SYNCARDIA 70CC TEMPORARY TOTAL ARTIFICIAL HEART (TAH-T)
Report
- Report Number
- 3003761017-2021-00071
- Event Type
- Injury
- Date Received
- May 3, 2021
- Report Date
- April 26, 2021
- Manufacturer
- SYNCARDIA SYSTEMS, LLC
- Product Code
- LOZ
- PMA / PMN Number
- P030011
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- AZ, US
- Reporter Occupation
- 003
Narratives
THE SYNCARDIA 70CC TEMPORARY TOTAL ARTIFICIAL HEART (TAH-T) IS AN IMPLANTABLE PULSATILE BIVENTRICULAR REPLACEMENT DEVICE THAT REPLACES A PATIENT'S NATIVE VENTRICLES AND VALVES AND PUMPS BLOOD TO BOTH THE PULMONARY AND SYSTEMIC CIRCULATION SYSTEMS. THE SYNCARDIA 70CC TAH-T IS INDICATED FOR USE AS A BRIDGE TO TRANSPLANTATION IN CARDIAC TRANSPLANT-ELIGIBLE CANDIDATES AT RISK OF IMMINENT DEATH FROM BIVENTRICULAR FAILURE. THE SYNCARDIA TAH-T SYSTEM IS INTENDED FOR USE INSIDE AND OUTSIDE THE HOSPITAL. INVESTIGATION SUMMARY: INTERMACS PATIENT REGISTRY DATA COLLECTED FROM JULY 1, 2019 THROUGH SEPTEMBER 30, 2020 REGARDING ADVERSE EVENTS WAS REVIEWED. PATIENTS WERE DE-IDENTIFIED THEREFORE A ONE-TO-ONE CORRELATION COULD NOT BE MADE BETWEEN THE PATIENT AND THE LOT NUMBER OF THE IMPLANTED TAH-T. WITH A REVIEW OF THE AVAILABLE INFORMATION, THERE IS NO EVIDENCE OF A DEVICE MALFUNCTION OR PERFORMANCE ISSUES THAT WOULD IMPACT THE REPORTED EVENTS. POSSIBLE CLINICAL FACTORS THAT MAY HAVE CONTRIBUTED TO THESE EVENTS INCLUDE THE PATIENTS PRE-EXISTING HISTORY AND RELATED COMORBIDITIES, THE PROGRESSION OF THEIR UNDERLYING DISEASE, ISSUES RELATED TO THE THERAPEUTIC USE OF ANTICOAGULANTS, ANTIPLATELET MEDICATIONS AND THE PATIENT'S COMPLEX POST-OPERATIVE COURSE. THERE ARE POSSIBLE PATIENT, PHARMACOLOGICAL AND PROCEDURAL FACTORS THAT MAY HAVE CONTRIBUTED TO THESE EVENTS. THIS DEVICE IS USED FOR TREATMENT, NOT DIAGNOSIS. CE (B)(4).
WHILE SUPPORTED BY THE TAH-T, THE PATIENT EXPERIENCED THE FOLLOWING ADVERSE EVENTS AS DEFINED BY INTERMACS: 3 DAYS POST IMPLANT - NEUROLOGICAL DYSFUNCTION - CVA I LOCATION: RIGHT HEMISPHERE: TEMPORAL I SEVERITY: LEFT SIDED PARALYSIS. 3 DAYS POST IMPLANT - RESPIRATORY FAILURE. 50 DAYS POST IMPLANT - INFECTION I LOCATION POSITIVE BLOOD CULTURES, LINE SEPSIS I TYPE: BACTERIAL. 55 DAYS POST IMPLANT - PSYCHIATRIC EPISODE. 127 DAYS POST IMPLANT - RENAL DYSFUNCTION. 215 DAYS POST IMPLANT - NEUROLOGICAL DYSFUNCTION - SEIZURE. 266 DAYS POST IMPLANT - NEUROLOGICAL DYSFUNCTION - CVA I LOCATION: CEREBELLAR I SEVERITY: OTHER. THE PATIENT SUBSEQUENTLY RECEIVED A HEART TRANSPLANT AFTER 342 DAYS OF TAH-T SUPPORT.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 658754 | SYNCARDIA 70CC TEMPORARY TOTAL ARTIFICIAL HEART (TAH-T) | BIVENTRICULAR REPLACEMENT DEVICE | LOZ | SYNCARDIA SYSTEMS, LLC |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Other |