LAP-BAND ADJUSTABLE GASTRIC BANDING SYSTEM
Report
- Report Number
- 2024601-2008-00609
- Event Type
- Malfunction
- Date Received
- September 17, 2008
- Date of Event
- August 19, 2008
- Report Date
- August 19, 2008
- Manufacturer
- BIOENTERICS CORP
- Product Code
- LTI
- PMA / PMN Number
- P000008
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- BE
- Reporter Occupation
- OTHER
Narratives
TAPER UNK. THE REPORTER OF THE COMPLAINT WAS ASKED TO RETURN THE PRODUCT FOR ANALYSIS AS WELL AS INDICATE THE PRODUCT SERIAL NUMBER, DATE OF EVENT, IMPLANT DATE AND EXPLANT DATE. THE INFO HAS NOT YET BEEN RECEIVED BY ALLERGAN. THE CONNECTOR TYPE CANNOT BE IDENTIFIED NOR AN ASSUMPTION MADE AS TO THE TYPE OF CONNECTOR ASSOCIATED WITH THIS COMPLAINT BECAUSE NO SERIAL NUMBER OR IMPLANT DATE WAS GIVEN. VISUAL EXAMINATION MAY DETERMINE THE CONNECTOR TYPE ASSOCIATED WITH THIS REPORT. ALLERGAN HAS NOT RECEIVED THE PRODUCT AT THIS TIME. THEREFORE NO ANALYSIS OR TESTING HAS BEEN DONE. FURTHER INFO FROM THE REPORTER REGARDING SERIAL NUMBER AND IMPLANT DATE HAS BEEN REQUESTED. DEVICE LABELING ADDRESSES THE POSSIBLE OUTCOME OF LEAKAGE AS FOLLOWS: "DEFLATION OF THE BAND MAY OCCUR DUE TO LEAKAGE FROM THE BAND. THE PORT OR THE CONNECTOR TUBING."
REPORTED AS: "OUR GROUP PERFORMED A TOTAL LAPAROSCOPIC GASTRIC BANDINGS SINCE 1996, USING THE LAPBAND. WE DID A RETROSPECTIVE ANALYSIS ON COMPLICATIONS BETWEEN EARLY 2005 AND 2007. DURING THIS PERIOD, RE-INTERVENTIONS WERE PERFORMED FOR EITHER PORT (65%) OR BAND (35%) RELATED COMPLICATIONS. SOME PTS (13%) EXPERIENCED POSITIONAL PROBLEMS (DISLOCATION AND FLIPPING), IN SOME PTS (58%), PROBLEMS AROSE FROM THE TUBE AND/OR TUBE- PORT CONNECTION, SOME PATIENTS (19%), DEVELOPED AN INFECTION OF THE PORT, THREE PATIENTS (10%) EXPERIENCED SUBJECTIVE PROBLEMS SUCH AS PROMINENT VISIBILITY AND/OR DISCOMFORT." FROM LITERATURE REVIEW: JOURNAL ABSTRACT # 89 "PORT AND TUBE RELATED COMPLICATIONS IN LAPAROSCOPIC GASTRIC BANDING" S. PAULI, J. DERYCKER, M. VAN CLEEMPUT, DEURNE, BELGIUM; PUBLISHED IN "OBES SURG 2008" SPRINGER SCIENCE. THIS FILE ADDRESSES ONE OF THE COMPLAINTS OF LEAKAGE PROBLEMS THAT AROSE FROM THE TUBE AND/OR TUBE-PORT CONNECTION.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1 | LAP-BAND ADJUSTABLE GASTRIC BANDING SYSTEM | DEVICE FOR TREATMENT OF MORBID OBSEITY | LTI | BIOENTERICS CORP | NA | NI |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 |