FDA Adverse Event Injury Summary report: N

CARDIOQUIP MODULAR COOLER HEATER

MDR report key: 11667537 · Received April 14, 2021

Report

Report Number
3007899424-2021-00006
Event Type
Injury
Date Received
April 14, 2021
Date of Event
February 7, 2021
Report Date
June 3, 2022
Manufacturer
CARDIOQUIP, LLC
Product Code
DWC
PMA / PMN Number
K102147
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
MA, US
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

THE MANUFACTURER IS REPORTING THE FOLLOWING COMPLAINT AFTER A VOLUNTARY REVIEW OF ALL COMPLAINTS (REPORTABLE OR NOT) SINCE 2016. THIS REPORT IS BEING FILED NOW, AFTER BEING SCRUTINIZED UNDER A NEWLY REVISED RISK MATRIX, RECENTLY ADOPTED AFTER INSPECTION. THE DEVICE WAS FOUND TO BE CONTAMINATED WITH THE SAME BACTERIA THAT CAUSED INFECTION IN THE PATIENT (BURKHOLDERIA). DUE TO LACK OF ACCESS TO THE DEVICE, AN INVESTIGATION ON OTHER SIMILAR DEVICES AT THE LOCATION HAD TO BE PERFORMED. THE TEST CAN CONCLUDE THAT ALL OF THE UNITS WOULD BE CONTAMINATED BUT UNABLE TO DECIDE ON WHETHER OR NOT THE DEVICE CAUSED THE ADVERSE EVENT DUE TO THE LIMITATIONS OF THE INVESTIGATION PERFORMED AT THE FACILITY, CARDIOQUIP IS ALSO UNABLE TO RULE OUT THE POSSIBILITY OF A UNIFIED SOURCE OF CONTAMINATION FOR BOTH THE HEATER COOLER AND THE PATIENT, FOR EXAMPLE, A CONTAMINATED WATER SOURCE.

Description of Event or Problem · 0

THE CUSTOMER REPORTED THAT THE DEVICE, DIS150, DISPOSABLE MARKED SPRING TIP GUIDEWIRE, WAS BEING USED DURING AN UNKNOWN PROCEDURE ON (B)(6) 2022 WHEN IT WAS REPORTED ¿CLEANGUIDE DISPOSABLE GUIDEWIRES AND THE BASE OF THE SPRING TIP COMPLETELY BENT. THEY TOOK ANOTHER GUIDEWIRE AND IT BENT AT THE SAME POINT JUST AS EASILY. NO HARM TO THE PATIENT. NO DELAYS. IT WAS NOTICED AT THE END OF THE PROCEDURE WHEN IT WAS REMOVED. STAFF DID NOT ¿FEEL¿ ANY RESISTANCE, OR THAT IT ¿GOT HUNG¿ ON ANYTHING DURING THE PROCEDURE.¿. THE PROCEDURE WAS COMPLETED AS PLANNED WITH NO REPORT OF INJURY, MEDICAL INTERVENTION, OR HOSPITALIZATION FOR THE PATIENT AND HAVING USED TWO DEVICES WITH THE SAME LOT NUMBER. THIS REPORT IS BEING RAISED ON THE BASIS OF MALFUNCTION WITH POTENTIAL FOR INJURY UPON REOCCURRENCE.

Additional Manufacturer Narrative · 1

(B)(6) SUBMITTED A USER FACILITY REPORT 2201100000-2021-8005. CARDIOQUIP FOLLOWED UP WITH BWH TO REQUEST THE DEVICE BE RETURNED TO CARDIOQUIP FOR INVESTIGATION. BWH DID ALLOW CARDIOQUIP'S PERSONNEL TO COME ONSITE BUT PERSONNEL WERE NOT GIVEN ACCESS TO THE DEVICE. ADDITIONALLY, AT THE TIME OF THIS REPORT, THE DEVICE HAS NOT BEEN RETURNED TO CARDIOQUIP FOR INVESTIGATION AND ANY RESULTS FROM TESTING PERFORMED ON THE DEVICE BY BWH HAVE NOT BEEN SUPPLIED TO CARDIOQUIP. CARDIOQUIP IS IN CONTINUOUS DIALOGUE WITH BWH REGARDING THEIR INVESTIGATION AND POTENTIAL FOR THE DEVICE TO BE RETURNED TO CARDIOQUIP AT A LATER DATE.

Description of Event or Problem · 1

HOLD FOR ADRIAN 07.15.2021DESCRIBE THE EVENT OR PROBLEM: ADDITIONAL DETAILS FOR THIS PATIENT: THE PATIENT WAS INITIALLY CANNULATED FOR ECMO FOR RESPIRATORY FAILURE. THE PATIENT WAS FOUND TO HAVE POSITIVE SPUTUM CULTURES FOR CUPRIAVIDUS. THE PATIENT REMAINS ON ECMO SUPPORT. THE ASSOCIATED USER FACILITY REPORT IS MDR 2201100000-2021-8005.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
564576 CARDIOQUIP MODULAR COOLER HEATER CARDIOPULMONARY BYPASS DEVICE DWC CARDIOQUIP, LLC MCH-1000 (M)

Patients

Seq Age Sex Outcome Treatment
1 23 YR Female Hospitalization| R