICAL DEVICE REMOVAL OUTCOME WAS UNKNOWN. THE REPORTER CONSIDERED MEDICAL DEVICE REMOVAL TO BE RELATED TO ESSURE. DIAGNOSTIC RESULTS (NORMAL RANGES ARE PROVIDED IN PARENTHESIS IF AVAILABLE): PATHOLOGY TEST - ON (B)(6) 2016: UTERUS AND FALLOPIAN TUBES (SUP.RACERVICAL HYSTERECTOMY. BILATERAL. SALPINGECTOMY): HIGH ENDOCERVICAL CANAL: ENDOCERVICAL ADENOMYOSIS AT CESAREAN SECTION SITE. ENDOMETRIUM: SECRETORY PHASE. WITHOUT HYPERPLASIA, ATYPIA. OR MALIGNANCY, MYOMETRIUM: LEIOMYOMATA (LARGEST 7.5 CM, WITH SOME CALCIFICATIONS). SEROSA: NO PATHOLOGIC ABNORMALITIES. FALLOPIAN TUBES: BENIGN PARATUBAL CYSTS (LARGEST 1.0 CM), AND ESSURE COILS. QUALITY-SAFETY EVALUATION OF PTC: NO DEFECT COULD BE CONFIRMED BY THE MANUFACTURER. ALL PRODUCT BATCHES HAVE MET THE SPECIFICATIONS REGARDING LABELING, MATERIAL, AND PROCESS CONTROLS AT TIME OF RELEASE. TREND ANALYSES OF COMPLAINTS ARE REVIEWED REGULARLY; NO SIGNAL WAS OBSERVED WITH REGARD TO THE REPORTED COMPLAINT REASON. THE RISK MANAGEMENT FILE WAS REVIEWED AND AN UPDATE WAS NOT DEEMED REQUIRED. A TECHNICAL INVESTIGATION OF THE COMPLAINT SAMPLE AND BATCH RECORD REVIEW COULD NOT BE CONDUCTED, AS NO SAMPLE OR BATCH NUMBER WERE AVAILABLE. MOST RECENT FOLLOW-UP INFORMATION INCORPORATED ABOVE INCLUDES: ON 24-MAY-2021: MR RECEIVED-NEW REPORTER, LAB DATA, MEDICAL HISTORY, REMOVAL DETAILS WERE ADDED. BASED ON THE AVAILABLE INFORMATION, A REVIEW OF OUR COMPLAINT RECORDS AND OTHER RELEVANT DATA WAS CONDUCTED; ANY NEW AND REPORTABLE INFORMATION THAT BECOMES AVAILABLE FROM OUR INVESTIGATION WILL BE PROVIDED IN A SUPPLEMENTARY REPORT.

Additional Manufacturer Narrative · 0

THIS SPONTANEOUS CASE WAS REPORTED BY A LAWYER AND DESCRIBES THE OCCURRENCE OF MEDICAL DEVICE REMOVAL ('MEDICAL DEVICE REMOVAL') IN AN ADULT FEMALE PATIENT WHO HAD ESSURE INSERTED FOR FEMALE STERILISATION. THE PATIENT'S MEDICAL HISTORY INCLUDED FIBROIDS, MENORRHAGIA, DYSMENORRHEA, ADENOMYOSIS AND PARATUBAL CYST. ON (B)(6) 2010, THE PATIENT HAD ESSURE INSERTED. ON AN UNKNOWN DATE, THE PATIENT UNDERWENT MEDICAL DEVICE REMOVAL (SERIOUSNESS CRITERIA MEDICALLY SIGNIFICANT AND INTERVENTION REQUIRED). THE PATIENT WAS TREATED WITH SURGERY (LAPAROSCOPICALLY-ASSISTED SUPRACERVICAL HYSTERECTOMY WITH A MINI-LAPAROTOMY PROCEDURE). ESSURE WAS REMOVED ON (B)(6) 2016. AT THE TIME OF THE REPORT, THE MEDICAL DEVICE REMOVAL OUTCOME WAS UNKNOWN. THE REPORTER CONSIDERED MEDICAL DEVICE REMOVAL TO BE RELATED TO ESSURE. DIAGNOSTIC RESULTS (NORMAL RANGES ARE PROVIDED IN PARENTHESIS IF AVAILABLE): PATHOLOGY TEST - ON (B)(6) 2016: UTERUS AND FALLOPIAN TUBES (SUP.RACERVICAL HYSTERECTOMY. BILATERAL SALPINGECTOMY): HIGH ENDOCERVICAL CANAL: ENDOCERVICAL ADENOMYOSIS AT CESAREAN SECTION SITE. ENDOMETRIUM: SECRETORY PHASE. WITHOUT HYPERPLASIA, ATYPIA. OR MALIGNANCY, MYOMETRIUM: LEIOMYOMATA (LARGEST 7.5 CM, WITH SOME CALCIFICATIONS). SEROSA: NO PATHOLOGIC ABNORMALITIES FALLOPIAN TUBES: BENIGN PARATUBAL CYSTS (LARGEST 1.0 CM), AND ESSURE COILS.. QUALITY-SAFETY EVALUATION OF PTC: NO DEFECT COULD BE CONFIRMED BY THE MANUFACTURER. ALL PRODUCT BATCHES HAVE MET THE SPECIFICATIONS REGARDING LABELING, MATERIAL, AND PROCESS CONTROLS AT TIME OF RELEASE. TREND ANALYSES OF COMPLAINTS ARE REVIEWED REGULARLY, NO SIGNAL WAS OBSERVED WITH REGARD TO THE REPORTED COMPLAINT REASON. THE RISK MANAGEMENT FILE WAS REVIEWED AND AN UPDATE WAS NOT DEEMED REQUIRED. A TECHNICAL INVESTIGATION OF THE COMPLAINT SAMPLE AND BATCH RECORD REVIEW COULD NOT BE CONDUCTED, AS NO SAMPLE OR BATCH NUMBER WERE AVAILABLE. MOST RECENT FOLLOW-UP INFORMATION INCORPORATED ABOVE INCLUDES: ON 7-JUN-2021: QUALITY-SAFETY EVALUATION OF PTC. BASED ON THE AVAILABLE INFORMATION, A REVIEW OF OUR COMPLAINT RECORDS AND OTHER RELEVANT DATA WAS CONDUCTED; ANY NEW AND REPORTABLE INFORMATION THAT BECOMES AVAILABLE FROM OUR INVESTIGATION WILL BE PROVIDED IN A SUPPLEMENTARY REPORT.

Description of Event or Problem · 1

THIS SPONTANEOUS CASE WAS REPORTED BY A LAWYER AND DESCRIBES THE OCCURRENCE OF MEDICAL DEVICE REMOVAL ('MEDICAL DEVICE REMOVAL') IN AN ADULT FEMALE PATIENT WHO HAD ESSURE INSERTED FOR FEMALE STERILISATION. ON (B)(6) 2010, THE PATIENT HAD ESSURE INSERTED. ON AN UNKNOWN DATE, THE PATIENT UNDERWENT MEDICAL DEVICE REMOVAL (SERIOUSNESS CRITERIA MEDICALLY SIGNIFICANT AND INTERVENTION REQUIRED). THE PATIENT WAS TREATED WITH SURGERY (REMOVAL ON (B)(6) 2016). ESSURE WAS REMOVED ON (B)(6) 2016. AT THE TIME OF THE REPORT, THE MEDICAL DEVICE REMOVAL OUTCOME WAS UNKNOWN. THE REPORTER CONSIDERED MEDICAL DEVICE REMOVAL TO BE RELATED TO ESSURE. QUALITY-SAFETY EVALUATION OF PTC: NO DEFECT COULD BE CONFIRMED BY THE MANUFACTURER. ALL PRODUCT BATCHES HAVE MET THE SPECIFICATIONS REGARDING LABELING, MATERIAL, AND PROCESS CONTROLS AT TIME OF RELEASE. TREND ANALYSES OF COMPLAINTS ARE REVIEWED REGULARLY; NO SIGNAL WAS OBSERVED WITH REGARD TO THE REPORTED COMPLAINT REASON. THE RISK MANAGEMENT FILE WAS REVIEWED AND AN UPDATE WAS NOT DEEMED REQUIRED. A TECHNICAL INVESTIGATION OF THE COMPLAINT SAMPLE AND BATCH RECORD REVIEW COULD NOT BE CONDUCTED, AS NO SAMPLE OR BATCH NUMBER WERE AVAILABLE MOST RECENT FOLLOW-UP INFORMATION INCORPORATED ABOVE INCLUDES: ON 28-APR-2021: THIS CASE BECOME SERIOUS INCIDENT. PIF RECEIVED. PATIENT'S DATE OF BIRTH, EXPLANT DATE WERE ADDED. EVENT "INJURY" WAS UPDATED TO "MEDICAL DEVICE REMOVAL". BASED ON THE AVAILABLE INFORMATION, A REVIEW OF OUR COMPLAINT RECORDS AND OTHER RELEVANT DATA WAS CONDUCTED; ANY NEW AND REPORTABLE INFORMATION THAT BECOMES AVAILABLE FROM OUR INVESTIGATION WILL BE PROVIDED IN A SUPPLEMENTARY REPORT.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
706017 ESSURE TRANSCERVICAL CONTRACEPTIVE TUBAL OCCLUSION DEVICE HHS BAYER PHARMA AG ESS305 10888853003051

Patients

Seq Age Sex Outcome Treatment
1 Other| R