FDA Adverse Event Malfunction Summary report: N

D-DIMER

MDR report key: 11677067 · Received April 16, 2021

Report

Report Number
1823260-2021-01156
Event Type
Malfunction
Date Received
April 16, 2021
Date of Event
March 23, 2021
Report Date
April 16, 2021
Manufacturer
ROCHE DIAGNOSTICS
Product Code
GHH
PMA / PMN Number
K062203
Removal / Correction Number
NA
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
IN
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 1

RESULTS CAN DIFFER BETWEEN TESTS DUE TO DIFFERENT SPECIFICITY OF THE ANTIBODY USED OR OTHER TEST CHARACTERISTICS. D-DIMER IS NOT A STANDARDIZED ANALYTE AND RESULTS GENERATED USING DIFFERENT D-DIMER ASSAYS ARE NOT NECESSARILY IDENTICAL DUE TO FACTORS SUCH AS (BUT NOT LIMITED TO): REACTIVITY/SPECIFICITY OF DIFFERENT ANTIBODIES. EPITOPE EXPRESSION DURING FIBRIN FORMATION AND DEGRADATION. HETEROGENEITY OF THE FIBRIN DEGRADATION PRODUCTS IN PLASMA. CALIBRATOR MATERIAL. VARIATION IN OPTICAL DETECTION ABILITY BETWEEN DIFFERENT INSTRUMENTS. ASSAY FORMATS (LATEX BEAD SIZE AND REQUIRED WAVELENGTHS). INTERFERENCE BY OTHER ANALYTES (E.G. RHEUMATOID FACTOR (RF), MOUSE MONOCLONAL ANTIBODIES. THE INVESTIGATION COULD NOT IDENTIFY A PRODUCT PROBLEM. THIS EVENT OCCURRED IN (B)(6). UDI NUMBER = (B)(4).

Description of Event or Problem · 1

THE INITIAL REPORTER STATED THEY RECEIVED DISCREPANT RESULTS FOR TWO SAMPLES COLLECTED FROM THE SAME PATIENT AND TESTED WITH D-DI TINA-QUANT D-DIMER GEN. 2 ON A COBAS 6000 C (501) MODULE. NO INCORRECT RESULTS WERE REPORTED OUTSIDE OF THE LABORATORY. THE REPORTER STATED THAT SINCE THE PATIENT WAS RECOVERING, WAS STABLE, AND IL6 VALUES DROPPED FROM A PREVIOUS VALUE OF 9.76 (NO UNITS PROVIDED) TO 2.15, IT WAS EXPECTED THAT D-DIMER VALUES WOULD DROP AS WELL. THE FIRST SAMPLE RESULTED IN A D-DIMER VALUE OF 4006 NG/ML WHEN TESTED ON THE C 501 ANALYZER. THE SAMPLE WAS REPEATED ON A VIDAS ANALYZER, RESULTING IN A VALUE OF 278.39 NG/ML. THE SECOND SAMPLE RESULTED IN A D-DIMER VALUE OF 3848 NG/ML WHEN TESTED ON THE C 501 ANALYZER. THE SAMPLE WAS REPEATED ON A VIDAS ANALYZER, RESULTING IN A VALUE OF 284.81. THIS SAMPLE WAS THEN DILUTED 1:5 AND REPEATED ON THE C 501 ANALYZER, RESULTING IN A VALUE OF 7049 NG/ML ON (B)(6) 2021. THE SAMPLE WAS ALSO DILUTED 1:10 AND REPEATED ON THE C 501 ANALYZER, RESULTING IN A VALUE OF 6904 NG/ML ON (B)(6) 2021. THE THIRD SAMPLE RESULTED IN A D-DIMER VALUE OF 3709 NG/ML WHEN TESTED ON THE C 501 ANALYZER ON (B)(6) 2021. WHEN REPEATED ON A VIDAS ANALYZER, THIS SAMPLE RESULTED IN A VALUE OF 346.36 NG/ML. THE SAMPLE WAS ALSO REPEATED ON A HORIBA PENTRA 400 SYSTEM, RESULTING IN A VALUE OF 294 NG/ML. THE SERIAL NUMBER OF THE C 501 ANALYZER IS (B)(4).

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
575422 D-DIMER FIBRIN SPLIT PRODUCTS GHH ROCHE DIAGNOSTICS NA 509145

Patients

Seq Age Sex Outcome Treatment
1 CROCIN ("SOS ON FEVER").| DOXY TABLET (ONE TAB AFTER BREAKFAST FOR 5 DAYS).| LUPENOX INJECTION.| PAN (BEFORE BREAKFAST FOR 10 DAYS).| REMDESIVIR INJECTION.| VITAMIN C TABLET (ONE AT 8 A.M., ONE AT 8 P.M.).| ZINC TABLET (ONE AT 8 A.M.).