AVANTAGE RELOAD CUP TI HA S44
Report
- Report Number
- 3006946279-2021-00028
- Event Type
- Injury
- Date Received
- March 31, 2021
- Date of Event
- July 28, 2020
- Report Date
- May 28, 2021
- Manufacturer
- BIOMET FRANCE S.A.R.L.
- Product Code
- KWA
- PMA / PMN Number
- N/A
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- FR
- Reporter Occupation
- PHYSICIAN
Narratives
(B)(4). THE PRODUCT ANALYSIS CAN'T BE PERFORMED AS THE PRODUCT WAS NOT RETURNED (REMAINS IMPLANTED). THE DEVICE MANUFACTURING QUALITY RECORD INDICATES THAT THE RELEASED PRODUCT MET ALL REQUIREMENTS TO PERFORM AS INTENDED. RESULTS FROM MICROBIOLOGY ANALYSIS WERE RECEIVED, AND ALLOWED TO CONFIRM THE REPORTED INFECTION. ACCORDING TO THESE RESULTS, THE REPORTED EVENT WAS DUE TO BACTERIAL INFECTION TO STAPHYLOCOCCUS EPIDERMIDIS, WHICH IS A NORMAL COLONIZER OF THE SKIN. COMPLAINT EXTRACT WAS DONE REGARDING MEDICAL INFECTION: 1 COMPLAINT (1 PRODUCT), THIS ONE INCLUDED, HAS BEEN RECORDED ON AVANTAGE RELOAD CUP TI HA S44, REFERENCE (B)(4), FROM (B)(6) 2018 TO (B)(6) 2021. 1 COMPLAINT (1 PRODUCT), THIS ONE INCLUDED, HAS BEEN RECORDED ON AVANTAGE RELOAD CUP TI HA S44, REFERENCE (B)(4), BATCH 0001219576, SINCE EVER. INVESTIGATION RESULTS CONCLUDED THAT THE REPORTED EVENT WAS DUE TO BACTERIAL INFECTION TO STAPHYLOCOCCUS EPIDERMIDIS, WHICH IS A NORMAL COLONIZER OF SKIN. THERE IS NO EVIDENCE THAT THE EVENT IS RELATED TO THE PRODUCT. THE COMPLAINT IS CLOSED BUT COULD BE REOPENED IF NEW INFORMATION IS RECEIVED LATER. IF ANY FURTHER INFORMATION IS FOUND WHICH WOULD CHANGE OR ALTER ANY CONCLUSIONS OR INFORMATION, A SUPPLEMENTAL WILL BE FILED ACCORDINGLY. ZIMMER BIOMET WILL CONTINUE TO MONITOR FOR TRENDS.
IT WAS REPORTED THAT THE PATIENT WAS RECEIVED ON (B)(6) 2020 AT THE CLINIC AND UNDERWENT ON (B)(6) 2020 A CLEANING AND WASHING OF THE JOINT FOLLOWING A BACTERIAL INFECTION TO STAPHYLOCOCCUS EPIDERMIDIS, WHICH IS A NORMAL COLONIZER OF SKIN.
(B)(4). REPORT SOURCE, FOREIGN - EVENT OCCURRED IN (B)(6). LIST OF ASSOCIATED DEVICES: AVANTAGE INLAY S44 / 22,2 ; ITEM # P0560044; LOT # 0001439499; MANUFACTURED BY ZB VALENCE. EXCEPTION STD STEM LEFT SIZE 1; ITEM #PS125Y01; LOT #0001270155; MANUFACTURED BY ZB VALENCE. COCR FM HD D22,2/ 12-14/ +2/ L ; ITEM #P0206L22; LOT #J6382918; MANUFACTURED BY ZB VALENCE. THE DEVICE MANUFACTURING QUALITY RECORDS ALL INDICATE THAT THE RELEASED PRODUCTS MET ALL REQUIREMENTS TO PERFORM AS INTENDED. THE INVESTIGATION IS IN PROGRESS. ONCE THE INVESTIGATION HAS BEEN COMPLETED, A FOLLOW-UP MDR WILL BE SUBMITTED. IF ANY FURTHER INFORMATION IS FOUND WHICH WOULD CHANGE OR ALTER ANY CONCLUSIONS OR INFORMATION, A SUPPLEMENTAL WILL BE FILED ACCORDINGLY.
IT WAS REPORTED THAT THE PATIENT WAS RECEIVED ON (B)(6) 2020 AT THE CLINIC AND UNDERWENT ON (B)(6) 2020 A CLEANING AND WASHING OF THE JOINT FOLLOWING A BACTERIAL INFECTION TO STAPHYLOCOCCUS EPIDERMIDIS, WHICH IS A NORMAL COLONIZER OF SKIN.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 492773 | AVANTAGE RELOAD CUP TI HA S44 | ACETABULAR SHELL | KWA | BIOMET FRANCE S.A.R.L. | 0001219576 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 83 YR | Hospitalization| R | ASSOCIATED DEVICES LISTED IN SECTION H10.| ASSOCIATED DEVICES LISTED IN SECTION H10. |