PROLENE POLYPROPYLENE SUTURE UNKNOWN PRODUCT
Report
- Report Number
- 2210968-2021-02228
- Event Type
- Injury
- Date Received
- March 10, 2021
- Date of Event
- May 20, 2018
- Report Date
- March 1, 2021
- Manufacturer
- ETHICON INC.
- Product Code
- GAW
- PMA / PMN Number
- K133356
- Removal / Correction Number
- N/A
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- BR
- Reporter Occupation
- OTHER
Narratives
DATE SENT TO THE FDA: 03/10/2021. ADDITIONAL INFORMATION: ARTICLE ATTACHED. THIS REPORT IS BEING SUBMITTED PURSUANT TO THE PROVISIONS OF 21 CFR, PART 803. THIS REPORT MAY BE BASED ON INFORMATION WHICH HAS NOT BEEN INVESTIGATED OR VERIFIED PRIOR TO THE REQUIRED REPORTING DATE. THIS REPORT DOES NOT REFLECT A CONCLUSION BY ETHICON INC, OR ITS EMPLOYEES THAT THE REPORT CONSTITUTES AN ADMISSION THAT THE PRODUCT, ETHICON INC, OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE POTENTIAL EVENT DESCRIBED IN THIS REPORT. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL REPORT, A FOLLOW-UP REPORT WILL BE FILED AS APPROPRIATE.
PRODUCT COMPLAINT # (B)(4). (B)(4). THIS REPORT IS RELATED TO A JOURNAL ARTICLE; THEREFORE, NO PRODUCT WILL BE RETURNED FOR ANALYSIS AND THE BATCH HISTORY RECORDS CANNOT BE REVIEWED AS THE LOT NUMBER HAS NOT BEEN PROVIDED. THE SINGLE COMPLAINT WAS REPORTED WITH MULTIPLE EVENTS. THERE ARE NO ADDITIONAL DETAILS REGARDING THE ADDITIONAL EVENTS. CITATION: THE JOURNAL OF UROLOGY E903: PEDIATRIC UROLOGY V09-02 / VOL. 199, NO. 4S, SUPPLEMENT, SUNDAY, MAY 20, 2018. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL REPORT, A FOLLOW-UP REPORT WILL BE FILED AS APPROPRIATE.
TITLE: ABDOMINOPLASTY WITHOUT OSTEOTOMIES USING GROIN FLAPS TO CLOSE THE ABDOMINAL WALL DEFECT IN THE MANAGEMENT OF EXSTROPHY-EPISPADIAS COMPLEX. THE AIM OF THIS STUDY IS TO DESCRIBE THE GROIN FLAP TECHNIQUE TO CLOSE THE ABDOMINAL WALL OF CHILDREN WITH EXSTROPHY-EPISPADIA COMPLEX WITHOUT OSTEOTOMY AND WITHOUT RADICAL SOFT TISSUE MOBILIZATION. DURING THE LAST 30 YEARS, GROIN FLAP WAS APPLIED TO 128 PATIENTS WITH BLADDER EXSTROPHY BUT ONLY 44 HAD REGULAR FOLLOW UPS. GROIN FLAPS WERE MADE OF THE RECTUS ANTERIOR APONEUROSES ROTATED MEDIALLY, FLIPPED OVER, AND SUTURED WITH PROLENE (ETHICON) SUTURES TO CLOSE THE DEFECT. ONE PATIENT HAD COMPLETE WOUND DEHISCENCE (N=1) THAT NEEDED ANOTHER RECONSTRUCTION AND FOUR PATIENTS PRESENTED ABDOMINAL HERNIAS (N=4) THAT NEEDED SURGICAL MANAGEMENT. ONE-STAGED RECONSTRUCTION USING GROIN FLAPS HAS ADVANTAGES OVER THE TRADITIONAL APPROACHES TO BLADDER EXSTROPHY. IT REDUCES THE SURGICAL STEPS AND FACILITATES THE CLOSURE OF THE ABDOMINAL WALL WITHOUT THE NEED OF OSTEOTOMIES AND CONSEQUENT IMMOBILIZATION DURING THE POSTOPERATIVE PERIOD. IT IS FEASIBLE AT ANY AGE AND CAN BE ALSO VERY USEFUL AS A RESCUE TECHNIQUE EVEN AFTER PREVIOUS FAILED PROCEDURES. FINALLY, IT MINIMIZES THE NUMBER OF SURGERIES.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 348480 | PROLENE POLYPROPYLENE SUTURE UNKNOWN PRODUCT | SUTURE, NONABSORBABLE, SYNTHETIC, POLYPROPYLENE | GAW | ETHICON INC. |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Required Intervention |