FDA Adverse Event Summary report: N

LEECHES

MDR report key: 11470 · Received February 7, 1994

Report

Report Number
MW4000273
Date Received
February 7, 1994
Date of Event
September 24, 1992
Report Date
October 8, 1992
Manufacturer
LEECHES USA LTD
Report Source
Voluntary report
Reporter Occupation
INVALID DATA

Narratives

Description of Event or Problem · 1

ON 9/24/92, LEECH TREATMENT WAS INITIATED ON A PT FOLLOWING RADICAL CANCER SURGERY WHICH INVOLVED REMOVAL AND REPLACEMENT OF THE RIGHT EAR. THE PT DEVELOPED SEPSIS, WHICH IS FELT COULD HAVE BEEN CAUSED BY THE WATER THE LEECHES WERE STORED IN SINCE THE SEPSIS COULD NOT BE ATTRIBUTED TO ANY OTHER SOURCE. CULTURED FROM THE WATER WAS AEROMONAS HYDROPHILA, WHICH IS NORMAL FLORA FOR LEECHES. ALSO CULTURED WERE MARINE ORGANISMS, CHROMOBACTER VIOLACEUM AND VIBRIO ALGINOLYTICUS WHICH ARE NOT ASSOCIATED WITH LEECHES AND ARE UNUSUAL ORGANISMS FOR THE AREA. THE PT'S BLOOD CULTURE WAS NEGATIVE WHICH THE PHYSICIAN FEELS WAS DUE TO THE FACT THAT HE WAS ON INNUMERABLE ANTIBIOTICS.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1 LEECHES LEECHES USA LTD NA

Patients

Seq Age Sex Outcome Treatment
1 *