FDA Adverse Event Injury Summary report: N

PROLENE POLYPROPYLENE SUTURE UNKNOWN PRODUCT

MDR report key: 11530653 · Received March 19, 2021

Report

Report Number
2210968-2021-02565
Event Type
Injury
Date Received
March 19, 2021
Date of Event
June 1, 2011
Report Date
March 3, 2021
Manufacturer
ETHICON INC.
Product Code
GAW
PMA / PMN Number
K133356
Removal / Correction Number
N/A
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
IN
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 1

PRODUCT COMPLAINT (B)(4). (B)(4). DEVICE NOT RETURNED. THIS REPORT IS RELATED TO A JOURNAL ARTICLE; THEREFORE, NO PRODUCT WILL BE RETURNED FOR ANALYSIS AND THE BATCH HISTORY RECORDS CANNOT BE REVIEWED AS THE LOT NUMBER HAS NOT BEEN PROVIDED. THE SINGLE COMPLAINT WAS REPORTED WITH MULTIPLE EVENTS. THERE ARE NO ADDITIONAL DETAILS, DEMOGRAPHICS REGARDING THE ADDITIONAL EVENTS. CITATION: LIVER TRANSPLANTATION. 2011 JUN; CONFERENCE: 2011 JOINT INTERNATIONAL CONGRESS OF ILTS, ELITA, AND LICAGE. VALENCIA SPAIN. CONFERENCE PUBLICATION: (VAR.PAGINGS). 17 (SUPPL. 1) :S240. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL REPORT, A FOLLOW-UP REPORT WILL BE FILED AS APPROPRIATE. ADVERSE EVENTS CASES SUBMITTED VIA 2210968-2021-02565. MORTALITY CASES SUBMITTED VIA 2210968-2021-02566.

Description of Event or Problem · 1

TITLE: INCIDENCE OF HEPATIC ARTERY THROMBOSIS IN 522 CONSECUTIVE LIVING DONOR LIVER TRANSPLANTS. AUTHORS: MEHTA N.N; VARMA V; GOVINDASAMY M; KUMARAN V; MOHANKA R; RASTOGI A; NUNDY S; SOIN A. CITATION: LIVER TRANSPLANTATION. 2011 JUN; CONFERENCE: 2011 JOINT INTERNATIONAL CONGRESS OF ILTS, ELITA, AND LICAGE. VALENCIA SPAIN. CONFERENCE PUBLICATION: (VAR.PAGINGS). 17 (SUPPL. 1) :S240. THE AIM OF OUR PROSPECTIVE STUDY WAS TO DETERMINE INCIDENCE, TREATMENT AND CLINICAL OUTCOME OF HEPATIC ARTERY THROMBOSIS (HAT), IN PATIENTS UNDERGOING LIVING DONOR LIVING TRANSPLANTATION (LDLT). FIVE HUNDRED TWENTY-TWO CONSECUTIVE LDLT RECIPIENTS OPERATED BETWEEN JANUARY 2001 TILL MARCH 2010. DURING THE PROCEDURE, HEPATIC ARTERIAL ANASTOMOSES WAS PERFORMED WITH 7-0 PROLENE INTERRUPTED SUTURES (ETHICON) END TO END UNDER 2.5X SURGICAL LOUPE MAGNIFICATION. REPORTED COMPLICATIONS INCLUDED HAT (N=5 MALES, 3=FEMALES; MEAN AGE=44 YEARS, AGE RANGE=9 MONTHS  61 YEARS) IN WHICH 6 PATIENTS WERE RE-EXPLORED AND GRAFT ARTERIAL FLOW WAS SUCCESSFULLY RE-ESTABLISHED IN 5; REVASCULARIZATION WAS UNSUCCESSFUL (N=1) WHICH REQUIRED RE-TRANSPLANTATION; EXTENSIVE THROMBOSIS EXTENDING WITHIN THE GRAFT (N=1) WHICH THE PATIENT WAS TAKEN UP FOR RE-TRANSPLANTATION. IN CONCLUSION, METICULOUS SURGICAL TECHNIQUE FOR HEPATIC ARTERY RECONSTRUCTION PREVENTS HAT. URGENT RE-VASCULARIZATION AND/OR RE-TRANSPLANTATION IS SUCCESSFUL AND SHOULD BE ATTEMPTED FOR HAT.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
420520 PROLENE POLYPROPYLENE SUTURE UNKNOWN PRODUCT SUTURE, NONABSORBABLE, SYNTHETIC, POLYPROPYLENE GAW ETHICON INC.

Patients

Seq Age Sex Outcome Treatment
1 Required Intervention