FDA Adverse Event Injury Summary report: N

UNK MAMMARY IMPLANT

MDR report key: 11668940 · Received April 15, 2021

Report

Report Number
9617229-2021-06185
Event Type
Injury
Date Received
April 15, 2021
Date of Event
January 1, 2021
Report Date
April 13, 2021
Manufacturer
UNKNOWN MANUFACTURER
Product Code
FWM
PMA / PMN Number
P990074
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
NE, US
Reporter Occupation
PHYSICIAN

Narratives

Additional Manufacturer Narrative · 1

ARTICLE CITATION: AMADOR, CATALINA, FELDMAN, ANDREW. HOW I DIAGNOSE ANAPLASTIC LARGE CELL LYMPHOMA. AMERICAN JOURNAL OF CLINICAL PATHOLOGY. 2021; 479-497. (B)(4). THE EVENTS OF LYMPHOMA - ALCL, LYMPHADENOPATHY, AND LUMP/NODULE ARE PHYSIOLOGICAL COMPLICATIONS AND ANALYSIS OF THE DEVICE GENERALLY DOES NOT ASSIST ALLERGAN IN DETERMINING A PROBABLE CAUSE FOR THESE EVENTS. FURTHER INFORMATION FROM THE REPORTER REGARDING EVENT, PRODUCT, OR PATIENT DETAILS HAS BEEN REQUESTED. NO ADDITIONAL INFORMATION IS AVAILABLE AT THIS TIME. REASON FOR REOPERATION: CD30+, ALK- BIA-ALCL; RIGHT AXILLARY LYMPHADENOPATHY; NODULARITY; ASSOCIATED MASS IN THE RIGHT CAPSULECTOMY SPECIMEN.

Description of Event or Problem · 1

THROUGH JOURNAL ARTICLE ¿HOW I DIAGNOSE ANAPLASTIC LARGE CELL LYMPHOMA¿ AUTHORS REPORT A (B)(6)-YEAR-OLD PATIENT WHO UNDERWENT EXCISIONAL LYMPH NODE BIOPSY FOR RIGHT AXILLARY LYMPHADENOPATHY WITHOUT OTHER CLINICAL HISTORY PROVIDED. SECTIONS OF THE LYMPH NODE SHOWED AN ATYPICAL LYMPHOID INFILTRATE WITH A SINUSOIDAL GROWTH PATTERN COMPOSED OF LARGE PLEOMORPHIC CELLS, INCLUDING HALLMARK CELLS WITH RENIFORM NUCLEI. THE NEOPLASTIC CELLS WERE POSITIVE FOR CD30 AND NEGATIVE FOR ALK. THE CASE WAS SIGNED OUT AS ALK-NEGATIVE ALCL. SUBSEQUENTLY, THE PATIENT WAS EVALUATED BY A HEMATOLOGIST/ ONCOLOGIST WHO RAISED CONCERN ABOUT BREAST IMPLANT-ASSOCIATED ALCL (BIA-ALCL), AS THE PATIENT HAD A HISTORY OF BILATERAL MASTECTOMY WITH IMPLANT PLACEMENT FOR BREAST CARCINOMA 10 YEARS PREVIOUSLY AND HAD NOTED HARDNESS AND SWELLING OF THE RIGHT BREAST FOR THE PAST 6 MONTHS. PET SCAN SHOWED NO DISEASE BEYOND THE RIGHT AXILLARY REGION AND BREAST. THE BREAST IMPLANTS WERE REMOVED AND SHOWED GROSS ADHESIONS, NODULARITY, AND AN ASSOCIATED MASS IN THE RIGHT CAPSULECTOMY SPECIMEN. HISTOLOGIC SECTIONS SHOWED LARGE PLEOMORPHIC CELLS WITH MORPHOLOGY AND PHENOTYPE SIMILAR TO THOSE SEEN IN THE LYMPH NODE EXCISION. GIVEN THE ADDITIONAL FINDINGS, THE FINAL DIAGNOSIS WAS AMENDED TO BIAALCL WITH EXTENSION TO THE REGIONAL LYMPH NODES. THE MANUFACTURER OF THE DEVICE IS UNKNOWN. AFFECTED SIDE IS RIGHT. THE DEVICE HAS BEEN EXPLANTED.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
571365 UNK MAMMARY IMPLANT PROSTHESIS, BREAST, INFLATABLE, INTERNAL, SALINE FWM UNKNOWN MANUFACTURER NI

Patients

Seq Age Sex Outcome Treatment
1 64 YR Life Threatening| R