FDA Adverse Event Malfunction Summary report: N

BD POSIFLUSH XS PRE-FILLED FLUSH SYRINGE NACL 0.9%

MDR report key: 11704602 · Received April 21, 2021

Report

Report Number
9616657-2021-00043
Event Type
Malfunction
Date Received
April 21, 2021
Date of Event
March 25, 2021
Report Date
June 4, 2021
Manufacturer
BECTON, DICKINSON AND CO.
Product Code
NGT
PMA / PMN Number
NA
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
GM
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 0

THE FOLLOWING FIELDS WERE UPDATED DUE TO ADDITIONAL INFORMATION: D.10. DEVICE AVAILABLE FOR EVAL?: YES. D.10. RETURNED TO MANUFACTURER ON: 5/10/2021. H.6. INVESTIGATION: A DEVICE HISTORY RECORD REVIEW WAS COMPLETED FOR PROVIDED LOT NUMBER 9213635. THE REVIEW DID NOT REVEAL ANY DETECTED ABNORMALITIES DURING THE PRODUCTION PROCESS THAT COULD HAVE CONTRIBUTED TO THE REPORTED DEFECTS AND ALL QUALITY TESTS WERE FOUND TO BE WITHIN SPECIFICATION. TO AID IN THE INVESTIGATION OF THIS ISSUE, BOTH PICTURE AND PHYSICAL SAMPLES WERE RETURNED FOR EVALUATION BY OUR QUALITY ENGINEER TEAM. THE SUPPLIED SAMPLE WAS RECEIVED OPENED WITHOUT THE BLISTER PACKAGING AND IT DISPLAYED AN UNDERFILL OF SALINE. IT IS POSSIBLE THAT AN INTERMITTENT AND ISOLATED ISSUE WITH THE TIP CAP TORQUE OCCURRED, RESULTING IN LEAKAGE OF SALINE THROUGH THE TIP CAP WHICH EVAPORATED IN THE BLISTER PACKAGING. HOWEVER, AS THE SAMPLE WAS OPENED, THIS EXACT CAUSE CANNOT BE CONFIRMED.

Description of Event or Problem · 0

IT WAS REPORTED THAT THE BD POSIFLUSH¿ XS PRE-FILLED FLUSH SYRINGE NACL 0.9% EXPERIENCED BEING A PREFILLED SYRINGE WITH A FILL THAT WAS LESS THAN DESIGN SPECIFICATIONS. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: BD-POSIFLUSH IS FILLED WITH LESS THAN 3ML.

Additional Manufacturer Narrative · 1

DATE OF EVENT: UNKNOWN. THE DATE RECEIVED BY MANUFACTURER HAS BEEN USED FOR THIS FIELD. INITIAL REPORTER PHONE #: (B)(6). A DEVICE EVALUATION IS ANTICIPATED, BUT HAS NOT YET BEGUN. UPON COMPLETION OF THE INVESTIGATION, A SUPPLEMENTAL REPORT WILL BE FILED.

Description of Event or Problem · 1

IT WAS REPORTED THAT THE BD POSIFLUSH¿ XS PRE-FILLED FLUSH SYRINGE NACL 0.9% EXPERIENCED BEING A PREFILLED SYRINGE WITH A FILL THAT WAS LESS THAN DESIGN SPECIFICATIONS. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: BD-POSIFLUSH IS FILLED WITH LESS THAN 3ML.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
596205 BD POSIFLUSH XS PRE-FILLED FLUSH SYRINGE NACL 0.9% PREFILLED SALINE SYRINGE NGT BECTON, DICKINSON AND CO. 9213635

Patients

Seq Age Sex Outcome Treatment
1