PROLENE POLYPROPYLENE SUTURE UNKNOWN PRODUCT
Report
- Report Number
- 2210968-2021-02145
- Event Type
- Injury
- Date Received
- March 9, 2021
- Date of Event
- April 1, 2015
- Report Date
- February 26, 2021
- Manufacturer
- ETHICON INC.
- Product Code
- GAW
- PMA / PMN Number
- K133356
- Removal / Correction Number
- N/A
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- US
- Reporter Occupation
- OTHER
Narratives
(B)(4). THIS REPORT IS RELATED TO A JOURNAL ARTICLE; THEREFORE, NO PRODUCT WILL BE RETURNED FOR ANALYSIS AND THE BATCH HISTORY RECORDS CANNOT BE REVIEWED AS THE LOT NUMBER HAS NOT BEEN PROVIDED. CITATION: JOURNAL OF UROLOGY. 2015 APR; CONFERENCE: 2015 ANNUAL MEETING OF THE AMERICAN UROLOGICAL ASSOCIATION, AUA. NEW ORLEANS, LA UNITED STATES. CONFERENCE PUBLICATION: (VAR.PAGINGS). 193 (4 SUPPL. 1) :E471-E472.
TITLE: LAPAROSCOPIC INTRA-ABDOMINAL PATENT PROCESS VAGINALIS LIGATION IN PEDIATRIC UROLOGY PRACTICE AUTHOR: BARADARAN N., WOOD C., PRASAD M., STEC A. THIS STUDY PRESENTS THE AUTHORS¿ EXPERIENCE, OUTCOMES AND COMPLICATIONS USING LAPAROSCOPIC INTRAABDOMINAL PATENT PROCESS VAGINALIS LIGATION (LIPPL). BETWEEN 2012 AND 2014, 84 PATIENTS (1 FEMALE) WITH MEDIAN AGE OF 24 (1-216) MONTHS UNDERWENT LIPPL. THE PATENT PROCESSUS VAGINALIS (PPV) IS IDENTIFIED AND INTERNAL RING IS LIGATED USING PERCUTANEOUS INSERTION OF SPINAL NEEDLE ABOVE THE INTERNAL RING. THE NEEDLE IS PASSED LATERALLY AND A LOOP OF A 2-0 OR 3-0 PROLENE SUTURE (ETHICON) IS PASSED INTO THE ABDOMEN. THE NEEDLE IS WITHDRAWN, REINSERTED AND A TAIL OF THE SUTURE IS PASSED INTO THE ABDOMEN. THERE WERE NO INTRAOPERATIVE COMPLICATIONS. DURING FOLLOW-UP, PATIENTS HAD RESIDUAL NON-COMMUNICATION HYDROCELES (N=2), SUTURE GRANULOMA REQUIRING EXCISION (N=1) AND A MINOR TESTICULAR ASCENT (N=1). THE LIPPL TECHNIQUE ADHERES TO THE SAME PRINCIPLES OF OPEN INGUINAL HERNIA REPAIR BY LIGATING THE OPEN INTERNAL RING. THIS OUTPATIENT PROCEDURE HAS A LOW COMPLICATION RATE AND MINIMAL RISK OF RECURRENCE. IT PROVIDES PATIENTS WITH THE BENEFITS OF LAPAROSCOPIC SURGERY INCLUDING ABILITY TO EVALUATE THE CONTRALATERAL INGUINAL RING, BARELY VISIBLE SCARS, AND SHORT RECOVERY TIME.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 340706 | PROLENE POLYPROPYLENE SUTURE UNKNOWN PRODUCT | SUTURE, NONABSORBABLE, SYNTHETIC, POLYPROPYLENE | GAW | ETHICON INC. |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Required Intervention |