PROLENE POLYPROPYLENE SUTURE UNKNOWN PRODUCT
Report
- Report Number
- 2210968-2021-02566
- Event Type
- Death
- Date Received
- March 19, 2021
- Date of Event
- June 1, 2011
- Report Date
- March 3, 2021
- Manufacturer
- ETHICON INC.
- Product Code
- GAW
- PMA / PMN Number
- K133356
- Removal / Correction Number
- N/A
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- IN
- Reporter Occupation
- OTHER
Narratives
PRODUCT COMPLAINT (B)(4). DATE SENT TO THE FDA: 03/19/2021. (B)(4) ¿ DEVICE NOT RETURNED. THIS REPORT IS RELATED TO A JOURNAL ARTICLE; THEREFORE, NO PRODUCT WILL BE RETURNED FOR ANALYSIS AND THE BATCH HISTORY RECORDS CANNOT BE REVIEWED AS THE LOT NUMBER HAS NOT BEEN PROVIDED. THE SINGLE COMPLAINT WAS REPORTED WITH MULTIPLE EVENTS. THERE ARE NO ADDITIONAL DETAILS, DEMOGRAPHICS REGARDING THE ADDITIONAL EVENTS CITATION: LIVER TRANSPLANTATION. 2011 JUN; CONFERENCE: 2011 JOINT INTERNATIONAL CONGRESS OF ILTS, ELITA, AND LICAGE. VALENCIA SPAIN. CONFERENCE PUBLICATION: (VAR.PAGINGS). 17 (SUPPL. 1) :S240. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL REPORT, A FOLLOW-UP REPORT WILL BE FILED AS APPROPRIATE. ADVERSE EVENTS CASES SUBMITTED VIA 2210968-2021-02565. MORTALITY CASES SUBMITTED.
TITLE: INCIDENCE OF HEPATIC ARTERY THROMBOSIS IN 522 CONSECUTIVE LIVING DONOR LIVER TRANSPLANTS. AUTHORS: MEHTA N.N; VARMA V; GOVINDASAMY M; KUMARAN V; MOHANKA R; RASTOGI A; NUNDY S; SOIN A. CITATION: LIVER TRANSPLANTATION. 2011 JUN; CONFERENCE: 2011 JOINT INTERNATIONAL CONGRESS OF ILTS, ELITA, AND LICAGE. VALENCIA SPAIN. CONFERENCE PUBLICATION: (VAR.PAGINGS). 17 (SUPPL. 1) :S240. THE AIM OF OUR PROSPECTIVE STUDY WAS TO DETERMINE INCIDENCE, TREATMENT AND CLINICAL OUTCOME OF HEPATIC ARTERY THROMBOSIS (HAT), IN PATIENTS UNDERGOING LIVING DONOR LIVING TRANSPLANTATION (LDLT). FIVE HUNDRED TWENTY-TWO CONSECUTIVE LDLT RECIPIENTS OPERATED BETWEEN JANUARY 2001 TILL MARCH 2010. DURING THE PROCEDURE, HEPATIC ARTERIAL ANASTOMOSES WAS PERFORMED WITH 7-0 PROLENE INTERRUPTED SUTURES (ETHICON) END TO END UNDER 2.5X SURGICAL LOUPE MAGNIFICATION. REPORTED COMPLICATIONS INCLUDED HAT (N=5 MALES, 3=FEMALES; MEAN AGE=44 YEARS, AGE RANGE=9 MONTHS ¿ 61 YEARS) IN WHICH 6 PATIENTS WERE RE-EXPLORED AND GRAFT ARTERIAL FLOW WAS SUCCESSFULLY RE-ESTABLISHED IN 5; REVASCULARIZATION WAS UNSUCCESSFUL (N=1) WHICH REQUIRED RE-TRANSPLANTATION; EXTENSIVE THROMBOSIS EXTENDING WITHIN THE GRAFT (N=1) WHICH THE PATIENT WAS TAKEN UP FOR RE-TRANSPLANTATION; POST-OPERATIVE MORTALITY INCLUDED SUCCUMBED TO SEPSIS (N=3) IN WHICH 2 PATIENTS IN THE POSTOPERATIVE PERIOD AND 1 DUE TO DELAYED BILIARY COMPLICATIONS. IN CONCLUSION, METICULOUS SURGICAL TECHNIQUE FOR HEPATIC ARTERY RECONSTRUCTION PREVENTS HAT. URGENT RE-VASCULARIZATION AND/OR RE-TRANSPLANTATION IS SUCCESSFUL AND SHOULD BE ATTEMPTED FOR HAT.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 421118 | PROLENE POLYPROPYLENE SUTURE UNKNOWN PRODUCT | SUTURE, NONABSORBABLE, SYNTHETIC, POLYPROPYLENE | GAW | ETHICON INC. |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Death |